Fountain Hills building inspections
VerifiedInspection sequence, scheduling, and re-inspection fees for building permits in Fountain Hills, Arizona.
Verified 2026-07-06 · Source
How to schedule
Inspections are requested through the building department below.
- Address
- Town Hall, 16705 E. Avenue of the Fountains, Fountain Hills, AZ 85268
- Phone
- 480-816-5123
- Office hours
- Building Safety office hours for plan review, phone calls, front counter assistance and building code questions: Monday - Thursday, 7 a.m. - 6 p.m. Inspections are conducted 7 a.m. - 4 p.m. Monday through Friday. The Town of Fountain Hills only accepts permit applications online through T.O.P.P.S. (Town's Online Permitting and Planning System), a Citizenserve-hosted portal; there is no walk-in/paper submittal option. Source: Town of Fountain Hills Building Safety page (fountainhillsaz.gov/204/Building-Safety) and Building Permit Forms & Checklists page (fountainhillsaz.gov/502/Building-Permit-Forms-Checklists).
- Website
- Official site
Inspection sequence
Applies to: Residential Building Permit (New Construction / Additions)
- 1
Stormwater / Limits Fence
Prior to permit issuance — BMPs, inlets, trackout pad and site limits fence per copy of site plan
- 2
Footing
Prior to placing concrete — copies of compaction tests required
- 3
Foundation
Prior to placing concrete or grout — required hold-downs installed, all steel tied, elevation set
- 4
Under-Slab Plumbing/Heating/Electric
Before fill placement; all piping under test
- 5
Pre-Slab
Before concrete is placed — pipes sleeved, footings formed
- 6
Roof Diaphragm Nailing / Wall Shear Nailing
Prior to dry-in — stamped truss calcs and ladder on site; windows installed, flashed, NFRC-labeled
- 7
Rough Framing / Plumbing / Electrical / Mechanical
Before top-out — gas/DWV/water under test, boxes/panel/service made up, gas appliance venting installed
- 8
Insulation
Before drywall — per approved plans
- 9
Drywall
After all insulation approved, before taping
- 10
Final Grade & Site Improvements / Landscaping
Before building final — site plan on site, landscape plan complete
- 11
Final Building
Gas/electric meters set, appliances operational, blower door test results provided
Applies to: Plumbing Permit (Water Heater / Minor)
- 1
Under-Slab Plumbing
Before fill placement — all piping under test, sticker on cleanout for tie-in
- 2
Rough Plumbing
Gas, DWV and water under test, before walls closed
- 3
Sewer Final
Before building final — sticker in panel
- 4
Final Building
Fixtures connected, water heater and gas connections verified
Applies to: Swimming Pool & Spa Permit
- 1
Limits Fence
Prior to permit issuance — provide copy of site plan showing temporary construction barrier
- 2
Pre-Slab / Plumbing
Pipes sleeved before concrete; pool plumbing under test
- 3
Permanent Power / Electrical
Pool electrical panel, bonding, and GFCI protection verified
- 4
Final Building
Barrier compliance, VGBA anti-entrapment devices, and equipment verified
Applies to: Electrical Permit (Minor / One-Discipline)
- 1
Rough Electrical
Boxes, panel and service made up, before walls are closed
- 2
Permanent Power
When top-out is approved; 2-20 amp GFCI receptacles installed
- 3
Final Building
Gas/electric meters set, appliances operational
Applies to: Residential Remodel Permit
- 1
Rough Framing/Plumbing/Electrical/Mechanical
Structural connections to existing structure, per the Town's 2024 Required Inspections list
- 2
Insulation / Drywall
Before and after drywall per approved plans
- 3
Final Building
Completed work verified against approved plans
Applies to: EV Charger / EVSE Permit
- 1
Rough Electrical
Conduit runs, wire sizing, disconnect placement before cover, per the Town's standard electrical rough-in inspection practice
- 2
Final Electrical
EVSE unit connections, breaker/disconnect, and grounding verified before energizing
Applies to: Fence and Retaining Wall Permit
- 1
Retaining Wall Footings
Prior to placing concrete or grout — reinforcement, forms, and shoring in place
- 2
Final Building
Completed fence/wall verified against approved plans
Applies to: Fire Sprinkler and Fire Alarm System Permit
- 1
Rough Inspection
All system components in place and secured, connected to the permanent water supply, approved 24x36 fire sprinkler plans on-site, and a cold-water test at a minimum of 200 psi for 2 hours showing no visible leakage or pressure reduction (residential/NFPA 13D systems); witnessed by the Fountain Hills Fire Department
- 2
Final Inspection
System flowed to verify activation of the flow switch and alarm bell; hydraulic design placard in place at the riser; spare sprinklers present in the riser compartment
Applies to: Mechanical / HVAC Permit (Minor Replacement)
- 1
Rough Mechanical
All gas appliance venting installed; installation manual and duct leakage report provided if required
- 2
Final Building
Equipment operational, clearances and combustion air verified
Applies to: Solar Photovoltaic & Energy Storage Permit
- 1
Rough Electrical
Conduit runs, wire sizing, disconnect placement before energizing
- 2
Final Building
Panel mounting, racking attachment, roof penetration sealing, electrical connections, interconnection point, and rapid-shutdown labeling verified
Final inspection only: Change of Use / Certificate of Occupancy, Sign Permit
Re-inspection fees
Sources & verification
Verified against official sources. Last reviewed 2026-07-06.
Fees, timelines, and adopted codes are researched from each jurisdiction's published records — see how we verify. Requirements change and vary by project, so always confirm the current details with the Fountain Hills building department before you submit. PermitBase is an independent reference and is not affiliated with any government agency.