Spanish Fork building inspections
VerifiedInspection sequence, scheduling, and re-inspection fees for building permits in Spanish Fork, Utah.
Verified 2026-07-01 · Source
How to schedule
Inspections are requested through the building department below.
- Address
- 40 S Main St, Room 120, Spanish Fork, UT 84660
- Phone
- (801) 804-4540
- Office hours
- Mon–Fri 8:00 AM – 5:00 PM
- Website
- Official site
Published scheduling rules
- Schedule all inspections at least 24 hours in advance via CitizenServe. If work is not ready at the scheduled time, a $93 not-ready fee applies. (Residential Building Permit)
- Schedule inspections at least 24 hours in advance via CitizenServe. A $93 not-ready fee applies if work is not ready when the inspector arrives. (Roofing Permit)
- Schedule inspections at least 24 hours in advance. (Deck Permit)
- Apply and track review status through the CitizenServe portal at citizenserve.com/spanishforkcity; schedule inspections at least 24 hours in advance through the same portal. (Commercial Building Permit)
- Apply and track review status through the CitizenServe portal at citizenserve.com/spanishforkcity; schedule inspections at least 24 hours in advance. (Commercial Tenant Improvement / Tenant Finish Permit)
- Apply for all permits via CitizenServe at citizenserve.com/spanishforkcity. Schedule inspections through the same portal at least 24 hours in advance. (General)
Inspection sequence
Applies to: Residential Building Permit
- 1
Setback & Footings
Placement on property per approved site plan verified; string lines for property lines required; forms and rebar in place; site geotechnical report provided to inspector.
- 2
Foundation
Forms and reinforcing steel in place before concrete pour; UFER ground verified.
- 3
Underground Plumbing / Electrical / Mechanical
All underground or under-slab work before burial or concrete covering. Under-slab plumbing: minimum 5 PSI air test or 5-foot head of water for 15 minutes. Underground power trench: before backfilling, 48-inch minimum depth.
- 4
Exterior Shear Wall
All structural sheathing, foundation straps, and mechanical connectors on exterior before weather barrier installation.
- 5
Flashing & Weather Barrier
After installation of exterior weather barrier, window/door/other flashings, lath, and expansion joints — before siding, masonry, or roofing. All penetrations must be sealed. Cold weather (below 40°F) requires tenting and heating before inspection.
- 6
4-Way (Framing + MEP Rough-In)
Framing, structural members, shear walls, and all roughed-in electrical, mechanical, fuel gas piping, and plumbing before insulation or wall cover. Gas line pressure test (3 PSI minimum) required separately.
- 7
Gas Line Pressure Test
Gas line pressurized to 3 PSI minimum (typically 15 PSI). Scheduled separately from the 4-way inspection.
- 8
Insulation
Insulation, doors, windows, and HVAC verified to meet IECC requirements or submitted REScheck.
- 9
Drywall
After sheetrock installation, before taping or mudding.
- 10
Final
Completed building or structure before use or occupancy. Final inspection checklist available at the office or via CitizenServe.
Applies to: Plumbing Permit
- 1
Underground / Under-Slab Plumbing
Before burial or concrete covering. Minimum 5 PSI air test or 5-foot head of water for 15 minutes.
- 2
Sewer Lateral
Filled with water to not less than 10-foot head; maintained for 15 minutes. Sewer test plug removed with inspector on-site to verify flow.
- 3
Water Lateral
Minimum 1-inch size, 36-inch minimum depth.
- 4
Rough-In (in 4-way for new construction)
Roughed-in plumbing included in 4-way inspection for new construction — before walls closed.
- 5
Shower Pan
Pan filled with water to minimum 2 inches at threshold; 15-minute test duration.
- 6
Final
All fixtures connected, water flowing, no leaks, proper venting verified.
Applies to: Accessory Dwelling Unit (ADU) Permit
- 1
Foundation / Setbacks
Forms and rebar in place; property line setbacks verified before concrete pour.
- 2
4-Way (Framing + MEP Rough-In)
Framing, shear walls, and all roughed-in electrical, mechanical, and plumbing.
- 3
Insulation
Insulation verified per IECC requirements.
- 4
Final
All work complete — certificate of occupancy issued upon passing.
