Skip to main content
PermitBase

Plumbing Permit in Estes Park, Colorado

Required for plumbing installation, alteration, or repair in Estes Park. Issued by the Town's Division of Building Safety (via SAFEbuilt Colorado) under the 2021 International Plumbing Code as adopted by reference at Municipal Code Section 14.12.060 (amending IBC 101.4.3); on-site wastewater (septic) systems instead fall under the Town's On-Site Wastewater Treatment System Regulations enforced by Larimer County Department of Health and Environment.

Verified 2026-07-06 · Source

When you need this permit

  • Submit via Community Connect Public Portal, referencing the associated building permit number if applicable
  • Septic Permits (on-site wastewater treatment) must be obtained from the Larimer County Department of Health and Environment BEFORE applying for a related Town Building Permit
  • Medical gas system work is governed by the same International Plumbing Code adoption
  • Contractor must be appropriately Colorado-licensed; contemporaneous license review may apply per the Town's Contemporaneous Review Requirements document

Required documents

Check off what you have — your progress is saved on this device.

Not ready yet0 of 1 required documents checked.

This checker covers one permit. A full project usually triggers several — our paid checklist will assemble all of them, from $29

Fee schedule

Plumbing Permit Fee (same valuation-based Table 1-A as building permits)Ordinance No. 03-16, effective May 1, 2016
$23.50 minimum, scaling per valuation tiers
Plan Review Fee
50% of the permit fee
Re-inspection FeeTable 1-B, Ordinance No. 03-16
$100.00/hour, minimum charge one hour

Review timeline

Plan review
Not published — contact the department

How long did your Plumbing Permit permit actually take in Estes Park?

Anonymous — one question, no email. Answers are combined and only shown once at least 5 people have reported.

Inspection process

  1. 1

    Underground/Rough Plumbing Inspection

    Underground and rough-in plumbing installed before concealment

  2. 2

    Final Plumbing Inspection

    Fixtures connected, tested per Municipal Code Section 110.7 (testing requirements added by local amendment), no leaks, proper venting verified

See the full Estes Park inspection guide — scheduling & re-inspection fees →

Tips

  • If your project involves a septic system, get the Larimer County Health Department Septic Permit FIRST — the Town's own guidance states this must happen before the Town Building Permit application.
  • Schedule inspections by 4:00pm the day before through Community Connect; no same-day inspections are available.

Frequently asked questions

Estes Park requires a plumbing permit for: Submit via Community Connect Public Portal, referencing the associated building permit number if applicable; Septic Permits (on-site wastewater treatment) must be obtained from the Larimer County Department of Health and Environment BEFORE applying for a related Town Building Permit; Medical gas system work is governed by the same International Plumbing Code adoption; Contractor must be appropriately Colorado-licensed; contemporaneous license review may apply per the Town's Contemporaneous Review Requirements document. If your project isn't listed, confirm with Town of Estes Park Community Development Department — Division of Building Safety (administered by SAFEbuilt Colorado) at (970) 577-3735 before starting work.

In Estes Park, the published Plumbing Permit Fee (same valuation-based Table 1-A as building permits) is: $23.50 minimum, scaling per valuation tiers. Additional published fees: Plan Review Fee — 50% of the permit fee; Re-inspection Fee — $100.00/hour, minimum charge one hour. These are the jurisdiction's own published figures — see the fee schedule table and source citations on this page.

Estes Park does not publish a plan-review timeline for this permit. Contact Town of Estes Park Community Development Department — Division of Building Safety (administered by SAFEbuilt Colorado) at (970) 577-3735 for current turnaround.

You'll need: Plumbing Permit Application (Community Connect Portal). Depending on your project, Estes Park may also ask for: Larimer County Septic Permit (if on-site wastewater treatment is involved). See the required-documents checklist on this page for details on each.

Estes Park requires 2 inspection(s) for a plumbing permit, in order: Underground/Rough Plumbing Inspection, Final Plumbing Inspection. Schedule each through Town of Estes Park Community Development Department — Division of Building Safety (administered by SAFEbuilt Colorado) ((970) 577-3735).

Apply through Town of Estes Park Community Development Department — Division of Building Safety (administered by SAFEbuilt Colorado) at 170 MacGregor Avenue, Room 230, PO Box 1200, Estes Park, CO 80517. Phone: (970) 577-3735, email: building@estes.org. Office hours: Monday-Friday 8:00am-4:00pm, second floor of Town Hall. Official information: https://estespark.colorado.gov/building-safety.

