This is PermitBase’s published record for Heyburn as of 2026-07-04. It has since been superseded — see the current record. A historical record reflects what PermitBase had verified at that time; it may not capture a real-world change the jurisdiction had made but PermitBase had not yet verified, and it includes any errors we later corrected. Snapshots are never edited retroactively.

Heyburn building permits

Verified

Heyburn, Idaho — as published 2026-07-04.

Verified 2026-07-04 · Source

Codes adopted

2018 International Residential Code (IRC), with Idaho amendments — per Heyburn's own Residential Home Permit Application Plan Submittal Requirements: 'Plans to be designed to the 2018 IRC Code & 2018 IECC. (with Idaho amendments)' (heyburn.id.gov, 2023 Residential New Home Permit application, page 2).2018 International Energy Conservation Code (IECC), with Idaho amendments — same source as above.2018 International Building Code (IBC), with amendments — Heyburn City Code Title 2, Chapter 1, Section 2-1-1(A) adopts by reference 'the following recognized codes as currently adopted by the State of Idaho,' and the State of Idaho's own currently-published adopted-codes list (Idaho DOPL, 'Idaho Adopted Codes,' dopl.idaho.gov/wp-content/uploads/2025/06/2025-Updated-Idaho-Adopted-Codes.pdf) lists the 2018 IBC with amendments as the current state building code.2018 International Existing Building Code (IEBC) — per the same Idaho DOPL 'Idaho Adopted Codes' publication, incorporated into Heyburn's code by the automatic state-code-reference mechanism in Heyburn City Code 2-1-1(A).2018 International Mechanical Code (IMC) and 2018 International Fuel Gas Code (IFGC) — per the same Idaho DOPL 'Idaho Adopted Codes' publication.2017 Idaho State Plumbing Code (based on the 2015 Uniform Plumbing Code) — per the same Idaho DOPL 'Idaho Adopted Codes' publication.2023 National Electrical Code (NEC), with amendments — per the same Idaho DOPL 'Idaho Adopted Codes' publication.IMPORTANT — code-adoption mechanism: Heyburn City Code 2-1-1(A) (amd. Ord. 2026-721, 3-25-2026; Ord. 2026-722, 4-22-2026; codelibrary.amlegal.com/codes/heyburnid/latest/heyburn_id/0-0-0-15510) states verbatim: 'The following recognized codes as currently adopted by the State of Idaho are adopted as the official building codes of the City of Heyburn. Each code shall be deemed superseded by successive versions of such codes as they are adopted or approved by the State of Idaho effective on the 1st day of January the year following the date any such codes are made effective for the State of Idaho, unless a different date is required by state statute.' This means Heyburn's adopted editions track the State of Idaho's current adopted editions automatically, rather than being independently re-adopted by city ordinance edition-by-edition. The city's own 2023-dated Residential and Commercial permit application PDFs both independently confirm the 2018 IRC/2018 IECC editions currently in force, consistent with the state list.NOTE: No Heyburn-specific local amendment TEXT to the IRC/IBC (e.g., a snow-load or seismic design value table, or textual deviations from the model code sections) was found published separately from the state-level amendments referenced above, as of 2026-07-04. Omitted rather than invented.

Permit types & fees

Residential Home Permit (New Construction — Single Family, Duplex, Zero Lot Line, Townhouse)

Verified

Required for new single-family dwellings, duplexes, zero-lot-line homes, and townhouses (separate site-only permit required for townhouses) in the City of Heyburn. Governed by the 2018 IRC and 2018 IECC (with Idaho amendments) per the city's own Residential Home Permit Application. Manufactured and modular homes use a separate application.

Verified 2026-07-04 · Source

Requirements

  • Permit application filled out and signed in its entirety — incomplete applications are not accepted
  • Residential New Home Checklist attached and completed by the plan designer
  • Manual J calculations required for all new construction (including outside air in calculations)
  • Energy compliance documentation: prescriptive approach written on plans, or ResCheck performance method
  • Construction plans designed per the designer's checklist (site plan, foundation/floor framing plan, floor plan/roof framing plan, energy conservation compliance)
  • Engineering and calculations required for walls over 10 feet tall or non-prescriptive wall bracing
  • Digital PDF plans (minimum 11"x17", maximum 24"x36"), readable for all displayed info/data; paper plans accepted but returned as a scanned PDF redset
  • Curb, gutter, and sidewalk with new construction (deferral possible via notarized form + Warranty Deed if none exists adjacent)
  • Fire department access road 20 feet wide, reaching within 150 feet of all exterior walls; turnaround required if access road exceeds 150 feet
  • Separate permits required for electrical, plumbing, and mechanical installations

