Fire Sprinkler / Fire Alarm / Fire Suppression System Permit (State Plan Review + County Fire Authority) — Unincorporated Uinta County, Wyoming · Requirements sheet
Reviewed 2026-07-22 · Source: https://wsfm.wyo.gov/fire-prevention/plan-review
PermitBase is an independent reference and is not affiliated with any government agency. Requirements change and vary by project — confirm current details with the building department before you submit.
Fire Sprinkler / Fire Alarm / Fire Suppression System Permit (State Plan Review + County Fire Authority) in Unincorporated Uinta County, Wyoming
Unincorporated Uinta County has no standalone county-issued sprinkler/alarm permit application or published local fee schedule. Installation, addition, or alteration of ANY fire protection system (fire alarm, fire sprinkler, or fire suppression) requires a mandatory Wyoming State Fire Marshal's Office (Dept. of Fire Prevention & Electrical Safety) Plan Review 'regardless of size or valuation,' submitted through the WSFM eLicensing/ePermit/ePayment Portal — no work may begin before the state's Permit to Construct is issued. Locally, fire-code enforcement authority for Uinta County (including the unincorporated county) is held by the Uinta County Fire Protection & EMS Joint Powers Board — the countywide fire authority with a fire chief in Evanston and one in Bridger Valley — which Uinta County Resolution 24-44 (Nov 2024) empowers by adopting the 2024 ICC fire code text under the county's DELEGATED fire-prevention authority (W.S. § 35-9-121, 'Council for Fire Prevention,' the county acting as delegated authority of the State Fire Marshal/Director; see codesAdopted). No published local Joint Powers Board permit fee schedule, application form, or distinct local inspection process specific to fire sprinkler/alarm work was found on the county's official site despite an active search — this is a genuine documentation gap, not confirmation that no local review occurs. Confirm current local Fire District review/inspection requirements directly with the Fire District (Evanston 307-789-3013; Bridger Valley 307-783-1000) in addition to completing the mandatory state WSFM plan review.
Reviewed 2026-07-22 · Source
When you need this permit
- A Wyoming State Fire Marshal's Office Plan Review is mandatory for 'installation, addition, or alteration of fire protection systems (i.e. fire alarm, fire sprinkler, fire suppression) regardless of size or valuation' — this applies statewide, including unincorporated Uinta County
- Register on and submit through the WSFM eLicensing, ePermit, and ePayment Portal, using the applicable Plan Review Checklist for the system type
- Plans are accepted or rejected for review within 5 business days of receipt; a complete submittal is reviewed within 21 business days of acceptance (or 10 business days after receipt of any additional requested information, whichever is greater)
- No work may begin before the state's Permit to Construct is issued
- Review fees are calculated per the Department of Fire Prevention and Electrical Safety Rules, Chapter 2, Section 3 — no flat statewide dollar figure is published; the applicant is notified of the exact fee once plans are accepted
- Uinta County's own fire-code enforcement authority is delegated to and performed by the Uinta County Fire Protection & EMS Joint Powers Board under Resolution 24-44 (adopting the 2024 ICC fire code text under W.S. § 35-9-121 delegated fire-prevention authority) — confirm with the Fire District whether a separate local sign-off, inspection, or fee applies to a specific sprinkler/alarm project in addition to the mandatory state plan review, since no local fee schedule is published online
- This state plan-review requirement applies even though Uinta County has NOT taken general building-permit delegation (there is no county building permit for the surrounding construction — see land-use-certificate) — fire protection systems are reviewed under a separate, independent statutory trigger regardless of that fact
Required documents
Check off what you have — your progress is saved on this device.
Not ready yet — 0 of 1 required documents checked.
This checker covers one permit. A full project usually triggers several — our paid checklist will assemble all of them, from $29 →
Fee schedule
Review timeline
Inspection process
- 1
Fire Protection System Inspection (State)
Performed by or on behalf of the Wyoming State Fire Marshal's Office once the Permit to Construct is issued, per the standard WSFM plan-review process for fire alarm/sprinkler/suppression systems
- 2
Local Fire Authority Inspection (Uinta County Fire Protection & EMS Joint Powers Board) — unconfirmed
The Joint Powers Board holds delegated local fire-code enforcement authority for the county under Resolution 24-44; whether it separately inspects sprinkler/alarm installations beyond the state review was not confirmed in this chase — contact the Fire District directly
See the full Unincorporated Uinta County inspection guide — scheduling & re-inspection fees →
Tips
- Uinta County has no general building permit, but fire alarm/sprinkler/suppression work is still subject to a MANDATORY state plan review regardless of size or valuation — don't assume the lack of a county building permit means fire protection systems are unregulated.
- The Uinta County Fire Protection & EMS Joint Powers Board (not a city fire department) is the designated local fire authority for the whole county, including this unincorporated area — the same arrangement documented for the Town of Evanston, which has no fire department of its own.
- No local Joint Powers Board fee schedule or application for sprinkler/alarm permits is published online — call the Fire District (307-789-3013 Evanston / 307-783-1000 Bridger Valley) before assuming the state review is the only step required.
Frequently asked questions
Sources & verification
Key facts verified against official sources. Last reviewed 2026-07-22.
Fees, timelines, and adopted codes are researched from each jurisdiction's published records — see how we verify. Requirements change and vary by project, so always confirm the current details with the Unincorporated Uinta County building department before you submit. PermitBase is an independent reference and is not affiliated with any government agency.
Other permits in Unincorporated Uinta County
Fire Sprinkler / Fire Alarm / Fire Suppression System Permit (State Plan Review + County Fire Authority) in other cities
Look up this fee in a different city →
Now live
Build your Unincorporated Uinta County project checklist
Describe your project once and get every permit, document, and fee it triggers in Unincorporated Uinta County — in one checklist. Sign up and pay once to generate it, or go unlimited with Pro.
Get started →