Cave Creek building inspections
VerifiedInspection sequence, scheduling, and re-inspection fees for building permits in Cave Creek, Arizona.
Verified 2026-07-06 · Source
How to schedule
Inspections are requested through the building department below.
- Address
- 37622 N. Cave Creek Road, Cave Creek, AZ 85331
- Phone
- 480-488-1400 (Main); 480-488-6637 / 480-488-6622 (Building Official / Building Department); 480-488-6631 (Plans Examiner)
- Office hours
- Monday - Thursday, 7 a.m. to 5 p.m. All permit applications, plan reviews, inspection requests, and payments must be submitted through the Town's online portal, the SmartGov Community Platform (twn-cavecreek-az.smartgovcommunity.com/Public/Home) — effective as the Town's exclusive permitting channel per the Town's Online Permitting and Inspection Service notice.
- Website
- Official site
Published scheduling rules
- ALL permit applications, plan reviews, inspection requests, and payments must go through the Town's SmartGov Community Platform online portal — there is no walk-in or email-only permitting path described on the Town's site. (General)
Inspection sequence
Applies to: Residential Building Permit (New Construction)
- 1
Footing/Foundation
Before concrete pour; verifies footing depth/size, reinforcing steel, foundation plate bolting
- 2
Underslab Plumbing / Underfloor
Underground plumbing and underfloor space ventilation before slab or floor closure
- 3
Framing
Structural framing, shear/roof sheathing, connections per 2024 IRC and Town Design Criteria
- 4
Insulation
Verifies insulation R-values and Building Thermal Envelope per 2018 IECC (Chapters R1-R5, as adopted by the Town in place of the 2024 IECC residential chapters)
- 5
Drywall
Lath/gypsum board inspection before taping/finishing
- 6
Plumbing Rough / Mechanical / Fuel Gas Piping
Rough-in plumbing, mechanical, and gas piping trades
- 7
Final
All trades and final building inspection complete per approved plans
Applies to: Fire Sprinkler / Fire Alarm Permit
- 1
Underground / Rough Sprinkler Piping
Underground supply piping and rough sprinkler branch lines, required prior to the rough frame inspection per the Commercial Plan Submittal Guidelines
- 2
Hydrostatic Test
Pressure test of sprinkler piping per IFC/NFPA standards before concealment
- 3
Fire Alarm Rough-In
Alarm device and wiring placement, reviewed alongside the project's electrical rough-in inspection
- 4
Final / Acceptance Test
Final flow test and fire alarm functional/acceptance test verifying system operation before occupancy
Applies to: Plumbing Permit
- 1
Underslab / Underfloor Plumbing
Before concrete pour or floor closure — verify pipe slope, materials, cleanouts
- 2
Plumbing Rough Trade
After pipes installed, before walls closed
- 3
Plumbing Final
Fixtures connected, water heater relief valve and gas connections verified, no leaks
Applies to: Residential Addition / Remodel Permit
- 1
Footing/Foundation
Required before concrete pour for additions
- 2
Framing
Structural connections to existing structure
- 3
Final
Completed work verified against approved plans
Applies to: Swimming Pool / Spa Permit
- 1
Pre-Gunite / Steel
Rebar and plumbing placement before gunite/shotcrete for in-ground pools
- 2
Barrier/Fence
Verifies pool barrier compliance with A.R.S. § 36-1681 before pool is filled
- 3
Final
Completed pool/spa and barrier verified against approved plans
Applies to: Certificate of Occupancy for Change of Use Group
- 1
Change of Use Walkthrough
Verifies life-safety compliance (egress, occupant load, fire alarm/sprinkler coverage as applicable) for the new occupancy classification where no construction is involved
- 2
Final (where construction is involved)
Standard final building inspection against approved plans, applicable when the change of use includes construction/alteration work permitted under the Commercial Building Permit
Applies to: Commercial Sign Permit
- 1
Footing (freestanding/monument signs)
Verifies footing depth/size and anchor bolt placement before concrete pour for ground-mounted or monument signs
- 2
Final
Verifies completed sign installation, structural attachment, and electrical connections (if illuminated) against approved plans, per Town of Cave Creek Building & Fire Safety Department inspection stages (Zoning Ordinance § 9.5.D)
Applies to: Electrical Permit
- 1
Rough-In
Wiring, box placement, and panel connections before walls are closed
- 2
Final
Devices installed, panel labeled, protections (AFCI/GFCI) verified per 2023 NEC
Applies to: EV Charger / EVSE Permit
- 1
Rough-In
New circuit wiring, box placement, and panel connections before walls are closed, if applicable
- 2
Final
Charger unit installed, panel labeled, protections (AFCI/GFCI) verified per 2023 NEC
Applies to: Fence and Wall Permit
- 1
Footing
Required for engineered retaining walls before backfill
- 2
Final
Completed fence/wall verified against approved plans
Applies to: Mechanical / HVAC Permit
- 1
Mechanical Rough-In
Ductwork and equipment placement before walls closed
- 2
Final
Equipment operational, clearances and combustion air verified
Applies to: Residential Solar Photovoltaic (PV) Permit
- 1
Rough Electrical
Conduit runs, wire sizing, disconnect placement before energizing
- 2
Final
Panel mounting, racking attachment, roof penetration sealing, electrical connections, and interconnection point verified
Final inspection only: Demolition Permit, Re-Roofing Permit
Re-inspection fees
Sources & verification
Verified against official sources. Last reviewed 2026-07-06.
Fees, timelines, and adopted codes are researched from each jurisdiction's published records — see how we verify. Requirements change and vary by project, so always confirm the current details with the Cave Creek building department before you submit. PermitBase is an independent reference and is not affiliated with any government agency.