Skip to main content
PermitBase

Green River building inspections

Verified

Inspection sequence, scheduling, and re-inspection fees for building permits in Green River, Wyoming.

Verified 2026-07-01 · Source

How to schedule

Inspections are requested through the building department below.

Address
50 E 2nd North Street, Green River, WY 82935
Phone
(307) 872-6140
Office hours
Monday through Friday, 8:00 a.m. to 5:00 p.m.

Published scheduling rules

  • Required inspections must be scheduled with Development Services a minimum of 24 hours in advance, (307) 872-6140 (Change of Use / Change of Occupancy Permit)

Inspection sequence

Applies to: Residential Addition / Remodel Permit

  1. 1

    Foundation (if new footings)

    Before concrete pour, if the addition involves new footings

  2. 2

    Framing

    After framing, before insulation or wall cover

  3. 3

    MEP Rough-In

    Electrical, plumbing, mechanical rough-in as applicable before walls closed

  4. 4

    Final

    All work complete per approved plans

Applies to: Residential Building Permit (New Construction)

  1. 1

    Foundation / Footing

    Before concrete pour — footings must extend below the 42-inch local frost line

  2. 2

    Framing

    After framing complete, before insulation or wall cover

  3. 3

    MEP Rough-In

    Mechanical, electrical, and plumbing rough-in before walls closed; electrical rough-in performed by the City under Home Rule

  4. 4

    Final

    All work complete, ready for certificate of occupancy

Applies to: Commercial Tenant Improvement Permit

  1. 1

    Framing / Structural

    After framing, before wall cover

  2. 2

    MEP Rough-In

    Mechanical, electrical, plumbing rough-in before walls closed

  3. 3

    Final / Certificate of Occupancy

    All work complete, life-safety systems verified

Applies to: Solar PV Permit

  1. 1

    Rough Electrical

    Conduit runs, wire sizing, disconnect placement before cover

  2. 2

    Final — Structural/Racking

    Panel mounting and roof penetration sealing verified

  3. 3

    Final — Electrical

    Interconnection point and system energization verified by City inspection

Applies to: Demolition Permit

  1. 1

    Pre-Demolition Utility Shutoff Verification

    City of Green River Building Department verifies gas, electric, and water/sewer are properly shut off before demolition begins

  2. 2

    Final

    Site cleared, backfilled, leveled, and debris removed within 60 days after demolition

Applies to: Electrical Permit

  1. 1

    Rough-In

    Wiring and boxes installed, before walls closed

  2. 2

    Final

    All devices installed and energized, verified by City inspection prior to certificate of occupancy

Applies to: EV Charger / Electric Vehicle Charging Station Permit

  1. 1

    Rough Electrical

    Conduit runs, wire sizing, and disconnect placement verified before cover

  2. 2

    Final — Electrical

    New circuit, breaker sizing, and disconnect verified before the charger is energized

Applies to: Fire Sprinkler & Fire Alarm System Permit (Wyoming State Fire Marshal's Office)

  1. 1

    Rough-In Inspection

    Fire sprinkler/alarm system rough installation (piping, wiring, devices) verified before concealment, per the WSFM-approved plans

  2. 2

    Final Acceptance Test

    System functional/acceptance test (hydrostatic test for sprinkler systems; device-by-device test for alarm systems) witnessed prior to final sign-off

Applies to: Mechanical / HVAC Permit

  1. 1

    Rough-In / Equipment

    Equipment and ductwork installed before walls closed

  2. 2

    Final

    Equipment operational, venting and combustion air verified

Applies to: Plumbing Permit

  1. 1

    Underground / Rough-In

    Before concealment — pipe slope, materials, connections verified

  2. 2

    Final

    All fixtures connected, no leaks, proper venting verified

Re-inspection fees

Electrical PermitRe-inspection Fee · Required when the inspector must return for a repeated violation of the same code; paid prior to the third inspection and every re-inspection thereafter.
$50.00
EV Charger / Electric Vehicle Charging Station PermitRe-inspection Fee · Required when the inspector must return for a repeated violation of the same code; paid prior to the third inspection and every re-inspection thereafter.
$50.00
Fire Sprinkler & Fire Alarm System Permit (Wyoming State Fire Marshal's Office)Other WSFM inspection/plan-review fees · Minimum charges apply (two-hour minimum for after-hours inspections; half-hour minimum for other listed items).
$49.31/hour for after-hours inspections, re-inspections, or additional plan review beyond the base submittal (per the same WSFM Rules Chapter 2 fee schedule)

Green River building permits

Get alerts for Green River

We'll email you when Green River's fees, documents, or codes change — not often.

We only use your email to send permit updates. No spam, unsubscribe anytime. Privacy.