Roofing Permit (Re-Roof) in Sterling, Colorado

Required for reroofing work on structures in Sterling, using a dedicated Re-Roof Permit Application. Governed by the 2018 IRC/IBC as locally adopted, with detailed local rules requiring complete tearoff (no overlays), ice barrier, flashing, ventilation, and a mandatory pre-mid-roof inspection in addition to the final inspection.

Verified 2026-07-06 · Source

When you need this permit

  • Permit required for reroofing, per the Permits and Licenses page ('reroofing' is listed among permit-required work)
  • Only ONE layer of asphalt shingles allowed (2018 IRC § R907.3(4) / § R903.5) — NO OVERLAYS; complete tearoff to the exposed deck is required, with no felt or underlayment permitted to remain
  • Ice barrier required in areas with a history of ice-damming (Table R301.2(1)), per § R905.1.2: two cemented underlayment layers or a self-adhering polymer-modified bitumen sheet, extending from the lowest roof edge to at least 24 inches inside the exterior wall line (36 inches on slopes 8:12 or greater), except detached accessory structures without conditioned floor area
  • Flashings required per § R905.2.8 / § R905.3.8 / § R905.4.6 / § R905.6.6 / § R905.8.8 or manufacturer's installation instructions, depending on roofing material
  • Roof/attic ventilation required per § R806.1-R806.2 (net free ventilating area not less than 1/150 of the ventilated space, or 1/300 if 50-80% of vents are in the upper portion at least 3 ft above eave/cornice vents)
  • Asphalt shingles must meet ASTM D7158 (Class G or H) for wind resistance
  • Sheathing must be solid per 2018 IRC § R905.2.1 — asphalt shingles must be fastened to solidly sheathed decks
  • An IN-PERSON pre-mid-roof inspection is required in addition to the final roof inspection — 'No final roofs will be completed without a pre-mid inspection'

Required documents

Check off what you have — your progress is saved on this device.

Not ready yet0 of 1 required documents checked.

This checker covers one permit. A full project usually triggers several — our paid checklist will assemble all of them, from $29

Fee schedule

Building Permit Fee (same valuation-based table)Reroof applications use the same Plan Review Fee / Building Permit Fee / Use Tax fields as the standard Building Permit Application
$23.50 minimum, scaling per the Resolution No. 11-1-24 valuation tiers
City Use Tax
4% of material cost (or 4% of at least one-half of total permit valuation if material cost is not separately listed)

Review timeline

Plan review
Not published — contact the department

How long did your Roofing Permit (Re-Roof) permit actually take in Sterling?

Anonymous — one question, no email. Answers are combined and only shown once at least 5 people have reported.

Inspection process

  1. 1

    Pre-Mid-Roof Inspection

    Mandatory in-person inspection required before the roof can be completed; 'No final roofs will be completed without a pre-mid inspection'

  2. 2

    Final Roof Inspection

    Completed roof — tearoff, ice barrier, flashing, ventilation, and fastening compliance verified per 2018 IRC as locally amended

See the full Sterling inspection guide — scheduling & re-inspection fees →

Tips

  • Sterling requires FULL tearoff on every reroof — no overlay layers are permitted at all, regardless of existing layer count, and no felt/underlayment may be left on the deck.
  • Don't skip the pre-mid-roof inspection: the City will not complete/approve a final roof without it having occurred first, per the City's own roofing bulletin.
  • Ice barrier is required in areas with a history of ice damming per the state climatic table (Table R301.2(1)) — confirm whether your specific roof area needs it based on slope and location before installing underlayment.

Frequently asked questions

Sterling requires a roofing permit (re-roof) for: Permit required for reroofing, per the Permits and Licenses page ('reroofing' is listed among permit-required work); Only ONE layer of asphalt shingles allowed (2018 IRC § R907.3(4) / § R903.5) — NO OVERLAYS; complete tearoff to the exposed deck is required, with no felt or underlayment permitted to remain; Ice barrier required in areas with a history of ice-damming (Table R301.2(1)), per § R905.1.2: two cemented underlayment layers or a self-adhering polymer-modified bitumen sheet, extending from the lowest roof edge to at least 24 inches inside the exterior wall line (36 inches on slopes 8:12 or greater), except detached accessory structures without conditioned floor area; Flashings required per § R905.2.8 / § R905.3.8 / § R905.4.6 / § R905.6.6 / § R905.8.8 or manufacturer's installation instructions, depending on roofing material; Roof/attic ventilation required per § R806.1-R806.2 (net free ventilating area not less than 1/150 of the ventilated space, or 1/300 if 50-80% of vents are in the upper portion at least 3 ft above eave/cornice vents); Asphalt shingles must meet ASTM D7158 (Class G or H) for wind resistance; Sheathing must be solid per 2018 IRC § R905.2.1 — asphalt shingles must be fastened to solidly sheathed decks; An IN-PERSON pre-mid-roof inspection is required in addition to the final roof inspection — 'No final roofs will be completed without a pre-mid inspection'. If your project isn't listed, confirm with City of Sterling Public Works Department, Code Enforcement Division at (970) 522-9700, ext. 1109 (Marianne, permits and licenses); main line (970) 522-9700; fax (970) 521-0632 before starting work.

