Skip to main content
PermitBase

Solar Panel Permit in Taylorsville, Utah

Required for installation of rooftop or ground-mounted solar photovoltaic systems in Taylorsville. Per Taylorsville's official 'Solar P.V. Systems' submittal form (B-7), a P.V. array requires a standard Building Permit, and applicants must submit a valuation document (proposal/bid/contract) showing the value of the work — confirming the structural/PV installation is assessed the standard valuation-based building permit fee under the Taylorsville City Consolidated Fee Schedule. The electrical interconnection is a separate Electrical Service permit ($60 flat fee). No standalone solar/PV line item exists in the Consolidated Fee Schedule.

Verified 2026-07-01 · Source

When you need this permit

  • Rooftop solar panel installation
  • Ground-mounted solar array installation
  • Electrical service change or upgrade for solar interconnection (Electrical Service permit required)

Required documents

Check off what you have — your progress is saved on this device.

Not ready yet0 of 4 required documents checked.

This checker covers one permit. A full project usually triggers several — our paid checklist will assemble all of them, from $29

Fee schedule

Building Permit (structural/valuation-based)Grounded: Taylorsville 'Solar P.V. Systems' submittal form B-7 (Rev 7/9/20, taylorsvilleut.gov/home/showpublisheddocument/4610/637299084140100000) requires a standard Building Permit and a Valuation document (proposal/bid/contract) for the P.V. array; fee then applies per the Taylorsville City Consolidated Fee Schedule (Revised & Approved March 19, 2026) Valuation Based Building Permit Fees table. Confirmed by full-text search of the fee schedule: no standalone solar/PV line item exists — solar structural work is charged via the standard valuation-based building permit, which is a published, cited table (verified per grounding rule for valuation-based fees).
Valuation-based — see residential building permit fee schedule; valuation is based on the proposal/bid/contract value of the P.V. installation, per the required 'Valuation' submittal document
Electrical Service Charge — Flat Fee (for electrical interconnection)Taylorsville City Consolidated Fee Schedule, Revised & Approved March 19, 2026 — separate permit required for electrical service change or interconnection
$60.00

Review timeline

Plan reviewTypical estimate — confirm current times with the Taylorsville building department
~5–10 business days

How long did your Solar Panel Permit permit actually take in Taylorsville?

Anonymous — one question, no email. Answers are combined and only shown once at least 5 people have reported.

Inspection process

  1. 1

    Rough Electrical

    Conduit runs, wire sizing, disconnect placement before energizing

  2. 2

    Final / Structural

    Panel mounting, racking attachment, roof penetration sealing, and electrical connections verified

See the full Taylorsville inspection guide — scheduling & re-inspection fees →

Tips

  • Taylorsville publishes a 'Solar P.V. Systems' (B-7) information form — download it from the Information Forms page before applying; it requires a site plan, electrical one-line diagram, roof-load verification, and a valuation document (proposal/bid/contract).
  • Rocky Mountain Power interconnection approval is required before the system can be energized — obtain this in parallel with the city permit; final inspection triggers Net Meter authorization.
  • Confirm with Taylorsville Building Department at (801) 955-2030 whether your project requires combined or separate building and electrical permits.
  • Utah offers a state income tax credit for residential solar — check Utah Tax Commission publications for current incentive amounts.

Frequently asked questions

Yes. Taylorsville requires a standard Building Permit for solar P.V. installations, per the city's official 'Solar P.V. Systems' (B-7) submittal form, which requires a valuation document (proposal/bid/contract). The permit fee is assessed on that valuation using the Consolidated Fee Schedule's Valuation Based Building Permit Fees table (Revised & Approved March 19, 2026). The electrical interconnection requires a separate Electrical Service permit ($60 flat fee). Call (801) 955-2030 to confirm the current permitting path for your project.

In Taylorsville, the published Building Permit (structural/valuation-based) is: Valuation-based — see residential building permit fee schedule; valuation is based on the proposal/bid/contract value of the P.V. installation, per the required 'Valuation' submittal document. Additional published fees: Electrical Service Charge — Flat Fee (for electrical interconnection) — $60.00. These are the jurisdiction's own published figures — see the fee schedule table and source citations on this page.

Plan review for a solar panel permit in Taylorsville typically runs 5–10 business days. This is an estimate, not a published figure — confirm current review times with Taylorsville City Building Department at (801) 955-2030.

You'll need: Solar Site Plan / Roof Plan; Electrical Single-Line Diagram; Structural Analysis; Equipment Specifications. Depending on your project, Taylorsville may also ask for: Interconnection Agreement. See the required-documents checklist on this page for details on each.

Taylorsville requires 2 inspection(s) for a solar panel permit, in order: Rough Electrical, Final / Structural. Schedule each through Taylorsville City Building Department ((801) 955-2030).

