Skip to main content
PermitBase

Chandler building inspections

Verified

Inspection sequence, scheduling, and re-inspection fees for building permits in Chandler, Arizona.

Verified 2026-07-16 · Source

How to schedule

Inspections are requested through the building department below.

Address
215 E. Buffalo St., Chandler, AZ 85225
Phone
480-782-3000
Office hours
Monday – Friday 8:00 AM – 5:00 PM, except holidays; Walk-in plan review: Monday – Friday 8:00 AM – 4:30 PM

Published scheduling rules

  • Schedule inspections online at developmentpermits.chandleraz.gov/clics/ or by IVR at (480) 782-3100. (Commercial Fire Sprinkler / Fire Alarm System Permit)
  • Inspection scheduling options: online at developmentpermits.chandleraz.gov/clics/, by phone IVR at 480-782-3100 (prior to midnight for next-day inspection), or by text to 844-281-3520. (General)

Inspection sequence

Applies to: Residential Building Permit (New Home / Addition / Remodel)

  1. 1

    Footings

    All forms, reinforcing steel and UFER ground in place; schedule before concrete is poured. An additional inspection is required for stems poured separately.

  2. 2

    Monolithic footing

    Reinforcing steel, UFER, forms and accessories in place, but not covered.

  3. 3

    Plumbing (groundwork)

    Under-floor building drain installed, shaded and under pressure test, but not covered.

  4. 4

    Water piping and water service (groundwork)

    Under-floor water piping installed but not covered; water service yard piping installed and under pressure but not covered.

  5. 5

    Building sewers

    Sewer piping connecting the building to the private or public sewer is installed, shaded and properly supported, but not covered.

  6. 6

    Strap and shear

    All shear panels and mechanical fasteners installed, but not covered.

  7. 7

    Rough electrical, rough plumbing, rough HVAC, and framing (concurrent)

    Inspections 10–13 are typically done concurrently: all rough-in electrical installed (not covered); all rough-in plumbing installed and under pressure (not covered); all rough-in mechanical work installed (not covered); building is 'dried in' and all framing, gussets, shear panels, anchors and all trade rough-ins are in place (not covered).

  8. 8

    Wallboard

    Wallboard installed and nailed, but not filled or taped.

  9. 9

    Lath inspection (if applicable)

    All substrate wire mesh and trim installed, ready to receive stucco, but not covered.

  10. 10

    Final Inspection

    Building completed to the requirements of the approved plans, specifications, and the City of Chandler codes.

Applies to: Commercial Fire Sprinkler / Fire Alarm System Permit

  1. 1

    Fire Sprinkler Visual

    Visual inspection of installed fire sprinkler system components prior to cover, per the City of Chandler's published Building Inspection Codes (Fire Protection group, code 760).

  2. 2

    Fire Sprinkler OPT (200 psi hydrostatic test)

    Operational pressure test of the fire sprinkler system (Fire Protection group, code 761).

  3. 3

    Fire Sprinkler Alarm Test

    Test confirming the sprinkler system correctly activates the fire alarm (Fire Protection group, code 762).

  4. 4

    Fire Alarm System Visual

    Visual inspection of installed fire alarm system devices and wiring (Fire Protection group, code 763).

  5. 5

    Fire Alarm System Test

    Functional test of the fire alarm system (Fire Protection group, code 764).

  6. 6

    Fire Protection Final

    Final inspection confirming the fire sprinkler/alarm system is completed per approved plans and the 2024 IFC with Chandler amendments (Fire Protection group, code 770).

Applies to: Plumbing Permit

  1. 1

    Plumbing (groundwork)

    Under-floor building drain installed, shaded and under pressure test, but not covered.

  2. 2

    Water piping (groundwork)

    All under-floor water piping installed but not covered.

  3. 3

    Building sewers

    Sewer piping installed, shaded, and properly supported, but not covered.

  4. 4

    Upper-level drainage

    Tubs filled to flood rim (upper-level drainage test).

  5. 5

    Rough plumbing

    All rough-in plumbing installed and under pressure test, but not covered.

  6. 6

    Final inspection

    All plumbing work completed per approved plans and the 2024 IPC with Chandler amendments.

Applies to: Accessory Dwelling Unit (ADU) Permit

  1. 1

    Footings / foundation

    All forms, reinforcing steel and UFER ground in place before concrete is poured.

  2. 2

    Rough trades and framing (concurrent)

    Rough electrical, rough plumbing, rough HVAC, and framing inspected concurrently before cover.

  3. 3

    Wallboard

    Wallboard installed and nailed but not filled or taped.

