Fort Lupton building inspections
Inspection sequence, scheduling, and re-inspection fees for building permits in Fort Lupton, Colorado.
Reviewed 2026-07-06 · Source
How to schedule
Inspections are requested through the building department below.
- Address
- 1200 Dexter Street, Unit W13, Fort Lupton, CO 80621 (mailing: 130 S McKinley Ave, Fort Lupton, CO 80621)
- Phone
- 720-928-4003
- Office hours
- Not published on the Building Department page as of this review. Key staff direct lines: Jonathan Gesick (Building Official, SAFEbuilt contract) 970-518-5269 jgesick@safebuilt.com; Jose Gonzalez (Building Official II, ProCode Inc. contract) 970-305-3161 jgonzalez@procodeinc.net (also reachable at coemail@safebuilt.com per the New Construction Requirements page); Shannon DeVries (Permit Technician I) 720-466-6104 buildingdept@fortluptonco.gov; Todd Hodges (Planning Director) 720-466-6106 thodges@fortluptonco.gov.
- Website
- Official site
Published scheduling rules
- A failed water heater may be replaced immediately in an emergency, provided the permit application is submitted the next business day. (Furnace / Water Heater Replacement Permit)
- Emergency replacements (e.g., failed water heater) may be installed before permit issuance provided the application is submitted the next business day (Furnace / Water Heater Replacement Permit)
- Permits are valid for 6 months (180 days), extendable by continuing to request inspections; one formal extension and up to 3 amendments/revisions (each a flat $85.00 fee) are allowed per permit. (General)
Inspection sequence
Applies to: Accessory Dwelling Unit (ADU) Permit
- 1
Foundation
Prior to concrete pour (new-construction ADU)
- 2
Framing
Structural framing complete before cover
- 3
Rough Electrical / Plumbing / Mechanical
Trade rough-ins before concealment
- 4
Final Inspection
All work complete per approved plans
Applies to: Residential Addition / Interior Remodel Permit
- 1
Foundation (additions with new footings only)
Prior to concrete pour
- 2
Rough Frame
Framing complete, connection to existing structure verified
- 3
Rough Electrical / Plumbing / Mechanical
Trade rough-ins before concealment
- 4
Final Inspection
All work complete per approved plans
Applies to: Residential Building Permit (New Construction)
- 1
Foundation
Prior to concrete pour, per engineered foundation plan and soils report
- 2
Framing
Structural framing, trusses/joists complete before cover
- 3
Rough Electrical / Plumbing / Mechanical
Trade rough-ins before concealment
- 4
Final Inspection
All work complete; Residential Energy Compliance Certificate and Improvement Location Certificate (ILC) submitted prior to Certificate of Occupancy
Applies to: Commercial Tenant Improvement Permit
- 1
Rough Frame / Structural
Framing and any structural modifications before cover
- 2
Rough Electrical / Plumbing / Mechanical
Trade rough-ins for the tenant space before concealment
- 3
Final Inspection
All work complete; Certificate of Occupancy issued 48-72 hours after final approval
Applies to: Deck / Covered Patio / Porch Permit
- 1
Footing / Pier
Prior to concrete pour, for decks/patios requiring footings or piers
- 2
Framing
Deck framing, ledger attachment, and railing before final
- 3
Final Inspection
Guardrails, stair geometry, and attachment to primary structure verified
Applies to: Electrical Permit
- 1
Rough Electrical
Wiring and panel installed before concealment
- 2
Final Inspection / Meter Release
Devices installed, panel labeled, system energized; Permanent or Temporary Meter Release inspection required
Applies to: EV Charger / Electric Vehicle Charging Station Permit
- 1
Rough Electrical
Wiring and panel/circuit installed before concealment
- 2
Final Inspection / Meter Release
Charger installed, panel labeled, system energized; Permanent or Temporary Meter Release inspection required if the installation involves a service/meter change
Applies to: Mechanical / HVAC Permit
- 1
Rough Mechanical
Ductwork, flues, and equipment placement before concealment (new construction/addition scope only)
- 2
Final Inspection
Equipment operational, combustion air and venting verified
Applies to: Plumbing Permit
- 1
Rough Plumbing
Pipe, drain, waste, and vent installation before concealment
- 2
Final Inspection
Fixtures connected, no leaks, proper venting verified
Applies to: Rooftop Solar Photovoltaic (PV) Permit
- 1
Rough Electrical
Conduit runs, wire sizing, and disconnect placement before cover
- 2
Final Inspection / Meter Release
Racking, roof penetrations, and electrical connections verified; meter release inspection required for interconnection
Final inspection only: Demolition Permit, Furnace / Water Heater Replacement Permit, Reroof Permit
Re-inspection fees
Sources & verification
Key facts verified against official sources. Last reviewed 2026-07-06.
Fees, timelines, and adopted codes are researched from each jurisdiction's published records — see how we verify. Requirements change and vary by project, so always confirm the current details with the Fort Lupton building department before you submit. PermitBase is an independent reference and is not affiliated with any government agency.
Fort Lupton building permits
Get alerts for Fort Lupton
We'll email you when Fort Lupton's fees, documents, or codes change — not often.
We only use your email to send permit updates. No spam, unsubscribe anytime. Privacy.