Fire Sprinkler and Fire Alarm System Permit — Englewood, Colorado · Requirements sheet
Verified 2026-08-13 · Source: https://www.englewoodco.gov/government/city-departments/police-department/special-operations-and-code-division/fire-prevention/permits
PermitBase is an independent reference and is not affiliated with any government agency. Requirements change and vary by project — confirm current details with the building department before you submit.
Fire Sprinkler and Fire Alarm System Permit in Englewood, Colorado
Required for installation, modification, or repair of any fire sprinkler system (NFPA 13/13D/13R), fire alarm or detection system, fire pump, standpipe, private fire hydrant, smoke control system, or related fire-protection life-safety system in Englewood. Fire code plan review, permitting, and inspection are handled by the City's own Fire Marshal's Office — housed under the Police Department's Special Operations and Code Division at 3615 S. Elati St., Englewood, CO 80110 — not by a fire protection district, even though the City disbanded its uniformed Fire/Rescue Department in 2015 and contracts fire suppression and EMS response to the Denver Fire Department. The Fire Marshal's Office enforces the City's locally amended 2024 International Fire Code (IFC), effective May 6, 2026; plans submitted May 6-31, 2026 may use either the 2021 or the 2024 IFC, and the 2024 IFC is mandatory for all new submittals from June 1, 2026. Operational and construction permits, including sprinkler and alarm permits, are applied for through the same ims.englewoodco.gov portal used for general building permits — but on a separate application and review track, so budget time for both.
Verified 2026-08-13 · Source
When you need this permit
- Governed by the 2024 International Fire Code (IFC) as locally amended by the City of Englewood, effective May 6, 2026 (2021 IFC and 2024 IFC both acceptable for plans submitted May 6-31, 2026; 2024 IFC mandatory for all submittals from June 1, 2026 onward) — per the Fire Marshal's Office's own Codes page and its published 2024 Amendments document
- A construction permit is required to install, modify, or repair a fire sprinkler system, fire alarm/detection system, fire pump, standpipe, private fire hydrant, or smoke control system, among other fire-protection systems, per locally amended IFC § 105.6 as administered by the Fire Marshal's Office
- Separate permits are required for fire detection (alarm) systems and fire sprinkler/clean-agent suppression systems — a single combined application is not accepted for both system types, per the City's 2024 Fire Code Amendments
- Fire protection system shop drawings/plans require, at minimum, a NICET III (or higher) certified preparer or a Professional Engineer's stamp for the specific system being designed, per the City's Commercial Remodel/TI/Change of Occupancy checklist and the 2024 Fire Code Amendments' shop-drawing requirements
- A Conditional Sprinkler Installation Permit may be issued to contractors in good standing (with a compliant permit history) while full plan review is still pending, subject to payment of permit fees; conditional permits do not cover fire pump installation and are the contractor's responsibility to convert to a full permit — per the City's 2024 Fire Code Amendments (Section P103)
- A Conduit-Only Rough-In fire alarm installation permit may similarly be issued before full plan review approval, limited strictly to back boxes, conduit stubs, and raceway installed by a State- and City-licensed electrical contractor in good standing, subject to payment of permit fees — per the same amendments
- Where sprinkler/alarm work accompanies a commercial building project, fire protection system plans are submitted as a deferred submittal alongside (but reviewed on a separate track from) the Building Division's own Commercial Remodel/TI/Change of Occupancy submittal, per that checklist
- Applications are submitted through the 'Fire Application' link on ims.englewoodco.gov, the same portal infrastructure used for other Englewood permits but routed to and reviewed by the Fire Marshal's Office rather than the Building Division
- No public dollar fee schedule for fire construction or operational permits was found published by the City — the 2026 Building Permit Fee Schedule's own 'Fire Plan Review' line item redirects applicants to 'See Fire Marshal's website,' but the Fire Marshal's Office's own Permits, Codes, FAQ/Resources, and Office Directory pages do not publish a fee table as of the last verification; fees appear to be assessed directly through the ims.englewoodco.gov Fire Application at the time of submittal
Required documents
Check off what you have — your progress is saved on this device.