  4. 4

    Final inspection

    ADU completed to requirements of approved plans and city codes.

Applies to: Electrical Permit

  1. 1

    Electric (groundwork)

    Conduit installed but not covered (for underground electrical runs).

  2. 2

    Rough electrical

    All rough-in electrical installed but not covered.

  3. 3

    Final inspection

    All electrical work completed to requirements of approved plans and 2023 NEC with Chandler amendments.

Applies to: Mechanical / HVAC Permit

  1. 1

    Rough heating and ventilation (groundwork)

    Ductwork installed but not covered (groundwork inspection).

  2. 2

    Rough heating and ventilation

    All rough-in mechanical work installed but not covered.

  3. 3

    Final inspection

    All mechanical/HVAC work completed per approved plans and 2024 IMC/IFGC with Chandler amendments.

Applies to: Residential Pool / Spa Permit

  1. 1

    Pre-gunite inspection

    First inspection; no one needs to be home. Plans and permit must be available on site. For custom in-ground pools: reinforcing steel, forms, and structural elements before gunite/shotcrete is applied.

  2. 2

    Pre-plaster inspection (barrier inspection)

    Second inspection; homeowner must be present if the house forms part of the interior barrier or there is no interior pool fence. If an interior fence encompasses the entire pool, homeowner presence is not required. All electrical service panels must be left unlocked for the inspector. Inspections requiring entry into the home will not be conducted unless a responsible adult is present.

  3. 3

    Final inspection

    All pool/spa work completed per approved plans, 2024 ISPSC with Chandler amendments. Pool barrier compliance verified.

Applies to: Certificate of Occupancy / Change of Occupancy

  1. 1

    Certificate of Occupancy

    Final verification that all applicable trade inspections are approved and the building/space meets code for the occupancy classification requested, per the City's published Building Inspection Codes (Miscellaneous group, code 782).

  2. 2

    Certificate of Completion

    Issued instead of a full C of O when the completed work does not change the scope of an existing C of O or does not result in a building ready for occupancy (City Code §29-2.15, Subsection 111.5; Miscellaneous group, code 783). Does not itself authorize occupancy.

Applies to: EV Charger / EVSE Permit

  1. 1

    Rough-In

    New circuit wiring, box placement, and panel/sub-panel connections before walls are closed, if applicable

  2. 2

    Final

    Charger unit installed, dedicated circuit capacity and wire sizing verified per the 2023 NEC with Chandler amendments

Applies to: Residential Solar Photovoltaic (PV) System Permit

  1. 1

    Rough electrical (if applicable)

    If roof penetrations, conduit runs, or sub-panel work is included, rough electrical inspection prior to cover.

  2. 2

    Final inspection

    Solar PV system completed per approved plans, 2023 NEC, and 2024 IBC/IRC with Chandler amendments.

Applies to: Roofing Permit

  1. 1

    Lath inspection (if stucco re-cladding)

    All substrate wire mesh and trim installed, ready to receive stucco, but not covered. One-coat stucco systems always require permit and inspection; verify ICC-ES report for one-coat system.

  2. 2

    Final inspection

    Roofing work completed to the requirements of the approved plans and city codes.

Applies to: Sign Permit (Commercial / Business Signage)

  1. 1

    520-Electrical / 530-Footing

    Required for illuminated wall signs and new freestanding monument signs; must be approved prior to scheduling the 510-Final inspection. Schedule by calling (480) 782-3100.

  2. 2

    510-Final

    All signs must be inspected after installation is complete. Non-illuminated wall signs and monument sign panels only need this final inspection (no electrical/footing inspection required).

Re-inspection fees

Residential Building Permit (New Home / Addition / Remodel)Re-inspection fee · City of Chandler Fee Schedule, Section 4.6.3(b).
$60.00/hour, 1-hour minimum
Commercial Fire Sprinkler / Fire Alarm System PermitRe-inspection fee · City of Chandler Fee Schedule, Section 4.6.3(b), applies generally to re-inspections including fire protection inspections.
$60.00/hour, 1-hour minimum

Sources & verification

Verified against official sources. Last reviewed 2026-07-16.

Fees, timelines, and adopted codes are researched from each jurisdiction's published records — see how we verify. Requirements change and vary by project, so always confirm the current details with the Chandler building department before you submit. PermitBase is an independent reference and is not affiliated with any government agency.

Chandler building permits

Get alerts for Chandler

We'll email you when Chandler's fees, documents, or codes change — not often.

We only use your email to send permit updates. No spam, unsubscribe anytime. Privacy.