Grand Junction building inspections
VerifiedInspection sequence, scheduling, and re-inspection fees for building permits in Grand Junction, Colorado.
Verified 2026-07-03 · Source
How to schedule
Inspections are requested through the building department below.
- Address
- 200 S. Spruce Street, Grand Junction, CO 81501 (mailing: PO Box 20,000-5005, Grand Junction, CO 81502-5001)
- Phone
- (970) 244-1631
- Office hours
- Monday - Friday, 8:00 a.m.-5:00 p.m.; permit issuance after 4:30 p.m. is on a limited basis and no multiple permits are issued after 4:30 p.m. (Source: Mesa County Building Department Fees page)
- Website
- Official site
Published scheduling rules
- Inspections can be scheduled via the Mesa County Customer Portal, by phone (970-256-1564, IVR system), or by text (text SCHEDULE to 844-987-4628). (Residential Building Permit (New Construction))
- Inspections are scheduled in the morning during hot weather where possible, to avoid shingle damage and protect inspector safety. (Re-Roofing Permit)
Inspection sequence
Applies to: Residential Building Permit (New Construction)
- 1
Foundation (Footer/Stem Wall or Monoslab)
Per Mesa County Residential Inspection Request Guidelines: 100-Footer, 120-Setbacks, 475-UFER (footer/stem wall); or 104-Slab, 120-Setbacks, 475-UFER for monoslab. Engineer-inspected foundations require a letter by frame inspection.
- 2
Underground Utilities
224-Sewer, 226-Waterline; in-trench 226-Waterline, 340-Gas Piping, 466-Underground where applicable
- 3
Rough-In (Framing, Electrical, Plumbing, Mechanical, Insulation)
105-Floor Framing (if applicable); 462-Electrical (before insulation); 106-Framing, 222-Plumbing, 346-Venting, 348-Mech Duct, 350-Gas Fireplace (if applicable); 115-Stucco Lath; 108-Insulation
- 4
Gas Appliances
340-Gas Piping & Test, 342-Boiler/Furnace, 344-Water Heater
- 5
Final
116-Building, 232-Plumbing, 356-Mechanical, 476-Electrical. Zoning, septic final, and floodplain sign-off (where applicable) are required to be complete before a Certificate of Occupancy is issued.
Applies to: Plumbing Permit
- 1
Underground/In-Slab Plumbing
220-Underground Plumbing, 470-In Slab Rough-In; 224-Sewer and 226-Waterline for underground utility connections, per Mesa County Residential Inspection Request Guidelines
- 2
Rough-In Plumbing
222-Plumbing rough-in inspection, typically bundled with framing (106), venting (346), and mechanical duct (348) inspections
- 3
Gas Piping
340-Gas Piping & Test; 342-Boiler/Furnace; 344-Water Heater
- 4
Final Plumbing
232-Plumbing final inspection
Applies to: Accessory Dwelling Unit (ADU) Permit
- 1
Foundation
Per Mesa County Residential Inspection Request Guidelines: 100-Footer or 104-Slab, 120-Setbacks, 475-UFER
- 2
Rough-In
Framing (105/106), electrical (462), plumbing (222), mechanical duct (348) as applicable, before insulation/cover
- 3
Final
116-Building, 232-Plumbing, 356-Mechanical, 476-Electrical final inspections; zoning sign-off required before Certificate of Occupancy
Applies to: Mechanical / HVAC Permit
- 1
Rough-In Mechanical
348-Mech Duct rough-in inspection, typically bundled with framing (106), plumbing (222), and venting (346) inspections
- 2
Gas Appliance
340-Gas Piping & Test; 342-Boiler/Furnace
- 3
Final Mechanical
356-Mechanical final inspection
Applies to: Residential Addition / Remodel / Alteration Permit
- 1
Foundation/Footer
Required before concrete pour for addition footings, deck posts, or garage foundations (100-Footer, 120-Setbacks)
- 2
Framing
106-Framing rough-in inspection; structural connections to the existing structure
- 3
Final
116-Building final inspection; zoning sign-off required where applicable before Certificate of Occupancy
Applies to: Electrical Permit
- 1
Rough-In Electrical
462-Electrical inspection required before insulation is installed, per Mesa County Residential Inspection Request Guidelines
- 2
Final Electrical
476-Electrical final inspection
Applies to: EV Charger / Electric Vehicle Charging Station Permit
- 1
Rough Electrical
462-Electrical rough-in inspection covering conduit runs, wire sizing, and disconnect placement before energizing
- 2
Final
476-Electrical final inspection; new circuit, breaker sizing, and disconnect verified before the charger is energized
Applies to: Fence and Retaining Wall Permit
- 1
Footing
Required for engineered retaining walls 4 ft+ before backfill; specific inspection-code detail for fences/walls was not separately published on Mesa County's Residential Inspection Request Guidelines and should be confirmed with the Building Department
- 2
Final
Completed fence/wall verified against approved plans
Applies to: Re-Roofing Permit
- 1
Mid-Roof
Inspection code 111 — Mid-roof inspection required when 10% to 40% of the roof is complete, covering drip edge, valley flashings, attachment methods, and underlayment
- 2
Final
Required upon completion of all work; a final building inspection is required prior to solar panel installation or reinstallation on the roof
Applies to: Solar Photovoltaic (PV) Permit
- 1
Rough Electrical
462-Electrical rough-in inspection covering conduit runs, wire sizing, and disconnect placement before energizing
- 2
Final
476-Electrical final inspection; a final building inspection (116-Building) is required prior to any solar installation/reinstallation on a reroofed structure
Final inspection only: Demolition Permit
Re-inspection fees
Sources & verification
Verified against official sources. Last reviewed 2026-07-03.
Fees, timelines, and adopted codes are researched from each jurisdiction's published records — see how we verify. Requirements change and vary by project, so always confirm the current details with the Grand Junction building department before you submit. PermitBase is an independent reference and is not affiliated with any government agency.
Grand Junction building permits