Saratoga Springs building inspections
VerifiedInspection sequence, scheduling, and re-inspection fees for building permits in Saratoga Springs, Utah.
Verified 2026-07-04 · Source
How to schedule
Inspections are requested through the building department below.
- Address
- 319 S Saratoga Rd, Saratoga Springs, UT 84045
- Phone
- (801) 766-6507
- Office hours
- Mon–Thu 7:00 AM – 6:00 PM; Fri 8:00 AM – 5:00 PM (limited inspections on Fridays)
- Website
- Official site
Inspection sequence
Applies to: Residential Addition / Remodel Permit
- 1
Framing
Wall framing, fire blocking, egress window openings and well depths verified.
- 2
MEP Rough-In
Electrical, plumbing, and HVAC rough-ins before walls closed.
- 3
Insulation
Insulation on exterior walls, vapor barrier placement.
- 4
Final
Drywall, fixtures, smoke/CO detectors, all finishes complete per saratogasprings-ut.gov/225 requirements.
Applies to: Residential Building Permit
- 1
Foundation / Footing
Before concrete pour — verify forms, rebar, frost protection depth (30 inches minimum per saratogasprings-ut.gov/223).
- 2
Framing
After framing, sheathing, and MEP rough-in, before insulation or wall cover.
- 3
Insulation
After insulation installed, before drywall.
- 4
Final / Certificate of Occupancy
All work complete, egress and life-safety items verified before occupancy.
Applies to: Commercial Building Permit
- 1
Foundation / Footing
Before concrete pour — verify forms, rebar, frost protection depth (30 inches minimum per saratogasprings-ut.gov/223).
- 2
Framing
After framing, sheathing, and MEP rough-in, before insulation or wall cover.
- 3
Final / Certificate of Occupancy
All work complete, egress and life-safety items verified before occupancy.
Applies to: Electrical Permit
- 1
Rough-In
After wiring installed, before walls closed.
- 2
Service / Panel
Panel installation, grounding electrode system, service entrance conductors.
- 3
Final
All devices installed, GFCI/AFCI protection verified, panel labeled.
Applies to: Commercial Tenant Improvement / Tenant Finish Permit
- 1
Framing / Structural
Where structural or MEP changes are part of the scope, before close-in.
- 2
Final / Certificate of Occupancy
All work complete, egress and life-safety items verified before occupancy.
Applies to: Mechanical / HVAC Permit
- 1
Rough-In
Ductwork and gas piping installed, before walls closed.
- 2
Final
Equipment operational, gas pressure tested, combustion air verified.
Applies to: Plumbing Permit
- 1
Rough-In
After pipes installed, before walls closed.
- 2
Final
All fixtures connected, no leaks, proper venting verified.
Applies to: Roofing Permit
- 1
Deck / Substrate
After tear-off — verify sheathing condition before proceeding.
- 2
Final
Completed roof — flashing, drip edge, nailing pattern, and ventilation verified.
Re-inspection fees
Sources & verification
Verified against official sources. Last reviewed 2026-07-04.
Fees, timelines, and adopted codes are researched from each jurisdiction's published records — see how we verify. Requirements change and vary by project, so always confirm the current details with the Saratoga Springs building department before you submit. PermitBase is an independent reference and is not affiliated with any government agency.
Saratoga Springs building permits
Get alerts for Saratoga Springs
We'll email you when Saratoga Springs's fees, documents, or codes change — not often.