How to schedule
Inspections are requested through the building department below.
- Address
- City of Española Planning & Land Use: 409 N. Paseo de Oñate, Española, NM 87532. CID Santa Fe Office: 2550 Cerrillos Road, 3rd Floor, Santa Fe, NM 87505
- Phone
- City of Española Planning & Land Use: (505) 747-6103; CID Santa Fe: (505) 476-4700
- Office hours
- City of Española Planning & Land Use: Monday-Friday, 8:00 AM-5:00 PM, except holidays (appointments available via online scheduling form)
- Website
- Official site
Published scheduling rules
- Española has no city Building Inspectors or building official — all permitting and inspection requests go to CID, not the City. The City's Planning & Land Use Department FAQ directs applicants to 'contact the NM Construction Industries Division to obtain a Building Permit' after zoning approval. (Residential Building Permit (New Construction))
- For CID inspection requests, email CID.Inspection@state.nm.us or call 505-222-9813 / 877-243-0979. For general CID permit questions, contact the CID Santa Fe office at (505) 476-4700. (General)
Inspection sequence
Applies to: Residential Building Permit (New Construction)
- 1
Foundation Inspection
Made after excavations for footings are complete and required reinforcing steel is in place, before concrete placement
- 2
Concrete Slab / Under-Floor Inspection
Made after all in-slab or under-floor building service equipment, conduit, and piping are in place, but before concrete is placed or floor sheathing installed
- 3
Frame Inspection
Made after roof, framing, fire blocking, and bracing are in place and rough electrical, plumbing, and heating are complete and approved
- 4
Weather-Resistive Barrier Inspection
Made after installation of the weather-resistive barrier and before it is covered
- 5
Final Inspection
Made after finish grading and building completion; final electrical, plumbing, and mechanical inspections must be conducted first. CID issues the Certificate of Occupancy after approving the final inspection
Applies to: Plumbing Permit
- 1
Underground / Slab Plumbing
Before concrete pour — verify pipe slope, materials, cleanouts
- 2
Rough-In
After pipes installed, before walls closed
- 3
Final
All fixtures connected, no leaks, proper venting verified
Applies to: Electrical Permit
- 1
Rough-In Inspection
Wiring and conduit installed before walls closed
- 2
Final Inspection
All devices installed, panel labeled, system energized
Applies to: EV Charger / EVSE Permit (NM Construction Industries Division — Electrical Bureau)
- 1
Rough-In Inspection
Charger circuit wiring and breaker sizing before concealment, if applicable
- 2
Final Inspection
EVSE installed, GFCI/disconnect verified, system energized per the 2020 NEC Article 625
Applies to: Fire Sprinkler & Fire Alarm System Permit (NM State Fire Marshal's Office — Fire Code Enforcement Bureau)
- 1
Contractor Pre-Test
Installer conducts a full pre-test of the fire protection system(s) in accordance with applicable NFPA standards; failures must be corrected and re-tested until the system passes before a Final Acceptance Test can be scheduled
- 2
SFMO Final Acceptance Test
A State Fire Inspector is dispatched to witness the Final Acceptance Test after the Final Acceptance Checklist is submitted; approved/stamped plans, manufacturer specifications, testing documentation, and a system representative must be present on-site
Applies to: Mechanical / HVAC Permit
- 1
Rough-In / Equipment
Ductwork and mechanical equipment rough-in before walls closed
- 2
Final
Equipment operational, combustion air verified, venting correct
Applies to: Residential Addition / Alteration Permit
- 1
Frame Inspection
After framing, fire blocking, and bracing complete; rough electrical, plumbing, and heating approved
- 2
Final Inspection
After completion; final electrical, plumbing, and mechanical inspections conducted first
Applies to: Roofing Permit (Reroof)
- 1
Decking Inspection
Required upon removal of the existing roof, before new roofing material is applied
- 2
Final Inspection
Upon completion of the roofing project or application of the roof coating system
Applies to: Solar Photovoltaic (PV) Permit
- 1
Electrical Rough-In / Structural (if applicable)
Conduit runs, mounting/racking attachment, and structural reinforcement (if required) verified before energizing
- 2
Final Electrical Inspection
All electrical connections, grounding, and interconnection point verified per the approved one-line diagram
Final inspection only: Certificate of Occupancy / Change of Use, Demolition Permit
Re-inspection fees
Sources & verification
Verified against official sources. Last reviewed 2026-07-03.
Fees, timelines, and adopted codes are researched from each jurisdiction's published records — see how we verify. Requirements change and vary by project, so always confirm the current details with the Española building department before you submit. PermitBase is an independent reference and is not affiliated with any government agency.
Española building permits