Parker building inspections
VerifiedInspection sequence, scheduling, and re-inspection fees for building permits in Parker, Colorado.
Verified 2026-07-05 · Source
How to schedule
Inspections are requested through the building department below.
- Address
- 20120 E. Mainstreet, Parker, CO 80138
- Phone
- 303-841-1970
- Office hours
- Monday-Friday, 8 a.m.-5 p.m. Inspection requests called in prior to 4 p.m. are performed the following business day; roofing inspections occur 8 a.m.-12 p.m., no same-day requests.
- Website
- Official site
Published scheduling rules
- No same-day inspection requests are accepted; requests go through the eTrakit account. (Re-Roofing Permit)
Inspection sequence
Applies to: Residential Addition / Remodel / Alteration Permit
- 1
Footing/Foundation
Required before concrete pour for additions, deck posts, or garage foundations
- 2
Framing
Structural framing and connections to the existing structure
- 3
MEP Rough-In
Electrical, plumbing, mechanical rough-in as applicable before walls closed
- 4
Final
All work complete per approved plans
Applies to: Residential Building Permit (New Construction)
- 1
Foundation/Footing
Before concrete pour
- 2
Framing
Structural framing per approved plans
- 3
MEP Rough-In
Mechanical, electrical, plumbing rough-in, including HVAC duct-leakage and static-pressure testing per the Town's Residential HVAC Design & Testing Requirements
- 4
Final
All work complete per approved plans; HVAC trade contractor certification required at final that the system has been cleaned and is in proper working order
Applies to: Electrical Permit
- 1
Rough-In
Wiring and conduit installed before walls closed
- 2
Final
Devices installed, panel labeled, system energized
Applies to: EV Charger / EVSE Permit
- 1
Rough-In
Circuit wiring and conduit installed before walls closed
- 2
Final
EVSE installed, devices verified, system energized
Applies to: Mechanical / HVAC Permit
- 1
Rough-In / Duct Testing
Equipment/ductwork installation before concealment; for new construction, duct-leakage test at rough (max 4 CFM per 100 sq ft of conditioned area at 0.1 in. w.g.) per the Town's HVAC testing requirements
- 2
Final
Equipment operational; for new construction, final duct-leakage/static-pressure/airflow testing and an HVAC contractor certification that the system has been cleaned and is in proper working order
Applies to: Plumbing Permit
- 1
Underground/Rough-In
Before concealment — pipe slope, materials, cleanouts
- 2
Final
Fixtures connected, no leaks, proper venting verified
Applies to: Re-Roofing Permit
- 1
Mid-Roof
Required only for solar shingles, tile, slate, stone-coated steel, EPDM, flat roofs, and similar reroofs — no more than 25-50% of the roof may be complete prior to this inspection. NOT required for standard residential asphalt shingle reroofs.
- 2
Final
Required for all roof permit applications; residential asphalt shingle applications only need to schedule this Final Inspection
Applies to: Solar Photovoltaic (PV) Permit
- 1
Rough Electrical / Rough Frame
Conduit runs, wire sizing, disconnect placement, and any structural/racking framing — scheduled the same day as the other Solar PV inspections
- 2
Final Electrical / Final Building and Electrical Service
Panel mounting, racking attachment, all electrical connections verified; solar rapid-shutdown test performed at this time; inspector requires attic access and the signed Rooftop Installation Affidavit on site
Re-inspection fees
Sources & verification
Verified against official sources. Last reviewed 2026-07-05.
Fees, timelines, and adopted codes are researched from each jurisdiction's published records — see how we verify. Requirements change and vary by project, so always confirm the current details with the Parker building department before you submit. PermitBase is an independent reference and is not affiliated with any government agency.
Parker building permits
Get alerts for Parker
We'll email you when Parker's fees, documents, or codes change — not often.
We only use your email to send permit updates. No spam, unsubscribe anytime. Privacy.