Deck / Patio Cover / Carport Permit in Kersey, Colorado

Covers decks, patio covers, and carports in Kersey, reviewed under the 2024 IRC per the Town's dedicated 'Decks' (5-page) and 'Patio Covers/Carports' (5-page) SAFEbuilt homeowner guides. RESOLVED 2026-07-23: both PDFs were re-downloaded and their full text confirmed directly (previously only their existence and cover-page heading had been confirmed).

Verified 2026-07-23 · Source

When you need this permit

  • Site Plan required showing setbacks, easements, property lines, and distance to other structures; structures may not be built over setback lines/easements/property lines; a registered land surveyor's survey is required in protected areas, an as-built survey if within 12 in. of a required minimum setback
  • Deck construction: lumber grade #2 or better, pressure-treated ACQ or CA-B, ground-contact-rated where touching ground; deck ledger attached to the house with a minimum 15/32 in. structural sheathing and fasteners spaced per IRC Table R507.9.1.3(2); guardrail required (36 in. height) where the deck floor exceeds 30 in. above grade, with a 4 in. sphere rule for baluster spacing; handrail required on stairs with 4+ risers (34-38 in. above nosing); stairways not less than 36 in. wide; footings to local frost depth with posts attached per IRC R507.3 (metal pedestal projecting 1 in. above concrete, 6 in. above exposed earth)
  • Patio cover/carport construction: limited to 12 ft maximum height; roof-covering, pitch, underlayment, and sheathing to be specified on the plan; if any side is within 5 ft of the property line, that side must be enclosed with a solid 1-hour fire-rated wall, but at least 2 sides of a carport must remain open per the Building Code; roof tie-downs and galvanized post-beam connectors required at post attachments; pergolas not requiring roof-load transfer are generally exempt from the structural design requirements but a permit may still be required — check with the local municipality
  • Standard inspections for both structure types: Footing (after excavation/rebar/forms, before concrete), Framing (rim/ledger/rafter/beam attachment before finish materials, plus rough electrical if wired), and Final

Required documents

Check off what you have — your progress is saved on this device.

Not ready yet0 of 1 required documents checked.

This checker covers one permit. A full project usually triggers several — our paid checklist will assemble all of them, from $29

Fee schedule

Building Permit Fee (valuation-based)No standalone deck-specific fee line item found in either published fee document
Set by SAFEbuilt per UBC valuation of the deck/patio cover/carport

Review timeline

Plan review
Not published — contact the department

How long did your Deck / Patio Cover / Carport Permit permit actually take in Kersey?

Anonymous — one question, no email. Answers are combined and only shown once at least 5 people have reported.

Inspection process

  1. 1

    Footing Inspection

    After holes/trenches excavated and reinforcing steel/forms in place, prior to concrete placement

  2. 2

    Framing Inspection

    Rim board/ledger attachment, floor joists, beams, hangers (decks) or roof/truss/rafter attachment (patio covers/carports) prior to finished flooring or ceiling being applied; a rough electrical inspection is called at the same time if electric is being installed for a patio cover/carport

  3. 3

    Final Inspection

    After the deck or patio cover/carport is completed, including any final electrical

See the full Kersey inspection guide — scheduling & re-inspection fees →

Tips

  • Kersey publishes separate guides for Decks and for Patio Covers/Carports — confirm you are using the correct guide for your specific structure type rather than assuming one covers both.
  • Patio covers/carports within 5 ft of the property line need a solid 1-hour fire-rated wall on that side, but the Building Code requires at least 2 sides of a carport to remain open — plan your layout accordingly.
  • Pergolas typically don't need to be designed for roof/snow load transfer, but the guide notes a permit may still be required depending on the municipality — confirm with SAFEbuilt before assuming a pergola is exempt.

