Breckenridge building inspections
VerifiedInspection sequence, scheduling, and re-inspection fees for building permits in Breckenridge, Colorado.
Verified 2026-07-06 · Source
How to schedule
Inspections are requested through the building department below.
- Address
- 150 Ski Hill Road, 2nd Floor, PO Box 168, Breckenridge, CO 80424
- Phone
- (970) 453-3180
- Office hours
- Monday-Thursday 8:00am-5:00pm, Friday 8:00am-12:00pm; closed major holidays
- Website
- Official site
Inspection sequence
Applies to: Residential Building Permit (New Construction)
- 1
Foundation
Before concrete pour, per 40-inch minimum frost depth (or ASCE 32 design); frost report required if poured Nov 1-May 1 or during a freeze window
- 2
Rough Frame
Framing complete before cover
- 3
Rough Plumbing / Rough Electrical / Rough Mechanical
Trade rough-ins before concealment; separate sub-permits required
- 4
Final Building Inspection
Requires prior sign-off from Finance (if valuation over $100K), Upper Blue Sanitation District, Red White & Blue Fire, and Planning/Engineering/Water/Streets as applicable; certificate of occupancy issued via email upon passing
Applies to: Commercial Building Permit (New Construction)
- 1
Foundation
Before pour; 40-inch minimum frost depth (or ASCE 32 design) per Town Code 8-1-4; frost report required Nov 1-May 1 or during any freeze window
- 2
Rough Frame / Rough Trades
Framing and plumbing/electrical/mechanical rough-ins (under separate sub-permits) before concealment; inspections are scheduled by the general contractor through the user portal — requests submitted before 11pm can be completed as soon as the next business day
- 3
Final Building Inspection
Requires prior final approvals from Finance (if valuation over $100K), Red White & Blue Fire District, and — where their sign-off applied — Upper Blue Sanitation District, Environmental Health, Planning, Engineering, Water, and Streets; certificate of completion issued via email upon passing
Applies to: Residential Addition / Remodel Permit
- 1
Rough Frame
Framing/structural modifications complete before cover
- 2
Rough Plumbing / Electrical / Mechanical
Trade rough-ins before concealment (if applicable to scope)
- 3
Final Building Inspection
Requires sign-off from Finance (if over $100K valuation), UBSD, RW&B Fire, and Planning as applicable; certificate of completion issued via email
Applies to: Solar PV Permit
- 1
Rough Inspection
Wire/conduit routing verified before concealment
- 2
Final Electrical Inspection
Typically same day as Final Building Inspection; rapid shutdown test may be required
- 3
Final Building Inspection
Racking, roof penetrations verified; final painting of exterior conduit/junction boxes/panels required; both finals needed for full approval
Applies to: Commercial Remodel / Tenant Finish Permit
- 1
Rough Frame / Rough Trades
Structural modifications and plumbing/electrical/mechanical rough-ins (under separate sub-permits) before concealment; scheduled by the general contractor via the user portal — requests before 11pm can be completed as soon as the next business day
- 2
Final Building Inspection
Requires prior final approvals from Red White & Blue Fire District, Finance (if valuation over $100K), and — where sign-off was required at application — Upper Blue Sanitation District and Environmental Health, plus Planning/Engineering/Water/Streets if in the project workflow; certificate of completion issued via email
Applies to: Electrical Permit
- 1
Rough Electrical
Wiring and panel installed, before concealment
- 2
Final Electrical
System energized and verified; for solar/hot tub work, Final Electrical and Final Building inspections typically occur the same day
Applies to: Fire Sprinkler and Fire Alarm System Permit
- 1
Rough-In Inspection (Sprinkler and/or Fire Alarm)
Scheduled with RWB before concealment
- 2
Final Inspection (Sprinkler and/or Fire Alarm)
Performed by RWB's Fire Marshal's office
Applies to: Mechanical / HVAC Permit
- 1
Rough Mechanical
Ductwork, flues, and equipment installed but not concealed
- 2
Final Mechanical
Equipment operational; combustion air and venting verified
Applies to: Plumbing Permit
- 1
Rough Plumbing
Underground and rough-in plumbing installed, before concealment
- 2
Final Plumbing
Fixtures connected, no leaks, proper venting verified
Applies to: Roofing Permit (Re-Roof)
- 1
Underlayment and Flashing Inspection
Underlayment, valley flashing, and ventilation openings verified before roof covering installation is completed
- 2
Final Building Inspection
Completed roof — Class A covering, snow-shed design, and all CWRC compliance items verified; drone aerial photography may be used
Final inspection only: Change of Use Permit (Development Permit), EV Charger / EVSE Permit, Sign Permit
Re-inspection fees
Sources & verification
Verified against official sources. Last reviewed 2026-07-06.
Fee schedules
Applications & forms
Checklists & handouts
Online permit portal
Codes & ordinances
Department & other records
Fees, timelines, and adopted codes are researched from each jurisdiction's published records — see how we verify. Requirements change and vary by project, so always confirm the current details with the Breckenridge building department before you submit. PermitBase is an independent reference and is not affiliated with any government agency.
Breckenridge building permits
Get alerts for Breckenridge
We'll email you when Breckenridge's fees, documents, or codes change — not often.
We only use your email to send permit updates. No spam, unsubscribe anytime. Privacy.