Required documents

  • RequiredResidential Home Permit ApplicationCity of Heyburn's own application form, revised by the Building Department 6/22/23, per heyburn.id.gov (2023 Residential New Home Permit PDF).
  • RequiredResidential New Home ChecklistDesigner-completed checklist covering site plan, foundation/floor framing plan, floor plan/roof framing plan, and energy conservation items; submitted with plans to the applicant, per the same PDF.
  • RequiredManual J CalculationsRequired for all new construction, including outside air in calculations.
  • RequiredEnergy Compliance Documentation (ResCheck or prescriptive)ResCheck current version, or a prescriptive-method site plan showing all R-values and types.
  • OptionalEngineering & Calculations for Tall Walls/Non-Prescriptive BracingRequired only when walls exceed 10 feet or bracing is non-prescriptive; must be stamped by an Idaho licensed engineer or architect.

Fee schedule

Fee typeAmountNotes

New or Addition Commercial Building Permit (Commercial/Non-Residential/Multi-Family)

Verified

Required for new complete buildings, additions, multi-family (3+ dwelling units), and shell buildings (with or without interior walls) in the City of Heyburn. A pre-submittal meeting is required on all new and addition commercial projects. Governed by the state-referenced 2018 IBC per Heyburn City Code 2-1-1(A).

Verified 2026-07-04 · Source

Requirements

  • Pre-submittal meeting required on all new and addition commercial projects (call to schedule)
  • Civil Site Plan (required separate from architectural site plan): legal description, property lines/setbacks, right-of-way details, fire department access (20 ft wide, 75,000-lb load capacity, within 150 ft of exterior walls), fire hydrants within 1000 feet, grading plan, utility services, parking layout, storm drainage design and calculations (stamped by Idaho Registered Civil Engineer or Landscape Architect), geotechnical report, water/sewer tap sizes, flood plain indication
  • Architectural Site Plan (required in addition to civil site plan): structure locations/distances, IFC-regulated material storage areas, landscaping, exterior lighting, setbacks/easements, trash enclosure/mechanical screening, parking lot design per City Code Title 8 Chapter 9
  • Code/Plan Analysis using the application's example Code Analysis form, separately for each building
  • Com Check Energy Analysis prepared by an Idaho licensed architect or engineer
  • Foundation Plan, Floor Plan, Structural Plans, and Foundation/Structural/Shear Engineering Calculations, all stamped by an Idaho Registered Engineer or Architect (calculations required for all new construction and additions; cannot be a deferred submittal for metal buildings, stair drawings, or permanently fixed furniture)
  • Electrical Plans, Mechanical Plans & Ventilation Calculations, Plumbing Plans (with grease/sand interceptor sizing per Idaho State/Uniform Plumbing Code)
  • Additional Handicap Accessibility Information per current IBC and ANSI A117.1
  • Statement of special inspections per IBC 1704.1.1, with a final report submitted before start of work
  • Completed Wastewater Survey and Sewer Capacity Fee Worksheet
  • Health District letter of approval required prior to permit issuance for any building where food is prepared

Required documents

  • RequiredNew or Addition Commercial Building Permit ApplicationCity of Heyburn's own application form (2023), per heyburn.id.gov.
  • Required(New & Addition) Commercial/Non-Residential/Multi-Family Plan Review ChecklistDetailed civil site plan, architectural site plan, and building-systems checklist within the same application packet; design professional must check off that all requirements are provided on plans.
  • RequiredSewer Capacity Fee WorksheetFixture-count worksheet (lavatories, water closets, etc.) used to calculate sewer capacity fees; included in the application packet.
  • RequiredSample Plans Analysis FormTemplate listing occupancy class, construction type, occupant load, fire ratings, and exiting requirements to be reproduced on the applicant's own plans.

Fee schedule

Fee typeAmountNotes

Sources & verification

Verified against official sources. Last reviewed 2026-07-04.

Fees, timelines, and adopted codes are researched from each jurisdiction's published records — see how we verify. Requirements change and vary by project, so always confirm the current details with the Heyburn building department before you submit. PermitBase is an independent reference and is not affiliated with any government agency.

Later version (2026-07-07) →View current record →All versions →

Permalink: /idaho/minidoka-county/heyburn/as-of/2026-07-04/

Snapshot date: 2026-07-04

Commit: f3cd0f0

Reproducible from PermitBase’s version-controlled dataset, commit f3cd0f0.