Skip to main content
PermitBase

Electrical Permit in Boulder City, Nevada

Required for electrical installation, alteration, or repair work in Boulder City, governed by the 2017 National Electrical Code (NEC) with Southern Nevada Building Code Amendments.

Verified 2026-07-03 · Source

When you need this permit

  • Electrical permit required for installation, alteration, or repair of hard-wired electrical systems
  • Governed by the 2017 NEC with Southern Nevada Building Code Amendments
  • Completed Electrical Load Calculation Worksheet required as backup documentation
  • Service changes on a same-for-same basis qualify for the Express Permit (no-plans) track
  • Fees for electrical work bundled with a building permit are calculated as 18.00% of the base building permit fee; standalone electrical permits use Table C flat fees

Required documents

Check off what you have — your progress is saved on this device.

Not ready yet0 of 2 required documents checked.

This checker covers one permit. A full project usually triggers several — our checklist will assemble all of them, free →

Fee schedule

Permit Issuance2026 Administrative Code, Table C
$40.00
Receptacle, switch and lighting outlet (each)2026 Administrative Code, Table C
$1.00
Appliance Outlets, Residential or Commercial (each)2026 Administrative Code, Table C
$5.00
Service (same-for-same), 600V or less and not over 200 amperes, includes Temporary Power (each)2026 Administrative Code, Table C
$40.00
Service (same-for-same), 600V or less and over 200 up to 1,000 amperes (each)2026 Administrative Code, Table C
$60.00
Service (same-for-same), over 600V and/or over 1,000 amperes (each)2026 Administrative Code, Table C
$85.00
Electrical permit bundled with a building permit2026 Administrative Code, Section 110.2(I)(1)
18.00% of the base building permit fee (Table A)
Service Change (Up to 200 AMP) — per common permit fee flyer2020 Fee Schedule, 'Common Permit Fees' box
$80.00
Temporary Power2020 Fee Schedule, 'Common Permit Fees' box (includes $40 issuance plus $250 utility connection fee per Table H)
$290.00

Review timeline

Plan reviewBoulder City’s published plan-review target
7–14 business days

How long did your Electrical Permit permit actually take in Boulder City?

Anonymous — one question, no email. Answers are combined and only shown once at least 5 people have reported.

Inspection process

  1. 1

    Rough-In

    Wiring and box placement before wall closure

  2. 2

    Final

    Devices installed and panel labeled per 2017 NEC

See the full Boulder City inspection guide — scheduling & re-inspection fees →

Tips

  • The plan review timeframe for a first review of an Electrical permit is 1-2 weeks. Source: City of Boulder City Electrical Permit Submittal Checklist (02/16/2021 V1).
  • A same-for-same service change (up to 200 amp) is one of six Express Permit types that does not require plans.

Frequently asked questions

Boulder City requires an electrical permit for: Electrical permit required for installation, alteration, or repair of hard-wired electrical systems; Governed by the 2017 NEC with Southern Nevada Building Code Amendments; Completed Electrical Load Calculation Worksheet required as backup documentation; Service changes on a same-for-same basis qualify for the Express Permit (no-plans) track; Fees for electrical work bundled with a building permit are calculated as 18.00% of the base building permit fee; standalone electrical permits use Table C flat fees. If your project isn't listed, confirm with City of Boulder City Community Development Department, Building and Safety Division at (702) 293-9282 before starting work.

In Boulder City, the published Permit Issuance is: $40.00. Additional published fees: Receptacle, switch and lighting outlet (each) — $1.00; Appliance Outlets, Residential or Commercial (each) — $5.00; Service (same-for-same), 600V or less and not over 200 amperes, includes Temporary Power (each) — $40.00; Service (same-for-same), 600V or less and over 200 up to 1,000 amperes (each) — $60.00; Service (same-for-same), over 600V and/or over 1,000 amperes (each) — $85.00; Electrical permit bundled with a building permit — 18.00% of the base building permit fee (Table A); Service Change (Up to 200 AMP) — per common permit fee flyer — $80.00; Temporary Power — $290.00. These are the jurisdiction's own published figures — see the fee schedule table and source citations on this page.

Boulder City's published plan-review target for an electrical permit is 7–14 business days.

You'll need: Electrical Permit Submittal Checklist; Electrical Load Calculation Worksheet. See the required-documents checklist on this page for details on each.

Boulder City requires 2 inspection(s) for an electrical permit, in order: Rough-In, Final. Schedule each through City of Boulder City Community Development Department, Building and Safety Division ((702) 293-9282).

Apply through City of Boulder City Community Development Department, Building and Safety Division at 401 California Avenue, Boulder City, NV 89005. Phone: (702) 293-9282, email: buildingpermits@bcnv.org. Office hours: Monday through Thursday, 7:00 a.m. to 6:00 p.m. (excluding holidays); applications submitted after office hours are processed the next available work day. Inspection scheduling hotline: (702) 293-9327 or buildinginspections@bcnv.org; inspection requests must be received by 3:30 p.m. for next-business-day scheduling (no Friday/weekend/holiday inspections).. Official information: https://www.bcnv.org/163/Building-Permits.

