Sheridan building inspections
VerifiedInspection sequence, scheduling, and re-inspection fees for building permits in Sheridan, Wyoming.
Verified 2026-07-13 · Source
How to schedule
Inspections are requested through the building department below.
- Address
- 55 Grinnell Plaza, Sheridan, WY 82801
- Phone
- (307) 674-5941
- Office hours
- Mon–Fri 7:00 a.m.–4:00 p.m.
- Website
- Official site
Inspection sequence
Applies to: Accessory Dwelling Unit (ADU) Permit
- 1
Foundation / Footings
Before concrete pour, below the 42-inch local frost line
- 2
Framing
After framing complete, before insulation or wall cover
- 3
MEP Rough-In
Mechanical, electrical, plumbing rough-in before walls closed
- 4
Final
All work complete, ready for occupancy
Applies to: Change of Occupancy Use Permit (Certificate of Occupancy)
- 1
Fire Safety
Verifies fire-safety compliance of the location prior to occupancy (City Code Section 7-24.1(b))
- 2
Building Structure
Verifies structural/building-code compliance of the location prior to occupancy (City Code Section 7-24.1(b))
- 3
Sanitation
Verifies sanitation compliance of the location prior to occupancy (City Code Section 7-24.1(b))
- 4
Zoning
Verifies the intended use complies with the applicable zoning district prior to occupancy (City Code Section 7-24.1(b))
Applies to: Commercial Tenant Improvement Permit
- 1
Framing / Structural
After framing complete before walls covered
- 2
MEP Rough-In
Mechanical, electrical, plumbing rough-in before walls closed
- 3
Fire / Knox Box
Knox box installation verification (required on all commercial occupancies per local amendment); fire sprinkler/alarm inspections currently routed through the State per City's posted notice
- 4
Final / Certificate of Occupancy
All work complete, ready for occupancy
Applies to: Residential Addition / Remodel Permit
- 1
Footing / Foundation (if new footings)
Before concrete pour, below the 42-inch local frost line
- 2
Framing
After framing complete, before insulation or wall cover
- 3
MEP Rough-In
Electrical, plumbing, mechanical rough-in before walls closed
- 4
Final
All work complete per approved plans
Applies to: Residential Building Permit (New Construction)
- 1
Foundation / Footings
Before concrete pour — footings must extend below the 42-inch local frost line
- 2
Framing
After framing complete, before insulation or wall cover
- 3
MEP Rough-In
Mechanical, electrical, and plumbing rough-in before walls closed
- 4
Final
All work complete, smoke/CO detectors installed, ready for occupancy
Applies to: Deck Permit
- 1
Footing
Pier/footing depth verification below 42-inch frost line, before concrete pour
- 2
Framing
Ledger attachment, joist hangers, structural connections before decking installed
- 3
Final
Guardrails, stairs, and decking complete per approved plans
Applies to: Mechanical / HVAC Permit
- 1
Gas Piping Pressure Test
Required before concealing gas piping — 10 lbs held for 15 minutes on threaded gas piping per local IFGC amendment
- 2
Rough-In / Equipment
Equipment installation and ductwork before walls closed
- 3
Final
Equipment operational, combustion air and venting verified
Applies to: Plumbing Permit
- 1
Underground / Under-slab
Before concrete pour — verify pipe slope, materials, cleanouts
- 2
Rough-In
After pipes installed, before walls closed — includes 5 psi/15-minute air test per local IPC amendment
- 3
Final
All fixtures connected, no leaks, venting verified
Applies to: Electrical Permit
- 1
Rough-In
Wiring and conduit installed before walls closed
- 2
Final
All devices installed, panel labeled, system energized
Applies to: EV Charger / EVSE Permit (Electrical Simple Permit)
- 1
Rough-In
Circuit wiring, conduit, and panel connections before walls are closed, if applicable
- 2
Final
Charger mounted, connections verified, system energized
Applies to: Fire Sprinkler / Fire Alarm / Fire Suppression System Permit
- 1
System Rough-In
Piping, wiring, and device placement before concealment, per approved plans
- 2
Final / Acceptance Test
Functional/acceptance testing of the completed fire alarm, sprinkler, or suppression system per the approved plans and adopted Fire Code
Applies to: Solar PV Permit
- 1
Rough Electrical
Conduit runs, wire sizing, disconnect placement before cover
- 2
Final
All connections and racking/roof penetrations verified, system energized
Final inspection only: Demolition Permit, Roofing Permit (Re-Roof), Sign Permit
Re-inspection fees
Sources & verification
Verified against official sources. Last reviewed 2026-07-13.
Fees, timelines, and adopted codes are researched from each jurisdiction's published records — see how we verify. Requirements change and vary by project, so always confirm the current details with the Sheridan building department before you submit. PermitBase is an independent reference and is not affiliated with any government agency.
Sheridan building permits
Get alerts for Sheridan
We'll email you when Sheridan's fees, documents, or codes change — not often.