Apply through Taylorsville City Building Department at 2600 Taylorsville Blvd., Taylorsville, UT 84129. Phone: (801) 955-2030, email: mcortez@taylorsvilleut.gov. Office hours: Mon–Fri 8:00 a.m. – 5:00 p.m.; Inspections 9:00 a.m. – 4:00 p.m.. Official information: https://www.taylorsvilleut.gov/government/building-department.

Taylorsville, Utah has adopted: 2024 International Building Code (IBC) — Utah Code § 15A-2-103(1)(a); CURRENT as of 7/1/2026. Confirmed live on the Taylorsville Building Department page (taylorsvilleut.gov/government/building-department, re-fetched 2026-07-16), which itself now states the current statewide code table verbatim: '2024 I.B.C., 2021 I.R.C., 2024 I.P.C., 2024 I.M.C., 2024 I.F.G.C., 2024 I.E.C.C., 2023 N.E.C.' Supersedes the 2021 IBC, which governed through 6/30/2026.; 2021 International Residential Code (IRC) — Utah Code § 15A-2-103(1)(b); UNCHANGED by the 7/1/2026 code cycle — confirmed both by the live statute and by Taylorsville's own building page (re-fetched 2026-07-16, listing '2021 I.R.C.').; 2024 International Plumbing Code (IPC) — Utah Code § 15A-2-103(1)(d); CURRENT as of 7/1/2026, confirmed live on the Taylorsville Building Department page (re-fetched 2026-07-16). Supersedes the 2021 IPC, which governed through 6/30/2026.; 2024 International Mechanical Code (IMC) — Utah Code § 15A-2-103(1)(e); CURRENT as of 7/1/2026, confirmed live on the Taylorsville Building Department page (re-fetched 2026-07-16). Supersedes the 2021 IMC, which governed through 6/30/2026.; 2024 International Fuel Gas Code (IFGC) — Utah Code § 15A-2-103(1)(f); CURRENT as of 7/1/2026, confirmed live on the Taylorsville Building Department page (re-fetched 2026-07-16). Supersedes the 2021 IFGC, which governed through 6/30/2026.; 2024 International Energy Conservation Code (IECC) — Utah Code § 15A-2-103(1)(h); CURRENT as of 7/1/2026, confirmed live on the Taylorsville Building Department page (re-fetched 2026-07-16). ONE statewide edition — the statute does not split residential/commercial IECC editions. Supersedes the 2021 IECC, which governed through 6/30/2026.; 2023 National Electrical Code (NEC) — Utah Code § 15A-2-103(1)(g); UNCHANGED by the 7/1/2026 code cycle statewide. CORRECTION (2026-07-20, supersedes the 2026-07-16 note below): the 07-16 edit claimed Taylorsville's page had been updated to 'correctly' list 2023 N.E.C. and that the prior 2020-NEC lag was resolved — that was wrong. The page genuinely contradicts itself and still does as of this re-check: a summary table near the top states the statewide-adopted codes verbatim ('2024 I.B.C., 2021 I.R.C., 2024 I.P.C., 2024 I.M.C., 2024 I.F.G.C., 2024 I.E.C.C., 2023 N.E.C.'), but the page's own FAQ section separately answers 'What codes and standards does the building department use?' with: 'Currently we are using the 2021 I-codes with 2017 A.N.S.I. 117.1 as the accessibility standard, and the 2020 National Electrical Code.' Confirmed via a 2026-07-08 Wayback snapshot (predating the 07-16 edit) already showing that exact FAQ text, and independently re-confirmed live 2026-07-20 — the page has not changed; the 07-16 edit simply picked one side of an internal contradiction and declared it resolved. Reported here as-is rather than guessing which statement the department actually enforces in practice.; NOTE (2026-07-20, supersedes the 2026-07-16 corpus-staleness note below): the IBC/IRC/IPC/IMC/IFGC/IECC lines above match the page's top summary table verbatim, independently re-confirmed 2026-07-20. But that table is not the whole story — see the NEC line's correction above for the page's separate, contradicting FAQ answer, which claims the department is 'currently using' the 2021 I-codes generally (not just for NEC). Treat every 'current as of 7/1/2026' framing above as citing the summary table specifically, not as a claim that Taylorsville's practice has been independently confirmed to match it. The International Fire Code (IFC) is not adopted anywhere in §15A-2-103 and is not listed on Taylorsville's page either — that part of the original 07-16 note still holds..

Sources & verification

Verified against official sources. Last reviewed 2026-07-01.

Fees, timelines, and adopted codes are researched from each jurisdiction's published records — see how we verify. Requirements change and vary by project, so always confirm the current details with the Taylorsville building department before you submit. PermitBase is an independent reference and is not affiliated with any government agency.