Skip to main content
PermitBase

Anaconda-Deer Lodge building inspections

Verified

Inspection sequence, scheduling, and re-inspection fees for building permits in Anaconda-Deer Lodge, Montana.

Verified 2026-07-02 · Source

How to schedule

Inspections are requested through the building department below.

Address
ADLC Courthouse, First Floor, 800 Main Street, Anaconda, MT 59711 (local Building permits); Building Codes Bureau, PO Box 200517, Helena, MT 59620-0517 (state electrical/plumbing/mechanical permits)
Phone
(406) 563-4010 (Planning Dept, local Building permits) / (406) 563-4011 (Greg Bahr, Building Inspector) / (406) 841-2056 (State Building Codes Bureau — electrical, plumbing, mechanical)
Office hours
Not published on the ADLC Planning Department page; contact (406) 563-4010

Published scheduling rules

  • A plumbing inspection must be requested and conducted before any plumbing work is covered (Plumbing Permit)

Inspection sequence

Applies to: Mechanical / HVAC Permit

  1. 1

    Gas Piping Pressure Test

    Required before concealing gas piping; 48 hours' notice required

  2. 2

    Rough-In

    Ductwork and mechanical equipment rough-in before walls closed

  3. 3

    Final

    Equipment operational, combustion air and venting verified

Applies to: Residential Building Permit (New Construction)

  1. 1

    Foundation / Concrete

    24-hour advance notice required for all inspections, including concrete pours, per the ADLC Building Permit Application

  2. 2

    Framing

    Per the inspection check sheet issued with the permit

  3. 3

    Final

    Final inspection per the inspection check sheet issued with the permit

Applies to: Change of Use / Occupancy Permit

  1. 1

    Building Inspector Compliance Check

    ADLC Building Inspector (Greg Bahr) confirms compliance as part of the Business License sign-off; required before a license (and therefore occupancy) is granted

  2. 2

    Code Enforcement / Sanitarian Compliance Check

    ADLC Code Enforcement Officer (Vern Tuss) and, where applicable (food service, septic, water), the Tri-County Sanitarian's Office sign off on compliance as part of the same Business License Application

Applies to: Electrical Permit

  1. 1

    Rough-In

    Must be requested with 48 hours' notice before covering up work

  2. 2

    Final

    All devices installed, panel labeled, system energized; requires 48 hours' notice

Applies to: EV Charger / EVSE Permit

  1. 1

    Rough-In

    Must be requested with 48 hours' notice before covering up work

  2. 2

    Final

    Charger installed, circuit verified, unit energized; requires 48 hours' notice

Applies to: Plumbing Permit

  1. 1

    Rough-In

    Must be requested and conducted before covering any portion of plumbing work

  2. 2

    Final

    All fixtures connected, no leaks, proper venting verified

Applies to: Residential Addition / Remodel Permit

  1. 1

    Framing / Structural

    Per the inspection check sheet issued with the permit; 24-hour advance notice required

  2. 2

    Final

    Final inspection per the inspection check sheet issued with the permit

Applies to: Solar PV / Alternative Energy Permit

  1. 1

    Rough Electrical

    Conduit runs, wire sizing, disconnect placement before energizing; 48 hours' notice required

  2. 2

    Final

    Panel connections, interconnection point, and system operation verified

Sources & verification

Verified against official sources. Last reviewed 2026-07-02.

Fees, timelines, and adopted codes are researched from each jurisdiction's published records — see how we verify. Requirements change and vary by project, so always confirm the current details with the Anaconda-Deer Lodge building department before you submit. PermitBase is an independent reference and is not affiliated with any government agency.

Anaconda-Deer Lodge building permits

Get alerts for Anaconda-Deer Lodge

We'll email you when Anaconda-Deer Lodge's fees, documents, or codes change — not often.

We only use your email to send permit updates. No spam, unsubscribe anytime. Privacy.