How to schedule
Inspections are requested through the building department below.
- Address
- City of Bloomfield Planning and Zoning: 915 N. 1st Street, P.O. Box 1839, Bloomfield, NM 87413. San Juan County Building Division: 100 South Oliver Drive, Aztec, NM 87410.
- Phone
- (505) 632-6304 (Bloomfield Planning & Zoning Director Crystal Martinez); (505) 632-6300 (City of Bloomfield main line); (505) 334-4313 (San Juan County Building Division, for building/electrical/plumbing/mechanical permits and inspections)
- Office hours
- City of Bloomfield Planning & Zoning: Monday–Thursday 7:00 am–5:30 pm; Friday closed. San Juan County Building Division: reachable at (505) 334-4313; all inspections must be requested at least 24 hours in advance (commercial and residential building permit applications both state 'a minimum of 24 hours is required for an inspection notification').
- Website
- Official site
Published scheduling rules
- Inspections must be requested at least 24 hours in advance by calling the San Juan County Building Division at (505) 334-4313. (New Residential Building Permit (New Construction / Addition / Accessory Building))
Inspection sequence
Applies to: New Residential Building Permit (New Construction / Addition / Accessory Building)
- 1
Footing
Forms and rebar in place prior to placement of concrete.
- 2
Foundation Wall / Monolithic Slab
Concrete block, ICF block, or concrete forms with reinforcement in place prior to placement of concrete.
- 3
Electrical Under Slab
Raceway runs prior to covering trench.
- 4
Plumbing Under Slab
DWV with test prior to covering trench; in-floor heat with air test.
- 5
Slab on Grade
After electrical and plumbing under-slab inspections, prior to placement of concrete.
- 6
Rough Electrical
Electric service, feeders, and branch circuits complete to termination.
- 7
Rough Plumbing
DWV top-out through roof with test, gas piping with test, water piping with test.
- 8
Rough Heating and Ventilation
Appliance vents through roof, trunk line and taps installed, combustion air provided, exhaust ducts complete.
- 9
Framing
After rough electrical, plumbing, and mechanical are complete and approved; windows in place; foundation and roof vents installed; air barrier requirements complete.
- 10
Insulation
Exterior walls complete; ceiling complete if batted.
- 11
Electrical Final
Panel board labeled, cover plate on, switches/outlets connected, fixtures in place.
- 12
Plumbing Final
Fixtures in place, water supply functional, gas appliances installed and connected.
- 13
Mechanical Final
Gas appliances connected and operational, vent terminations complete, grills in place, cooling units functional.
- 14
Building Final
Last inspection prior to occupancy approval; a Certificate of Occupancy is required before use or occupancy.
Applies to: Commercial Building Permit (New Construction / Addition / Alteration)
- 1
Footing
Forms and rebar in place prior to placement of concrete.
- 2
Foundation Wall / Monolithic Slab
Reinforcement in place prior to placement of concrete.
- 3
Rough Electrical / Plumbing / Mechanical
Rough-in trades complete to termination, with required tests.
- 4
Framing
After rough-in trades are complete and approved.
- 5
Fire Department Inspection
Applicable to commercial construction only.
- 6
Building Final
Last inspection prior to occupancy approval; a Certificate of Occupancy is required.
Applies to: Electrical Permit
- 1
Electrical Under Slab
Raceway runs prior to covering trench (new construction).
- 2
Rough Electrical
Service, feeders, and branch circuits complete to termination.
- 3
Electrical Final
Panel board labeled, cover plate on, switches/outlets connected, fixtures in place.
Applies to: Plumbing Permit
- 1
Plumbing Under Slab
DWV with test prior to covering trench; in-floor heat with air test.
- 2
Rough Plumbing
DWV top-out through roof with test, gas piping with test, water piping with test.
- 3
Plumbing Final
Fixtures in place, water supply functional, gas appliances installed and connected.
Applies to: Fire Sprinkler & Fire Alarm System Permit
- 1
Fire Protection System Inspection
San Juan County Fire Department/Fire Marshal's Office inspection of the installed sprinkler, alarm, extinguishing, standpipe, or cooking-hood system for code compliance; billed per the Inspection Fees table by square footage, with the initial inspection including one re-inspection.
- 2
Fire Department Inspection (new commercial construction)
Where the fire-protection system is installed as part of new commercial construction, this coincides with the Fire Department Inspection step already documented in this file's commercial-building-permit inspection sequence.
Applies to: Mechanical / HVAC Permit
- 1
Rough Heating and Ventilation
Appliance vents through roof, trunk line and taps installed, combustion air provided, exhaust ducts complete.
- 2
Mechanical Final
Gas appliances connected and operational, vent terminations complete, return/supply grills in place, cooling units functional.
Final inspection only: Change of Use / Certificate of Occupancy Permit, EV Charger / EVSE Installation Permit
Re-inspection fees
Sources & verification
Verified against official sources. Last reviewed 2026-07-18.
Fees, timelines, and adopted codes are researched from each jurisdiction's published records — see how we verify. Requirements change and vary by project, so always confirm the current details with the Bloomfield building department before you submit. PermitBase is an independent reference and is not affiliated with any government agency.
Bloomfield building permits
Get alerts for Bloomfield
We'll email you when Bloomfield's fees, documents, or codes change — not often.
We only use your email to send permit updates. No spam, unsubscribe anytime. Privacy.