How to schedule
Inspections are requested through the building department below.
- Address
- Yuma City Hall, Second Floor, One City Plaza, Yuma, AZ 85364-1436
- Phone
- (928) 373-5163
- Office hours
- Monday - Thursday 7:00 AM - 5:00 PM; every other Friday 7:00 AM - 5:00 PM; closed on designated City holidays. Inspections: (928) 373-5170 (non-emergency, request by 3 p.m. for next-business-day scheduling); after-hours/emergency inspections (928) 373-5163.
- Website
- Official site
Published scheduling rules
- The Development Portal (Tyler EnerGov) allows online submission, payment, and inspection scheduling. (Residential Building Permit (New Construction))
- Confirm with Building Safety (928-373-5100 general line; Inspection@YumaAZ.gov for inspection scheduling) which specific Table 1-A fee bracket currently applies to a standalone EV charger circuit before applying, since no EV-specific line item is published (EV Charger / Electric Vehicle Charging Station Permit)
- Inspection requests received before 3 p.m. are scheduled for the next business day; plan on a 24-hour response time from field inspectors (per the City's Building Permits page). (Commercial Building Permit (New Construction / Addition))
- Inspection requests received before 3 p.m. are scheduled for the next business day (per the City's Building Permits page). (Commercial Tenant Improvement / Alteration Permit)
- Inspections (non-emergency) are scheduled by calling (928) 373-5170, emailing Inspection@YumaAZ.gov, or online through the Development Portal; after-hours/emergency inspections are scheduled by calling (928) 373-5163 for a nominal fee. Virtual inspections are available for specific installation types. (General)
- The Development Portal (Tyler EnerGov, at yumaaz-energovweb.tylerhost.net) is the City's online system for permit applications, payments, and inspection scheduling. (General)
Inspection sequence
Applies to: Commercial Building Permit (New Construction / Addition)
- 1
Foundation
Footings/foundation verified prior to concrete pour, including special inspection of compacted fill density where required (§ 150-016(X)/(Y))
- 2
Framing / Structural
Structural frame and connections per approved plans and 2024 IBC; lath and gypsum panel product inspection required (exception deleted by § 150-016(M))
- 3
Rough-In (Electrical / Plumbing / Mechanical)
Trade rough-ins under separate electrical, plumbing, and mechanical permits before concealment; all work must be inspected prior to covering (per the City's Building Permits page)
- 4
Fire Protection Systems
Fire sprinkler/alarm installations inspected under the separately tracked Commercial Fire Sprinkler permit; design must be Fire Department-approved in writing before installation (§ 150-016(G))
- 5
Final / Certificate of Occupancy
All required inspections completed and approved, then the building official issues the Certificate of Occupancy; no occupancy permitted until issued (per the City's Building Permits page)
Applies to: Fire Sprinkler / Fire Alarm Permit
- 1
Fire Protection System Plan Review and Written Approval
Where a design-criteria statement plus current fire flow test was submitted first, the complete design, plans, calculations and data must be submitted and approved IN WRITING by the Fire Department before any system installation begins (§ 131-16(H)). This written approval is a hard gate, not a courtesy.
- 2
Installation Inspection(s)
Inspections by the Community Risk Reduction Division, billed at the $75 per hour inspection rate that accompanies the $75 over-the-counter alteration permit (§ 131-16(G)). Acceptance testing is governed by the Chapter 9 referenced installation standards of the adopted 2024 IFC; Yuma’s amendments publish no Yuma-specific sprinkler or alarm inspection sequence, so no sequence is invented here.
- 3
Final Acceptance
Completed system verified against the Fire Department-approved design before the system is placed in service. Re-inspections are charged at $75 per hour where work is not ready or previously noted corrections have not been made (§ 131-16(G), Other Inspections and Fees note 2).
- 4
Ongoing Inspection, Testing and Maintenance Reporting
After acceptance, every ITM report on the system — compliant and non-compliant alike — must be filed electronically with the Yuma Fire Department in an AHJ-approved method (§ 131-16(X)). This is a continuing obligation on the property owner and the service company, not a one-time closeout item.
Applies to: Change of Use / Change of Occupancy Permit
- 1
Rough-In / Framing
Interior framing, structural modifications and trade rough-ins under separate electrical, plumbing and mechanical permits inspected before concealment; all work must be inspected prior to covering and moving on to the next step (City of Yuma Building Permits page). Inspection requests received before 3 p.m. are scheduled for the next business day.
- 2
Fire Protection Systems (where a retrofit is triggered)
Where the change of occupancy raises the hazard category and § 131-16(Z)(B) requires sprinklers, or where an IEBC Level 1 or higher alteration triggers the R-1/R-2 alarm requirements at § 131-16(DD)/(EE), the system is inspected by the Community Risk Reduction Division; the complete design must have been approved in writing by the Fire Department before installation began (§ 131-16(H)).
- 3
Final / Certificate of Occupancy
Once construction is complete and all required inspections have been completed and approved, the building official issues the Certificate of Occupancy. There shall be no occupancy of any building or structure until this certificate is issued (City of Yuma Building Permits page).