Not ready yet — 0 of 2 required documents checked.
This checker covers one permit. A full project usually triggers several — our checklist will assemble all of them, free →
Fee schedule
The 2026 Building Permit Fee Schedule's 'Fire Plan Review' line item states only 'See Fire Marshal's website'; Show full citationHide
The 2026 Building Permit Fee Schedule's 'Fire Plan Review' line item states only 'See Fire Marshal's website'; the Fire Marshal's Office's own Permits, Codes, FAQ/Resources, and Office Directory pages, plus a direct site-wide search of englewoodco.gov, turned up no published fee table as of the last verification. Confirm current fees directly with the Fire Marshal's Office (303-762-2475) or at time of application via the ims.englewoodco.gov Fire Application.The City's own Building Permit Application form instructs applicants to 'Include all trades except Fire' in the general Building Permit valuation figure — confirming fire-protection-system cost is… Show full citationHide
The City's own Building Permit Application form instructs applicants to 'Include all trades except Fire' in the general Building Permit valuation figure — confirming fire-protection-system cost is excluded from, and billed separately from, the general Building Division valuation-based fee table.Review timeline
Inspection process
- 1
Rough-In Inspection
Underground piping, wiring, and device rough-in inspected before concealment, where applicable to the system type, scheduled through the ims.englewoodco.gov Fire Application.
- 2
Acceptance/Final Test
System tested per the applicable NFPA standard (13/13D/13R for sprinklers, 72 for alarms) before being placed in service; approved plans and permit must be available for the Fire Marshal's Office inspector.
See the full Englewood inspection guide — scheduling & re-inspection fees →
Tips
- Englewood disbanded its own uniformed Fire/Rescue Department in 2015 and contracts fire suppression and EMS response to the Denver Fire Department, but retained its own City Fire Marshal's Office (under the Police Department's Special Operations and Code Division) for fire code enforcement, plan review, and permitting — do not assume Denver Fire, or an independent special district like West Metro or South Metro Fire Rescue, is the reviewing authority for a fire sprinkler/alarm permit in Englewood; it is the City's own office.
- The Fire Marshal's Office adopted the 2024 IFC effective May 6, 2026, ahead of the general Building Division code-cycle rollout referenced elsewhere in this record — confirm which IFC edition governs a project whose plans straddle the May 6-31, 2026 grace window.
- No public fire permit fee table was found anywhere on the City's site despite direct checks of the Building Permit Fee Schedule, the Fire Marshal's Office's own pages, and its 2024 Fire Code Amendments document — budget extra lead time to get a fee quote directly from the Fire Marshal's Office (303-762-2475) rather than expecting to estimate it from a published table the way general building fees can be.
- Conditional/interim permits (Conditional Sprinkler Installation Permit, Conduit-Only Rough-In Permit) let good-standing contractors begin limited work before full plan approval — useful for schedule-sensitive tenant improvement projects — but both still require payment of permit fees and the conditional sprinkler permit specifically excludes fire pump installation.
- Separate permits are required for fire detection (alarm) and fire sprinkler/suppression systems — do not assume one combined 'fire system permit' covers both scopes.
Frequently asked questions
Sources & verification
Verified against official sources. Last reviewed 2026-08-13.
Fee schedules
Applications & forms
Codes & ordinances
Department & other records
Fees, timelines, and adopted codes are researched from each jurisdiction's published records — see how we verify. Requirements change and vary by project, so always confirm the current details with the Englewood building department before you submit. PermitBase is an independent reference and is not affiliated with any government agency.
Englewood's permit history isn't searchable here yet
This page covers what the permit requires. What we don't have for Englewood yet is the record of permits actually issued — the history you'd search by street address. That is a gap in our coverage, not a statement about any particular property.
Your email, and the place — never an address. We only use it to tell you when Englewood lands. Privacy.
Other permits in Englewood
Fire Sprinkler and Fire Alarm System Permit in other cities
Compare fire sprinkler and fire alarm system permit fees across Colorado →
Look up this fee in a different city →