Skip to main content
PermitBase

Solar Panel (Rooftop Photovoltaic) Permit in Victor, Colorado

Required for solar panel installations in Victor. Per the Permit Requirement Quick Guide, solar panel installations require a fuller plan set than most exterior remodel scopes, including engineering and drawing plans and electrical plans.

Verified 2026-07-06 · Source

When you need this permit

  • Permit, application, engineering plans, and drawing plans required per the Permit Requirement Quick Guide's Solar Panels line item
  • Electrical plans required for the interconnection/wiring portion of the installation
  • Electrical work governed by the 2014 NEC as adopted by the City
  • City Building Inspectors perform contemporaneous on-site license verification for any electrical contractor performing the interconnection work

Required documents

Check off what you have — your progress is saved on this device.

Not ready yet0 of 3 required documents checked.

This checker covers one permit. A full project usually triggers several — our paid checklist will assemble all of them, from $29

Fee schedule

Building Permit Fee (valuation-based, general schedule)No separate flat solar fee is published for the structural/building portion
$23.50 minimum, scaling per the valuation tiers in the City's Fee & Fine Schedule
Electric Permit Fee, Nonresidential/Alteration/Addition schedule (valuation-based)Applies to the electrical interconnection portion of a solar installation, per the general 'Nonresidential Buildings and Residential Alteration or Addition' Electric Permit fee table — the Fee & Fine Schedule does not name solar as its own line item
$115.00 for valuation $0-$2,000, plus $11.50 per $1,000 above that

Review timeline

Plan review
Not published — contact the department

How long did your Solar Panel (Rooftop Photovoltaic) Permit permit actually take in Victor?

Anonymous — one question, no email. Answers are combined and only shown once at least 5 people have reported.

Inspection process

  1. 1

    Rough Electrical

    Conduit runs, wire sizing, and disconnect placement before cover

  2. 2

    Final Inspection

    Racking, roof penetrations, and electrical connections verified

See the full Victor inspection guide — scheduling & re-inspection fees →

Tips

  • Solar installations in Victor require a fuller plan package (engineering, drawing, and electrical plans) than most other exterior remodel scopes on the Quick Guide — budget for a complete plan set rather than a simplified submittal.
  • The Fee & Fine Schedule does not name a solar-specific fee line; the electrical interconnection is billed under the general Nonresidential/Alteration Electric Permit valuation schedule.

Frequently asked questions

Victor requires a solar panel (rooftop photovoltaic) permit for: Permit, application, engineering plans, and drawing plans required per the Permit Requirement Quick Guide's Solar Panels line item; Electrical plans required for the interconnection/wiring portion of the installation; Electrical work governed by the 2014 NEC as adopted by the City; City Building Inspectors perform contemporaneous on-site license verification for any electrical contractor performing the interconnection work. If your project isn't listed, confirm with City of Victor Building Department at 719-689-2284 before starting work.

In Victor, the published Building Permit Fee (valuation-based, general schedule) is: $23.50 minimum, scaling per the valuation tiers in the City's Fee & Fine Schedule. Additional published fees: Electric Permit Fee, Nonresidential/Alteration/Addition schedule (valuation-based) — $115.00 for valuation $0-$2,000, plus $11.50 per $1,000 above that. These are the jurisdiction's own published figures — see the fee schedule table and source citations on this page.

Victor does not publish a plan-review timeline for this permit. Contact City of Victor Building Department at 719-689-2284 for current turnaround.

You'll need: Building Permit Application (Solar scope); Engineering and Drawing Plans; Electrical Plans. See the required-documents checklist on this page for details on each.

Victor requires 2 inspection(s) for a solar panel (rooftop photovoltaic) permit, in order: Rough Electrical, Final Inspection. Schedule each through City of Victor Building Department (719-689-2284).

Apply through City of Victor Building Department at 500 Victor Ave (also published as 500 W. Victor Ave.), PO Box 86, Victor, CO 80860. Phone: 719-689-2284. Office hours: Monday - Thursday: 8am to 5pm, Friday: 8am to Noon. The City contracts with Shums Coda Associates (ShumsCoda) as its Building Official for plan review and inspections; general/code-interpretation questions are directed to the Building Department main line above.. Official information: https://www.cityofvictor.com/building-department.

Victor, Colorado has adopted: 2012 International Building Code (IBC) — City of Victor Design Criteria document (Building Department page, 'Adopted Codes' section); 2012 International Residential Code (IRC); 2012 International Plumbing Code (IPC); 2012 International Mechanical Code (IMC); 2012 International Fuel Gas Code (IFGC); 2012 International Energy Conservation Code (IECC); 2014 National Electrical Code (NEC); Local amendments to the above codes are adopted by Ordinance No. 485; the Design Criteria document's direct link to the Ordinance No. 485 PDF (hosted on the City's legacy cityofvictor.com/downloads path) returned a connection error on re-check and could not be independently re-verified as still live — the amendment's EXISTENCE and code-cycle citation is confirmed via the current Design Criteria document itself (a live, actively-published Building Department resource), but its full text could not be retrieved during this pass.; Colorado Wildfire Resiliency Code: Ordinance No. 526 (adopted 3/19/2026) amends Chapter 18 of the Victor Municipal Code by adding a new Article 12 adopting the Colorado Wildfire Resiliency Code with local amendments — confirmed via the Municode Library's 'Adopted Ordinances Not Yet Codified' index for Victor, CO (ordinance not yet folded into the codified Chapter 18 text, which remains current only through Ordinance No. 511/2019 in the online codified view). This aligns with SB23-166's statewide Wildfire Resiliency Code Board mandate requiring local governments in the Wildland-Urban Interface to adopt minimum wildfire-resiliency structure-hardening and defensible-space standards by April 1, 2026.; The Design Criteria document (undated on-page, but the only live current-codes statement the Building Department publishes) is treated as the governing adopted-code list; it does not reference the 2024 code cycle used by some other Colorado jurisdictions in this corpus (e.g. Vail) — Victor's own document names 2012 I-Codes and 2014 NEC specifically, and no newer supersession was found on the Building Department, Building Permits, Ordinances and Resolutions, or Forms pages during this review.. Local amendments apply — see the Victor overview page for the full list.

Yes. The Permit Requirement Quick Guide lists a permit, application, engineering plans, drawing plans, and electrical plans for Solar Panel installations — a fuller package than most other exterior remodel categories.

Sources & verification

Verified against official sources. Last reviewed 2026-07-06.

Fees, timelines, and adopted codes are researched from each jurisdiction's published records — see how we verify. Requirements change and vary by project, so always confirm the current details with the Victor building department before you submit. PermitBase is an independent reference and is not affiliated with any government agency.