Skip to main content
PermitBase

Taylorsville building inspections

Verified

Inspection sequence, scheduling, and re-inspection fees for building permits in Taylorsville, Utah.

Verified 2026-06-30 · Source

How to schedule

Inspections are requested through the building department below.

Address
2600 Taylorsville Blvd., Taylorsville, UT 84129
Phone
(801) 955-2030
Office hours
Mon–Fri 8:00 a.m. – 5:00 p.m.; Inspections 9:00 a.m. – 4:00 p.m.

Inspection sequence

Applies to: Residential Building Permit

  1. 1

    Foundation / Footing

    Before concrete pour — forms, rebar, anchor bolts

  2. 2

    Framing

    After framing, sheathing, and roof — before insulation or wall cover

  3. 3

    Insulation

    After insulation installed, before drywall

  4. 4

    Final

    All work complete, ready for certificate of occupancy

Applies to: Commercial Building Permit

  1. 1

    Foundation / Footing

    Before concrete pour, per standard IBC inspection sequence.

  2. 2

    Framing

    After framing, sheathing, and roof installed.

  3. 3

    Final

    All work complete before occupancy.

Applies to: Change of Use Permit

  1. 1

    Unified Fire Authority Inspection

    Onsite inspection required for all commercial businesses, verifying exit signage, unblocked exit corridors, approved fire extinguishers, and functioning fire suppression sprinklers, before business license issuance.

  2. 2

    Building Division Final / Certificate of Occupancy Inspection

    Required only if tenant improvements were performed for the new use — confirms the completed work complies with the approved building permit before occupancy begins.

Applies to: Commercial Tenant Improvement / Tenant Finish Permit

  1. 1

    Framing / Structural

    Where applicable to the tenant-improvement scope, before close-in.

  2. 2

    Final

    All work complete before occupancy.

Applies to: Demolition Permit

  1. 1

    Pre-Demolition

    Verify utility disconnects are complete and any required asbestos/DAQ clearance is obtained before work begins

  2. 2

    Final / Site Clear

    Site cleared, foundation removed or capped, site conditions verified

Applies to: Electrical Service Permit

  1. 1

    Service / Panel

    Panel installation, grounding electrode system, service entrance conductors

  2. 2

    Final

    All devices installed, GFCI/AFCI protection verified, panel labeled

Applies to: EV Charger / EVSE Permit

  1. 1

    Service / Panel

    Panel/circuit installation and grounding electrode system inspection for the EVSE circuit.

  2. 2

    Final

    Charger mounted and energized, GFCI/breaker protection verified.

Applies to: Fire Sprinkler & Fire Alarm Permit

  1. 1

    Rough-In / Underground

    Underground supply piping and rough sprinkler or alarm wiring inspected before concealment; Material and Test Certificates required for aboveground/underground piping.

  2. 2

    Final Acceptance Test

    Full system functional/acceptance test witnessed by UFA; Record of Completion form executed for fire alarm systems before the system is placed in service.

Applies to: Gas Line Permit

  1. 1

    Rough-In / Pressure Test

    Piping installed, pressure tested — no leaks before concealment

  2. 2

    Final

    Appliances connected, gas flowing, leak check complete, proper drip legs installed

Applies to: Mechanical / HVAC Permit

  1. 1

    Rough-In

    Ductwork installed, before walls closed — verify clearances and support

  2. 2

    Final

    Equipment operational, combustion air verified, gas pressure tested, thermostat functional

Applies to: Roofing Permit

  1. 1

    Deck / Substrate

    After tear-off — verify sheathing condition and replace damaged decking before proceeding

  2. 2

    Final

    Completed roof — verify ice and water shield, flashing, drip edge, and nailing pattern

Applies to: Sign Permit

  1. 1

    Final (permanent signs with electrical/footings/engineering)

    Confirms sign placement and construction conform to the permit application and applicable building/safety codes, per § 13.26.110(B)(1)

  2. 1

    Temporary sign tag verification

    Approved temporary signs receive a city-issued tag that must be displayed for the duration of the approved period; inspected for conformance with the approval, per § 13.26.110(B)(2)

Applies to: Solar Panel Permit

  1. 1

    Rough Electrical

    Conduit runs, wire sizing, disconnect placement before energizing

  2. 2

    Final / Structural

    Panel mounting, racking attachment, roof penetration sealing, and electrical connections verified

Sources & verification

Verified against official sources. Last reviewed 2026-06-30.

Fees, timelines, and adopted codes are researched from each jurisdiction's published records — see how we verify. Requirements change and vary by project, so always confirm the current details with the Taylorsville building department before you submit. PermitBase is an independent reference and is not affiliated with any government agency.

Taylorsville building permits

Get alerts for Taylorsville

We'll email you when Taylorsville's fees, documents, or codes change — not often.

We only use your email to send permit updates. No spam, unsubscribe anytime. Privacy.