Montrose building inspections
VerifiedInspection sequence, scheduling, and re-inspection fees for building permits in Montrose, Colorado.
Verified 2026-07-06 · Source
How to schedule
Inspections are requested through the building department below.
- Address
- City Hall, 400 E Main Street, P.O. Box 790, Montrose, CO 81402
- Phone
- 970-252-4707
- Office hours
- Monday - Thursday, 8 a.m. - 6 p.m. (City Hall hours, per Building Services page). Inspection scheduling: 970-240-1445, inspection hours 9:00-11:00 a.m. and 1:30-3:30 p.m., with 24-hour advance notice required per the City's Residential/Accessory/Commercial Construction packets.
- Website
- Official site
Inspection sequence
Applies to: Residential Addition / Remodel / Accessory Structure Permit
- 1
Foundation / Setback
Foundation inspection on work not requiring an engineered foundation; setback inspection on engineered foundations
- 2
Rough Plumbing
Prior to covering, with water or air pressure test; E-1 pumps inspected by the City Water Department (240-1484)
- 3
Gas Inspection
After piping/vents/ducts installed and air-tested to 20 psi for 2+ hours
- 4
Framing
After dried-in, before interior walls/ceilings/partitions are covered
- 5
Electrical (State)
Performed by the State Electrical Inspector, not the City, prior to insulation and prior to building final
- 6
Insulation
Prior to wallboard installation
- 7
Wallboard
Whenever material is hung, prior to taping/finishing
- 8
Final Inspection
After building is finished, prior to occupancy; address posted, final electrical inspection form on site required for Certificate of Occupancy
Applies to: Residential Building Permit (New Construction)
- 1
Foundation / Setback
Foundation inspection on work not requiring an engineered foundation; setback inspection on all engineered foundations (engineer must inspect and provide a letter of approval on file before framing inspection)
- 2
Rough Plumbing
Made prior to covering, with water or air pressure test; rough-in inspected prior to covering trench
- 3
Gas Inspection
After all piping, vents, ducts, and appurtenances are installed and air-tested to 20 psi for not less than two hours, tested through the gas meter yoke
- 4
Framing
After the house is dried in, before house wrap and before interior walls/ceilings/partitions are covered; electrical, plumbing, gas, and mechanical ductwork must be installed first; foundation letter must be on file
- 5
Electrical (State)
Performed by the State Electrical Inspector (DORA), not the City, prior to insulation inspection
- 6
Insulation
Prior to wallboard installation; insulation must be exposed for inspection
- 7
Wallboard
Whenever material is hung, prior to taping/finishing joints and fasteners
- 8
Final Inspection
After building is finished, prior to occupancy; address must be posted and a final electrical inspection form from the State Electrical Inspector must be on site before a Certificate of Occupancy is issued
Applies to: Solar PV Permit
- 1
Rough Framing (Solar Mounting)
Mounting/racking rough-in inspected by the City
- 2
Rough Electrical (State of Colorado)
Performed by the State, not the City
- 3
Final Electrical (State of Colorado)
Performed by the State, not the City
- 4
Final Building
City final inspection of the mounting/roof-penetration scope
Applies to: Plumbing / Gas Permit
- 1
Rough Plumbing
Prior to covering, water or air pressure test required; rough-in inspected prior to covering trench
- 2
Gas Inspection
After all piping, vents, ducts, and appurtenances are installed and air-tested to 20 psi for not less than two hours, tested through the gas meter yoke
- 3
Final Inspection
Fixtures connected, venting verified, as part of the overall building-permit final inspection
Applies to: Roofing Permit (Reroofing)
- 1
Shingle Inspection (pre-permit)
Required prior to permit issuance when covering an existing roofing layer
- 2
Mid-Roof Inspection
Required when more than 10% but less than 25% of the roof is complete
- 3
Final Roof Inspection
When the roof is complete; safe roof access must be provided, photographs are not accepted in lieu of inspection
Applies to: Mechanical / HVAC Permit
- 1
Rough Mechanical
Ductwork installed prior to framing inspection, before concealment
- 2
Final Inspection
Equipment operational, verified as part of the overall building-permit final inspection
Final inspection only: Demolition Permit, Fence Permit
Sources & verification
Verified against official sources. Last reviewed 2026-07-06.
Fees, timelines, and adopted codes are researched from each jurisdiction's published records — see how we verify. Requirements change and vary by project, so always confirm the current details with the Montrose building department before you submit. PermitBase is an independent reference and is not affiliated with any government agency.