Frequently asked questions

Kersey requires a deck / patio cover / carport permit for: Site Plan required showing setbacks, easements, property lines, and distance to other structures; structures may not be built over setback lines/easements/property lines; a registered land surveyor's survey is required in protected areas, an as-built survey if within 12 in. of a required minimum setback; Deck construction: lumber grade #2 or better, pressure-treated ACQ or CA-B, ground-contact-rated where touching ground; deck ledger attached to the house with a minimum 15/32 in. structural sheathing and fasteners spaced per IRC Table R507.9.1.3(2); guardrail required (36 in. height) where the deck floor exceeds 30 in. above grade, with a 4 in. sphere rule for baluster spacing; handrail required on stairs with 4+ risers (34-38 in. above nosing); stairways not less than 36 in. wide; footings to local frost depth with posts attached per IRC R507.3 (metal pedestal projecting 1 in. above concrete, 6 in. above exposed earth); Patio cover/carport construction: limited to 12 ft maximum height; roof-covering, pitch, underlayment, and sheathing to be specified on the plan; if any side is within 5 ft of the property line, that side must be enclosed with a solid 1-hour fire-rated wall, but at least 2 sides of a carport must remain open per the Building Code; roof tie-downs and galvanized post-beam connectors required at post attachments; pergolas not requiring roof-load transfer are generally exempt from the structural design requirements but a permit may still be required — check with the local municipality; Standard inspections for both structure types: Footing (after excavation/rebar/forms, before concrete), Framing (rim/ledger/rafter/beam attachment before finish materials, plus rough electrical if wired), and Final. If your project isn't listed, confirm with Town of Kersey Building Inspection Department (building inspection services contracted to SAFEbuilt Colorado, Windsor Office) at 970-353-1681 before starting work.

In Kersey, the published Building Permit Fee (valuation-based) is: Set by SAFEbuilt per UBC valuation of the deck/patio cover/carport. These are the jurisdiction's own published figures — see the fee schedule table and source citations on this page.

Kersey does not publish a plan-review timeline for this permit. Contact Town of Kersey Building Inspection Department (building inspection services contracted to SAFEbuilt Colorado, Windsor Office) at 970-353-1681 for current turnaround.

You'll need: Deck / Patio Cover / Carport Permit Application. See the required-documents checklist on this page for details on each.

Kersey requires 3 inspection(s) for a deck / patio cover / carport permit, in order: Footing Inspection, Framing Inspection, Final Inspection. Schedule each through Town of Kersey Building Inspection Department (building inspection services contracted to SAFEbuilt Colorado, Windsor Office) (970-353-1681).

Apply through Town of Kersey Building Inspection Department (building inspection services contracted to SAFEbuilt Colorado, Windsor Office) at 446 1st Street, P.O. Box 657, Kersey, CO 80644. Phone: 970-353-1681, email: kdamrell@kerseygov.com. Office hours: Not published on the Town of Kersey website (Building Inspection Department page, Administration Department page, or building permit how-to page were all checked directly). Town Hall main line 970-353-1681; SAFEbuilt Windsor office line 970-686-7511 (cited on the Town's Current Building Regulations page for building-code clarification); SAFEbuilt inspection requests may also be emailed to windsor@safebuilt.com per the Town's Re-Roofing guide.. Official information: https://www.kerseygov.com/departments/building_inspection_department/index.php.

