Skip to main content
PermitBase

Colorado Springs building inspections

Verified

Inspection sequence, scheduling, and re-inspection fees for building permits in Colorado Springs, Colorado.

Verified 2026-07-17 · Source

How to schedule

Inspections are requested through the building department below.

Address
2880 International Circle, Colorado Springs, CO 80910 (Main Office); North Office: 3939 Cordera Crest Avenue, Colorado Springs, CO 80924
Phone
(719) 327-2880
Office hours
Permits & Contractor Licensing: 7:30 a.m.–4:15 p.m.; Plan Review, Floodplain, and Enumeration: by appointment only; Inspectors office hours: 7:30–8:30 a.m.

Inspection sequence

Applies to: Residential Building Permit (New Construction)

  1. 1

    Foundation / Footings

    Before concrete pour — footings must extend at least 30 inches below undisturbed ground surface (frost depth)

  2. 2

    Framing

    After framing complete, before insulation or wall cover

  3. 3

    MEP Rough-In

    Mechanical, electrical, and plumbing rough-in before walls closed

  4. 4

    Insulation / Energy

    Insulation and 2021 IECC (with Colorado Model Electric/Solar Ready Code) compliance before drywall

  5. 5

    Final

    All work complete, ready for Certificate of Occupancy

Applies to: Accessory Dwelling Unit (ADU) Permit

  1. 1

    Foundation

    Footings and foundation before concrete pour — 30-inch minimum frost depth

  2. 2

    Framing

    Structural framing, egress windows, fire separation (if attached)

  3. 3

    MEP Rough-In

    Mechanical, electrical, plumbing rough-ins before walls closed

  4. 4

    Final

    All work complete, ready for Certificate of Occupancy

Applies to: Residential Addition / Remodel Permit

  1. 1

    Foundation (if new footings)

    Before concrete pour — 30-inch minimum frost depth

  2. 2

    Framing

    After framing complete, before insulation or wall cover

  3. 3

    MEP Rough-In

    Electrical, plumbing, mechanical rough-in before walls closed

  4. 4

    Final

    All work complete per approved plans

Applies to: Commercial Tenant Improvement Permit

  1. 1

    Framing / Structural

    After framing complete, before walls covered

  2. 2

    MEP Rough-In

    Mechanical, electrical, plumbing rough-in before walls closed

  3. 3

    Final / Certificate of Occupancy

    All work complete, life safety systems functional

Applies to: Deck / Covered Patio Permit

  1. 1

    Footing

    Before concrete pour for structural post footings — 30-inch minimum frost depth

  2. 2

    Framing

    Structural framing before decking/cover installed

  3. 3

    Final

    Structure complete per approved plans; composite material evaluation report on-site if applicable

Applies to: Plumbing Permit

  1. 1

    Underground / Under-slab

    Before concrete pour — pipe slope, materials, cleanouts

  2. 2

    Rough-In

    After pipes installed, before walls closed

  3. 3

    Final

    All fixtures connected, no leaks, proper venting verified

Applies to: Demolition Permit (Wrecking Permit)

  1. 1

    Pre-Demolition Utility & Asbestos Verification

    Verification of gas/electric disconnection and CDPHE asbestos clearance before demolition begins

  2. 2

    Final

    Site cleared, debris removed

Applies to: Electric Vehicle (EV) Charger / EVSE Permit

  1. 1

    Rough Electrical

    Conduit runs, wire sizing, disconnect placement before cover

  2. 2

    Final

    EVSE circuit and connection verified, panel labeled, system energized

Applies to: Electrical Permit

  1. 1

    Rough-In

    Wiring and conduit installed before walls closed

  2. 2

    Final

    All devices installed, panel labeled, system energized

Applies to: Mechanical / HVAC Permit

  1. 1

    Rough-In / Equipment

    Equipment installation and ductwork before walls closed

  2. 2

    Final

    Equipment operational, combustion air and venting verified

Applies to: Roofing Permit (Reroof)

  1. 1

    Mid-Roof (Tile only)

    Roof dry-in inspection required for tile roofs (BTR) — after underlayment, batten strips, and support flashing are in place, before tile is stocked or installed. NOT required for typical asphalt or Direct-to-Deck metal shingle roofs.

  2. 2

    Final

    Completed roof — verify flashing, drip edge, underlayment, and Class A/B covering compliance

Applies to: Solar PV Permit

  1. 1

    Rough Electrical

    Conduit runs, wire sizing, disconnect placement before cover

  2. 2

    Final — Structural / Racking and Electrical

    Panel mounting, racking attachment, roof penetration sealing, and all electrical connections verified

Colorado Springs building permits

Get alerts for Colorado Springs

We'll email you when Colorado Springs's fees, documents, or codes change — not often.

We only use your email to send permit updates. No spam, unsubscribe anytime. Privacy.