Boulder City, Nevada has adopted: Nevada has no mandatory statewide building code; NRS 701.220 requires the Nevada Governor's Office of Energy (GOE) to adopt, on a triennial basis, the most recently published International Energy Conservation Code (IECC) as a statewide ENERGY floor only — local governments may not adopt an energy code less stringent than the GOE-adopted IECC edition, but building-code editions for structural/life-safety codes vary city-by-city under home rule. The 2024 IECC was adopted by the GOE effective August 18, 2024, as the current statewide energy floor. Source: NRS 701.220 (Nevada Revised Statutes, Chapter 701 — Energy Policy), https://www.leg.state.nv.us/nrs/nrs-701.html; Nevada Governor's Office of Energy, Building Energy Codes / State Adoption Status, https://www.energy.nv.gov/programs/building-energy-codes/state-adoption-status/. Confirm your city's specific adopted energy-code edition — Boulder City's own adopted edition is documented separately below and is older than the current statewide floor edition (a home-rule city choice, not a floor violation, since IECC 2018 was the floor at the time of Boulder City's last code-cycle adoption).; Boulder City runs its own independent building-permit program (Community Development Department, Building and Safety Division) — it is NOT administered by Clark County. Verified via the City's official Building and Safety Division page and the City's own Administrative Code, fee schedule, and permit-submittal-checklist library, all published on bcnv.org. Source: City of Boulder City Building and Safety Division, https://www.bcnv.org/163/Building-Permits; 2018 International Building Code (IBC), with Southern Nevada Building Code Amendments — applies to buildings other than single-family residential homes and townhomes (2026 Administrative Code Section 101.5.1). Source: City of Boulder City Permit Fee Schedule and Valuation Table (eff. 8/3/2020) 'Currently Adopted Codes/Standards' list, and Residential New Construction (Custom) Permit Submittal Checklist (02/16/2021 V1) 'Applicable Codes' section; 2018 International Existing Building Code (IEBC) — governs additions/modifications to existing buildings (2026 Administrative Code Section 101.5.2); 2018 International Residential Code (IRC), with Southern Nevada Building Code Amendments — applies to single-family homes and townhomes (2026 Administrative Code Section 101.5.3); 2018 Uniform Mechanical Code (UMC), with Southern Nevada Building Code Amendments — Nevada's Southern Nevada jurisdictions use the Uniform Mechanical Code, not the International Mechanical Code; 2018 Uniform Plumbing Code (UPC), with Southern Nevada Building Code Amendments — not the International Plumbing Code; 2017 National Electrical Code (NEC), with Southern Nevada Building Code Amendments; 2018 International Swimming Pool and Spa Code (ISPSC), with Southern Nevada Building Code Amendments; 2018 International Energy Conservation Code (IECC), with Southern Nevada Building Code Amendments — this is Boulder City's own locally adopted energy-code edition (older than the current 2024 IECC statewide floor under NRS 701.220; confirm current status with Building and Safety before relying on this edition for new submittals); 2012 International Fire Code (IFC) per the 2020 Fee Schedule flyer; the 2026 Administrative Code Section 101.5.9 separately lists 'the currently adopted International Fire Code' generically without repeating the edition year — the 2012 edition is the last edition year found published by the City; Southern Nevada Amendments apply to all the above codes per 2026 Administrative Code Section 101.5.10 ('the provisions of the currently adopted Southern Nevada Amendments shall apply to all matters of all of the above mentioned codes'); City of Boulder City Building and Safety Division Administrative Code, 2026 edition — the local administrative/procedural code (permit application, fees, inspections, exemptions); contains substantial copyrighted material from the 2012 IBC per its title page. Source: https://www.bcnv.org/DocumentCenter/View/16731/2026-Building-and-Safety-Division-Administrative-Codepdf; All of the above code editions and amendment references are confirmed current via the City's Permit Submittal Checklists (each dated 02/16/2021 V1, and independently re-served live from bcnv.org as of this review) for Residential New Construction (Custom), Electrical, Plumbing, Mechanical, Demolition, Fence and Retaining Wall, Renewable Energy System Residential PV, and Residential Accessory Building — all list the identical 2018/2018/2018/2017/2018 code-edition set with Southern Nevada Amendments, corroborating the 2020 Fee Schedule flyer. Local amendments apply — see the Boulder City overview page for the full list.

Sources & verification

Verified against official sources. Last reviewed 2026-07-03.

Fees, timelines, and adopted codes are researched from each jurisdiction's published records — see how we verify. Requirements change and vary by project, so always confirm the current details with the Boulder City building department before you submit. PermitBase is an independent reference and is not affiliated with any government agency.