In Sterling, the published Building Permit Fee (same valuation-based table) is: $23.50 minimum, scaling per the Resolution No. 11-1-24 valuation tiers. Additional published fees: City Use Tax — 4% of material cost (or 4% of at least one-half of total permit valuation if material cost is not separately listed). These are the jurisdiction's own published figures — see the fee schedule table and source citations on this page.

Sterling does not publish a plan-review timeline for this permit. Contact City of Sterling Public Works Department, Code Enforcement Division at (970) 522-9700, ext. 1109 (Marianne, permits and licenses); main line (970) 522-9700; fax (970) 521-0632 for current turnaround.

You'll need: Re-Roof Permit Application. See the required-documents checklist on this page for details on each.

Yes. The City requires an in-person pre-mid-roof inspection in addition to the final roof inspection, and states that no final roof will be completed without the pre-mid inspection having occurred.

Apply through City of Sterling Public Works Department, Code Enforcement Division at 421 N. 4th Street, P.O. Box 4000, Sterling, CO 80751. Phone: (970) 522-9700, ext. 1109 (Marianne, permits and licenses); main line (970) 522-9700; fax (970) 521-0632, email: harbart@sterlingcolo.com (permits and licenses); pubworks@sterlingcolo.com (general Public Works). Office hours: Not published on the Permits and Licenses page as of this review; inspection requests are scheduled by phone at (970) 522-9700, with a stated same-day/next-day cutoff (see reviewTimelineNote on inspections below).. Official information: https://www.sterlingcolo.com/departments/public_works/permits_and_licenses.php.

Sterling, Colorado has adopted: 2018 International Building Code (IBC), with Appendices A, E, and I — City of Sterling Municipal Code § 5-31, adopted by Ord. No. 5-2023 (eff. 6/13/23); a copy is kept at the City Clerk's office for public inspection; 2018 International Residential Code (IRC), with Appendices F and H — Municipal Code § 5-56, adopted by Ord. No. 7-2023 (eff. 6/13/23); IRC Section R313 (Automatic Fire Sprinkler Systems) is expressly omitted in its entirety; 2018 International Mechanical Code (IMC) — Municipal Code § 5-43, adopted by Ord. No. 6-2023 (eff. 6/13/23); 2018 International Energy Conservation Code (IECC) — Municipal Code § 5-106, adopted by Ord. No. 8-2023 (eff. 6/13/23); 2018 International Fuel Gas Code (IFGC) — Municipal Code § 5-140, adopted by Ord. No. 9-2023 (eff. 6/13/23); 2018 International Existing Building Code (IEBC), with Appendices B and C, adopted in its entirety without amendment per state law — Municipal Code § 5-150, adopted by Ord. No. 10-2023 (eff. 6/13/23); Uniform Code for the Abatement of Dangerous Buildings, 1994 Edition (ICBO) — Municipal Code § 5-16, as amended by Ord. Nos. 12-1992, 26-1995, and 2-2009; Any references to plumbing or electrical requirements (except required-fixture references) are explicitly EXCEPTED from both the IBC and IRC as locally adopted — Municipal Code § 5-31(b) and § 5-56(b) — because plumbing and electrical permitting/inspection in Sterling is handled by the State of Colorado, not the City; Manufactured/mobile home installations follow C.R.S. § 24-32-3101 et seq. rather than a City-adopted installation code — Municipal Code § 5-121. Local amendments apply — see the Sterling overview page for the full list.

No. The City's roofing rules require complete tearoff to the exposed deck for every reroof — only one layer of asphalt shingles is ever allowed, and no felt or underlayment may remain on the roof.

Sources & verification

Verified against official sources. Last reviewed 2026-07-06.

Fees, timelines, and adopted codes are researched from each jurisdiction's published records — see how we verify. Requirements change and vary by project, so always confirm the current details with the Sterling building department before you submit. PermitBase is an independent reference and is not affiliated with any government agency.