Estes Park, Colorado has adopted: 2021 International Building Code (IBC), effective January 1, 2024, adopted by reference with local amendments — Estes Park Municipal Code Section 14.12.010 (originally adopted as Exhibit A to Ordinance 04-23); includes all secondary codes listed in IBC Section 101.4 EXCEPT that subsection 101.4.5 (fire code) is stricken, because fire code is adopted separately by the Estes Valley Fire Protection District; 2021 International Residential Code (IRC), effective January 1, 2024, adopted by reference with local amendments at Municipal Code Sections 14.12.070 and 14.12.080 (originally Exhibits B and C to Ordinance 04-23); 2021 International Swimming Pool and Spa Code, adopted by reference with amendments at Section 14.12.060 (Ordinance 04-23); International Property Maintenance Code — adopted only as to Chapters 1 and 2; all other chapters stricken by local amendment (Municipal Code Section 14.12.030); 2021 International Energy Conservation Code (IECC), amended to incorporate the Colorado Model Electric Ready and Solar Ready Code (Municipal Code Section 14.12.040, Exhibit D to Ordinance 04-23); 2021 International Plumbing Code — applies to installation/alteration/repair/replacement of plumbing systems including medical gas systems (Municipal Code Section 14.12.060, amending IBC 101.4.3); on-site wastewater treatment (septic) systems instead governed by the Town's On-Site Wastewater Treatment System Regulations, enforced by the Larimer County Department of Health and Environment; Local structural design criteria (Municipal Code Section 14.12.060, amending IBC Chapter 16): ground snow load table by elevation — 35 psf up to 5,000 ft, 45 psf to 6,000 ft, 50 psf to 6,500 ft, 60 psf to 7,000 ft, 70 psf to 8,000 ft, 100 psf to 9,000 ft, 140 psf to 10,000 ft (linear interpolation permitted between tabulated values; above 10,000 ft governed by the Colorado Design Snow Loads Report and Map, SEAoC, dated May 6, 2015); final design roof snow load never less than 30 psf uniformly distributed (greenhouses may take full ASCE 7 load reductions); basic design wind speed per the Colorado Front Range Gust Map (SEAoC, dated November 18, 2013) or the Larimer County Basic Design Wind Speed Map, Exposure Category C unless a design professional justifies otherwise; Frost protection (Municipal Code Section 14.12.060, amending IBC 1809.5): foundations must extend a minimum of 30 inches below grade, be designed per ASCE 32, or be erected on solid rock; shallow foundations may not bear on frozen soil; a narrow exception exists for small (600 sq ft light-frame / 400 sq ft other) Risk Category I free-standing buildings with 10-foot or lower eave height; Roof covering / wildfire hardening (Municipal Code Section 14.12.060, amending IBC 1505.1): roofs generally required to be Class A (tested per ASTM E108 or UL 790); a Class B/C exception exists only for limited additions to certain existing R-3/U buildings meeting setback distances, but ANY roof covering located in the Town's mapped Wildfire Hazard Area must be minimum Class B (Class C permitted outside that area for the limited exception scenario); rooftop PV systems must be listed/tested per UL 2703; an ice barrier (two layers of cemented underlayment, or a self-adhering polymer-modified bitumen sheet) is required at eaves, extending at least 24 inches inside the exterior wall line, except on unconditioned detached accessory structures; Radon-resistant construction (Municipal Code Section 14.12.060, adding IBC 1811): required for new I-1, I-2 nursing home, R-2, R-3, and R-4 occupancies per IRC Appendix AF as locally amended; Fireplace restrictions (Municipal Code Section 14.12.060, adding IBC 2111.15): fireplaces within the mapped 'Restricted Area' (Larimer County Fireplace Area Map) must be gas or gas-log, or otherwise meet the Town's factory-built-fireplace/EPA-certified-appliance criteria — verify against the current map and Building Division before assuming an open-hearth wood fireplace is permissible; 2017 local amendments to the International Residential Code specific to Vacation Homes (short-term rentals), IRC Section R327, effective July 1, 2017 — codified at Estes Park Municipal Code Section 14.12.080; Full local amendment text hosted at Estes Park Municipal Code Title 14 (Buildings and Construction), Chapter 14.12 — library.municode.com/co/estes_park. Local amendments apply — see the Estes Park overview page for the full list.

Septic (on-site wastewater treatment) permits are issued by the Larimer County Department of Health and Environment (970-577-2050), not the Town of Estes Park, and must be obtained before applying for a related Town Building Permit.

Sources & verification

Verified against official sources. Last reviewed 2026-07-06.

Fees, timelines, and adopted codes are researched from each jurisdiction's published records — see how we verify. Requirements change and vary by project, so always confirm the current details with the Estes Park building department before you submit. PermitBase is an independent reference and is not affiliated with any government agency.