Kersey, Colorado has adopted: 2024 International Residential Code (IRC) — actively cited as the current adopted code on all nine of the Town's SAFEbuilt-published 'Building Guides for Homeowners' (Additions, Accessory Structures, Re-Roofing, Basement Finish, Decks, Patio Covers/Carports, Window Replacement, Pole Barns, Swimming Pools), each stamped 'Document published by SAFEbuilt, Inc. 1.1.2026' and headed '2024 IRC' — these are the Town's most recently updated, actively maintained permitting documents (site-wide document-center timestamps show a 2026-03-30 publish date).; 2020 National Electrical Code (NEC) — per the Town's Planning Department 'Current Building Regulations' page, which references a '2020 NEC - Significant Changes Residential Electrical' resource alongside the Municipal Code Chapter 18 structure.; RESOLVED 2026-07-23 (live primary source, Municode Library, library.municode.com/co/kersey, Kersey Municipal Code 'VERSION: OCT 23, 2025 (CURRENT)', codified through Ordinance No. 2025-0008 enacted 6/10/2025): the Municipal Code's own home page lists 'Adopted Ordinances Not Yet Codified,' including Ordinance No. 2025-0010, adopted 9/9/2025, titled verbatim 'AN ORDINANCE ADOPTING BY REFERENCE THE INTERNATIONAL BUILDING CODE, 2024 EDITION, THE INTERNATIONAL RESIDENTIAL CODE, 2024 EDITION, THE INTERNATIONAL FUEL GAS CODE, 2024 EDITION, THE INTERNATIONAL PLUMBING CODE, 2024 EDITION, THE INTERNATIONAL MECHANICAL CODE, 2024 EDITION, THE INTERNATIONAL EXISTING BUILDING CODE, 2024 EDITION, THE INTERNATIONAL PROPERTY MAINTENANCE CODE, 2024 EDITION, THE INTERNATIONAL SWIMMING POOL and SPA CODE, 2024 EDITION, AND THE INTERNATIONAL ENERGY CONSERVATION CODE, 2024 EDITION, PROMULGATED BY THE INTERNATIONAL CODE COUNCIL.' This is a real, dated, numbered ordinance (not a guess or inference) and directly confirms the SAFEbuilt-published '2024 IRC' guides were current and correct — the Town has adopted 2024 editions of IBC, IRC, IFGC, IPC, IMC, IEBC, IPMC, ISPSC, and IECC, superseding the 2018/2012 editions still shown in Chapter 18's currently-codified section text (Sec. 18-19 Building Code = 2018 IBC, Sec. 18-44 Residential Code = 2018 IRC, Sec. 18-64 Mechanical Code = 2018 IMC, Sec. 18-89 Fuel Gas Code = 2018 IFGC, Sec. 18-109 Plumbing Code = 2018 IPC, Sec. 18-134 Energy Conservation Code = 2012 IECC, Sec. 18-154 Property Maintenance Code = 2018 IPMC, Sec. 18-179 Existing Building Code = 2018 IEBC) — those codified sections simply have not yet been updated in Municode's online supplement to reflect the 9/9/2025 ordinance, exactly as the Municode banner itself discloses ('This Code of Ordinances... may not reflect the most current legislation adopted by the Municipality'). Notably, Ordinance No. 2025-0010's list does NOT include the International Fire Code — Article X (Sec. 18-199, adopted separately by Ordinance No. 2021-0001) remains the 2018 International Fire Code with no 2024-edition update found. Per this corpus's practice of treating the more current, actively-distributed and now ordinance-confirmed source as authoritative, this file treats IBC/IRC/IFGC/IPC/IMC/IEBC/IPMC/ISPSC as 2024 editions (per Ord. No. 2025-0010, 9/9/2025) and IFC as the 2018 edition (per Ord. No. 2021-0001, 1/12/2021, locally amended by Sec. 18-200) — the prior 'partial' flag on the non-residential code editions is resolved.; HB22-1362 (Colorado statewide energy code floor, 2021 IECC + electric/solar/EV-ready provisions, effective window July 2023-July 2026): RESOLVED IN PART 2026-07-23 — Municode confirms Chapter 18, Article VII (Sec. 18-134) currently codifies the 2012 IECC (not the ambiguous, undated 'Energy Conservation Code' the static Current Building Regulations page implied), and the same live Ordinance No. 2025-0010 (adopted 9/9/2025, not yet codified) adopts by reference the 2024 IECC, which post-dates and satisfies HB22-1362's 2021-IECC-floor requirement. The Home Additions guide's instruction to submit an 'Energy Code Compliance Report (www.energycodes.gov) or REScheck calculations' is consistent with 2024 IECC compliance documentation but still does not itself name an edition year — the 2024 IECC edition-year figure comes from the Ordinance 2025-0010 citation above, not from the SAFEbuilt guide.. Local amendments apply — see the Kersey overview page for the full list.

If any side is closer than 5 feet to the property line, that side must be enclosed with a solid 1-hour fire-rated wall per the Town's guide, though at least 2 sides of a carport must remain open to conform to the Building Code.

Sources & verification

Verified against official sources. Last reviewed 2026-07-23.

Fees, timelines, and adopted codes are researched from each jurisdiction's published records — see how we verify. Requirements change and vary by project, so always confirm the current details with the Kersey building department before you submit. PermitBase is an independent reference and is not affiliated with any government agency.