Skip to main content
PermitBase

Coolidge building inspections

Verified

Inspection sequence, scheduling, and re-inspection fees for building permits in Coolidge, Arizona.

Verified 2026-07-06 · Source

How to schedule

Inspections are requested through the building department below.

Address
131 W. Pinkley Avenue, Coolidge, AZ 85128
Phone
520-723-6075
Office hours
Monday - Friday, 8 a.m. - 5 p.m. Inspection requests are handled via a separate Inspection Line (520-723-6049); inspections take place the next business day if the Inspection Request Form is received by 3:30 p.m. the prior business day (no inspections on holidays/weekends). Building Official: Bill Jones (wjones@coolidgeaz.com). FAX 520-723-6079, TDD 520-723-4653.

Inspection sequence

Applies to: Residential Building Permit (New Construction)

  1. 1

    Foundation/Footing

    Before concrete pour; verifies 18-inch minimum foundation depth and 10-inch minimum spread footing thickness per City of Coolidge amendments

  2. 2

    Framing

    Structural framing, connections, and egress per 2018 IRC and City of Coolidge amendments (metal framing anchors, floor-to-floor strap ties, truss-to-top-plate connections)

  3. 3

    Building Weather-Tight (Frame Inspection)

    Building must be weather-tight at the time of the frame inspection per Coolidge amendment to §110.304

  4. 4

    Final / Certificate of Occupancy

    All work complete per approved plans; building address numbers (4-inch minimum, durable material) must be displayed prior to final inspection/CO issuance

Applies to: Residential Addition / Remodel Permit

  1. 1

    Foundation/Footing

    Required before concrete pour; addition foundations must be tied to the existing foundation per City amendment

  2. 2

    Framing

    Structural connections to the existing structure

  3. 3

    Final

    Completed work verified against approved plans

Applies to: Sign Permit

  1. 1

    Footing

    Required for all detached (freestanding/monument/pole-style) signs, including when square footage or panels are added to an existing detached sign (Zoning Code §1108.E.13.a)

  2. 2

    Electrical

    Required on all signs prior to placement if the sign is electrically illuminated (Zoning Code §1108.E.13.b)

  3. 3

    Final

    Covers sign location, structural members, and placement of the insignia/copy against the approved permit (Zoning Code §1108.E.13.c)

Applies to: Swimming Pool / Spa Permit

  1. 1

    Pre-Gunite/Excavation

    Steel and plumbing rough-in verified before concrete shell placement

  2. 2

    Electrical Bonding

    Equipotential bonding grid and underwater lighting circuits verified before backfill/deck pour

  3. 3

    Final

    Pool barrier/fence (if applicable), equipment pad, and completed pool verified against approved plans and the 2018 ISPSC

Applies to: Electric Vehicle Charging Station Permit

  1. 1

    Rough-In

    New circuit wiring/conduit inspected before concealment

  2. 2

    Final

    Charger outlet or hardwired unit installed and connected, inspected before energizing

Applies to: Electrical Permit

  1. 1

    Rough-In

    Conduit, semi-rigid piping, or wiring inspected after installation but before concealment

  2. 2

    Final

    All conduit, wires, fixtures, and equipment (including covers) installed and connected, inspected before energizing

Applies to: Fence and Wall Permit

  1. 1

    Footing

    Required for block/masonry walls before backfill

  2. 2

    Final

    Completed fence/wall verified against approved plans, including pool barrier compliance where applicable

Applies to: Mechanical / HVAC Permit

  1. 1

    Rough-In

    Ductwork and equipment placement inspected before walls are closed

  2. 2

    Final

    Equipment operational; clearances and combustion air verified

Applies to: Plumbing Permit

  1. 1

    Underground/Rough-In

    Sewer, drainage, vent, water, and gas distribution systems inspected before burial or concealment

  2. 2

    Final

    All fixtures set and operating (or ready to operate pending utility connection); tests performed per building official and adopted plumbing code

Applies to: Residential Solar Photovoltaic (PV) Permit

  1. 1

    Rough Electrical

    Conduit runs, wire sizing, and disconnect placement inspected before energizing

  2. 2

    Final

    Panel mounting, racking attachment, roof penetration sealing, electrical connections, and interconnection point verified

Re-inspection fees

Residential Building Permit (New Construction)Re-inspection Fee · City of Coolidge Building Permit Fee Schedule, Article 3, Other Inspections and Fees item 2
$47.00

Coolidge building permits