Applies to: Basement Finish Permit
- 1
Framing
Wall framing, fire blocking, and egress window openings. Fire block continuously along foundation top plates; draft stop from top plate to bottom plate behind stud and at 10-foot intervals. Acceptable materials: tightly packed fiberglass insulation, 1/2-inch drywall, 3/4-inch OSB, or solid 2x blocking.
- 2
MEP Rough-In
Electrical, plumbing, and HVAC rough-ins before walls closed.
- 3
Insulation
Insulation on exterior walls, vapor barrier placement, verified against IECC requirements.
- 4
Final
Drywall, fixtures, smoke/CO detectors, and all finishes complete.
Applies to: Mechanical / HVAC Permit
- 1
Gas Line Pressure Test
Gas line pressurized to 3 PSI minimum (typically 15 PSI). Scheduled separately from the 4-way framing inspection.
- 2
Rough-In (in 4-way for new construction)
Roughed-in mechanical and gas piping included in 4-way inspection for new construction.
- 3
Insulation / IECC
HVAC verified to meet IECC requirements per submitted REScheck.
- 4
Final
Equipment operational, combustion air verified, gas pressure tested, thermostat functional.
Applies to: Swimming Pool Permit
- 1
Excavation / Steel
Pool shell excavation, rebar, and plumbing before gunite/shotcrete.
- 2
Electrical / Bonding
Pool bonding grid, equipment connections, GFCI protection per 2023 NEC Article 680.
- 3
Barrier
Pool fence/barrier — 48-inch minimum height, self-closing/self-latching gates per 2021 IRC Chapter 31.
- 4
Final
Pool complete, equipment operational, all barriers in place.
Applies to: Deck Permit
- 1
Setback & Footings
Footing forms and rebar in place before concrete pour. Frost depth is 30 inches per city Design Criteria.
- 2
Framing
Posts, beams, joists, ledger connection, and hardware verified.
- 3
Final
Decking, stairs, guards, and railings complete. IRC requires 36-inch guard height for decks 30+ inches above grade.
Applies to: Electrical Permit
- 1
Power / Service Panel
Inspection of electrical service panel before utility hook-up. Meter base and grounding system must comply with 2023 NEC and city standards.
- 2
Rough-In (in 4-way for new construction)
Roughed-in electrical included in the 4-way framing inspection for new construction — before walls closed.
- 3
Final
All devices installed, GFCI/AFCI protection verified, panel labeled.
Applies to: Solar Panel Permit
- 1
Underground Power Trench (ground-mounted systems)
Before backfilling, minimum 48-inch depth for underground conduit.
- 2
Power / Electrical (Service Panel)
Electrical service panel and meter base before utility hook-up. Grounding system must comply with 2023 NEC and city standards.
- 3
Final
Panel mounting, racking attachment, roof penetration sealing, and electrical connections verified. System operational.
Applies to: Commercial Building Permit
- 1
Rough-In (Structural / Electrical / Mechanical / Plumbing)
Rough-in work verified before walls are closed, per Spanish Fork's Inspections page.
- 2
Final
All work complete before occupancy.
Applies to: Commercial Tenant Improvement / Tenant Finish Permit
- 1
Rough-In (Electrical / Mechanical / Plumbing)
Interior rough-in for the tenant space verified before walls/ceiling are closed.
- 2
Final
All finish work complete before occupancy.
Applies to: Demolition Permit
- 1
Pre-Demolition
Utility disconnects complete and any required asbestos clearance obtained before work begins.
- 2
Final / Site Clear
Site cleared, foundation removed or capped, site conditions verified.
Applies to: EV Charger / EVSE Permit
- 1
Power / Service Panel
Inspection of electrical service panel/circuit before energizing the EVSE. Meter base and grounding system must comply with 2023 NEC and city standards.
- 2
Final
Charger mounted and energized, GFCI/breaker protection verified per NEC Article 625 (Electric Vehicle Power Transfer System).
Applies to: Roofing Permit
- 1
Flashing & Weather Barrier
After installation of weather barrier and flashings, before installation of roofing products. All penetrations must be sealed.
- 2
Final
Completed roof — verify ice and water shield, flashing, drip edge, nailing pattern, and ventilation.
Re-inspection fees
Sources & verification
Verified against official sources. Last reviewed 2026-07-01.
Fees, timelines, and adopted codes are researched from each jurisdiction's published records — see how we verify. Requirements change and vary by project, so always confirm the current details with the Spanish Fork building department before you submit. PermitBase is an independent reference and is not affiliated with any government agency.