Applies to: Commercial Tenant Improvement / Alteration Permit
- 1
Rough-In / Framing
Interior framing, structural modifications, and trade rough-ins (under separate trade permits) inspected before concealment; all work must be inspected prior to covering (per the City's Building Permits page)
- 2
Fire Protection (if in scope)
Sprinkler/alarm modifications inspected under the Commercial Fire Sprinkler track; Fire Department written design approval required before installation (§ 150-016(G))
- 3
Final / Certificate of Occupancy
Completed work verified against approved plans; Certificate of Occupancy issued by the building official before occupancy of the new/changed space
Applies to: Plumbing Permit
- 1
Underground/Slab
Before concrete pour — pipe slope, materials, cleanouts, sewer depth (minimum 12 inches below grade per § 150-061(M))
- 2
Rough-In
After pipes installed, before walls closed
- 3
Final
Fixtures connected, water heater T&P verified, cleanouts exposed, no leaks
Applies to: Residential Building Permit (New Construction)
- 1
Foundation
Prior to concrete pour, verifying forms, rebar, and compliance with amended Table R301.2 design criteria
- 2
Framing
Structural framing per approved plans and 2024 IRC
- 3
Final
Completed construction inspected for code compliance prior to Certificate of Occupancy issuance
Applies to: Electrical Permit
- 1
Rough-In
Wiring, box placement, and service connections before walls are closed
- 2
Final
Devices installed and protections verified per NFPA 70 NEC 2020 Edition as locally amended
Applies to: EV Charger / Electric Vehicle Charging Station Permit
- 1
Rough-In (if applicable)
Wiring and panel/service connections before walls are closed, if the installation involves new concealed wiring
- 2
Final
Charger circuit, breaker sizing, and equipment connection verified per NFPA 70 NEC 2020 Edition as locally amended
Applies to: Mechanical / HVAC Permit
- 1
Rough-In
Ductwork and mechanical equipment rough-in before walls closed
- 2
Final
Equipment operational, condensate disposal, combustion air, and clearances verified
Applies to: Residential Addition / Remodel / Alteration Permit
- 1
Rough-In / Framing
Structural framing, connections to existing structure, per approved plans
- 2
Final
Completed work verified against approved plans prior to close-out
Applies to: Sign Permit
- 1
Sign Installation Inspection(s)
Chapter 154 publishes no sign-specific inspection sequence. It does establish that inspections occur and are re-called: § 154-17.07(C)(3)(b) assesses a re-inspection fee “when the work for which the inspection is called is not complete, or when corrections previously noted have not been made”. The number, order and trigger points of sign inspections are not published — confirm with Building Safety at (928) 373-5163 rather than assuming a sequence from another jurisdiction.
- 2
Electrical Inspection (illuminated signs)
Work performed under the separate electrical permit required by § 154-17.07(B)(1)(d) is inspected under the electrical code adopted at § 150-076 (NFPA 70 National Electrical Code, 2020 Edition, with the 2006 ICC Electrical Code administrative provisions). All work must be inspected prior to covering (City of Yuma Building Permits page).
Applies to: Solar Photovoltaic (PV) Permit
- 1
Rough Electrical
Conduit runs, wire sizing, and disconnect placement before energizing
- 2
Final
Panel mounting, racking attachment, roof penetration sealing, electrical connections, and inverter verified
Final inspection only: Demolition Permit, Fence and Wall Permit, Re-Roofing Permit
Re-inspection fees
Other Inspections and Fees (if no specific Unit Fee Schedule bracket applies) · Yuma City Code § 150-077(L), Table 1-A — the tipsAndGotchas flags a possible unverified 2025 rate increase to $75/$150… Show full citationHide
Other Inspections and Fees (if no specific Unit Fee Schedule bracket applies) · Yuma City Code § 150-077(L), Table 1-A — the tipsAndGotchas flags a possible unverified 2025 rate increase to $75/$150 per hour for this same 'Other Inspections' line in the Building Permit Fee Table; the Electrical Table's published rate remains $50/hour as of the amlegal.com-hosted code textRe-inspection Fee — TWO OFFICIAL FIGURES CONFLICT · Two provisions of the code conflict on the re-inspection fee, and neither is averaged nor silently chosen here. Show full citationHide
Re-inspection Fee — TWO OFFICIAL FIGURES CONFLICT · Two provisions of the code conflict on the re-inspection fee, and neither is averaged nor silently chosen here. § 154-17.07(C)(3)(b) states a re-inspection fee “shall be $15”, assessed when the work called for inspection is not complete or previously noted corrections have not been made. Table 1-A at § 150-016(I), as amended by Ord. O2025-033 passed 10-1-25, instead sets “Reinspection fees of $75 per hour” (or the total hourly cost to the jurisdiction, whichever is greater). Both texts are live in the same code version (2026 S-74); the sign-chapter figure descends from ordinance history predating the 2025 building-fee update. Confirm which applies with Building Safety at (928) 373-5163.Other Inspections and Fees (fire) · Yuma City Code § 131-16(G), “Other Inspections and Fees” notes 1 to 6. Show full citationHide
Other Inspections and Fees (fire) · Yuma City Code § 131-16(G), “Other Inspections and Fees” notes 1 to 6. Every hourly rate carries the qualifier “or the total hourly cost to the jurisdiction, whichever is the greatest”, which includes supervision, hourly wages and fringe benefits of the employee involved; actual costs include administrative and overhead costs. The code also warns that “staffing may not always be available to accommodate these inspection requests.”Sources & verification
Verified against official sources. Last reviewed 2026-07-03.
Fee schedules
Online permit portal
Codes & ordinances
Department & other records
Fees, timelines, and adopted codes are researched from each jurisdiction's published records — see how we verify. Requirements change and vary by project, so always confirm the current details with the Yuma building department before you submit. PermitBase is an independent reference and is not affiliated with any government agency.
Yuma building permits
Get alerts for Yuma
We'll email you when Yuma's fees, documents, or codes change — not often.
We only use your email to send permit updates. No spam, unsubscribe anytime. Privacy.