Fire Sprinkler System Permit (Wyoming State Fire Marshal) — Unincorporated Laramie County, Wyoming · Requirements sheet
Verified 2026-07-22 · Source: https://wsfm.wyo.gov/fire-prevention/plan-review
PermitBase is an independent reference and is not affiliated with any government agency. Requirements change and vary by project — confirm current details with the building department before you submit.
Fire Sprinkler System Permit (Wyoming State Fire Marshal) in Unincorporated Laramie County, Wyoming
Unlike building and electrical permits, fire protection sprinkler system plan review and permitting in unincorporated Laramie County is NOT administered by the Laramie County Building Department. The county's own Building Permit Handouts and Fee Schedule page directs applicants to 'contact the State Fire Marshall Office for all Fire related permits.' Installation, addition, or alteration of a fire protection sprinkler system requires plan review by the Wyoming Department of Fire Prevention and Electrical Safety (the state agency housing the Wyoming State Fire Marshal) under W.S. 35-9-108, regardless of project size or valuation — this is the reverse delegation pattern from electrical, which Laramie County enforces locally.
Verified 2026-07-22 · Source
When you need this permit
- Plan review is required for installation, addition, or alteration of a fire protection sprinkler system 'regardless of size or valuation,' per W.S. 35-9-108 and the WSFM Plan Review Information page
- Plans must be submitted to the Department of Fire Prevention and Electrical Safety for review and approval before any work commences, via the Wyoming State Fire Marshal's eLicensing, ePermit, and ePayment Portal
- Plans for fire protection sprinkler systems designed by a NICET III or greater professional must be prepared under the direct supervision of a design professional registered to practice engineering in Wyoming; if the system is a manufactured, pre-engineered system, evidence of this must be submitted for verification (WSFM Department Rules, Chapter II, Section 1(c)(ii))
- Four (4) sets of plans and one (1) set of specifications must be submitted, or one (1) set of CAD drawings in DWF format if filed electronically — electronic filing is preferred for sprinkler and alarm systems (WSFM Department Rules, Chapter II, Section 1(d)(i))
- A separate Department-provided form and packet is required specifically for fire protection sprinkler systems, distinct from the general building plan review packet (WSFM Department Rules, Chapter II, Section 1(e))
- Plans must be drawn to scale and include a site plan showing property lines, streets/alleys, fire access roads, and the proposed building location
- Plans for fire sprinkler systems are submitted as successive-phase plans after the initial building plans are approved, if the overall project is phased
- After Department acceptance, construction must commence within 180 days; work may not be suspended or abandoned for more than 180 days, or the plan approval becomes null and void
- This is a STATE-issued permit/plan approval, separate from and in addition to any Laramie County building permit required for the associated construction project
Required documents
Check off what you have — your progress is saved on this device.
Not ready yet — 0 of 3 required documents checked.
This checker covers one permit. A full project usually triggers several — our paid checklist will assemble all of them, from $29 →
Fee schedule
Review timeline
Inspection process
- 1
Plan Review Fire Inspection
WSFM performs plan review fire inspections during construction to verify the installed sprinkler system matches the approved, stamped plan set
- 2
Final / Certificate of Occupancy or Letter of Compliance
Upon passing all required inspections, WSFM issues a Certificate of Occupancy or Letter of Compliance
See the full Unincorporated Laramie County inspection guide — scheduling & re-inspection fees →
Tips
- GOTCHA: Do not direct fire sprinkler permit questions to the Laramie County Building Department — the county's own Building Permit Handouts and Fee Schedule page explicitly instructs applicants to 'contact the State Fire Marshall Office for all Fire related permits' (wsfm.wyo.gov). This is the opposite delegation pattern from electrical, which Laramie County enforces locally under its own delegated authority.
- Plans for fire sprinkler systems must be submitted as successive-phase plans after the initial building plans are approved if the project is phased (WSFM Department Rules, Chapter II, Section 2(c)).
- WSFM may issue a temporary certificate of occupancy or temporary letter of compliance if occupancy will not pose an unreasonable risk, listing any outstanding code items and an expiration date by which they must be met.
Frequently asked questions
Sources & verification
Verified against official sources. Last reviewed 2026-07-22.
Fees, timelines, and adopted codes are researched from each jurisdiction's published records — see how we verify. Requirements change and vary by project, so always confirm the current details with the Unincorporated Laramie County building department before you submit. PermitBase is an independent reference and is not affiliated with any government agency.
Other permits in Unincorporated Laramie County
Fire Sprinkler System Permit (Wyoming State Fire Marshal) in other cities
Compare fire sprinkler system permit (wyoming state fire marshal) fees across Wyoming →
Look up this fee in a different city →
Now live
Build your Unincorporated Laramie County project checklist
Describe your project once and get every permit, document, and fee it triggers in Unincorporated Laramie County — in one checklist. Sign up and pay once to generate it, or go unlimited with Pro.
Get started →