Skip to main content
PermitBase

Plumbing Permit in Riverton, Wyoming

Required for plumbing installations, alterations, and repairs in Riverton. Governed by the 2024 International Plumbing Code with local amendments (RMC Chapter 15.04), including simplified rough-in testing procedures.

Verified 2026-07-01 · Source

When you need this permit

  • Plumbing alteration, sanitary sewer replacement, gas line testing, water heater installation/replacement
  • DWV systems (underslab only) tested on completion of rough piping by water (10 ft head, 15 min hold) or air (5 psi / 10 in. Hg, 15 min hold) test — Schedule 40 PVC allowed to be tested with air (locally amended IPC §§ 312.1, 312.3 and IRC § P2503.5.1)
  • Backflow prevention: required check valve and expansion tank status noted on the application form
  • Water tap size 2 inches or greater requires DEQ (Wyoming Dept. of Environmental Quality) review

Required documents

Check off what you have — your progress is saved on this device.

Not ready yet0 of 1 required documents checked.

This checker covers one permit. A full project usually triggers several — our checklist will assemble all of them, free →

Fee schedule

Plumbing AlterationCity of Riverton Resolution No. 1355, Category 3.B.5
$26.00 minimum
Water Heater Replacement (residential)Resolution No. 1355, Category 3.B.6
$26.00 minimum
Gas Piping TestResolution No. 1355, Category 3.B.7
$26.00 per test or trip
Water or Sewer ReplacementResolution No. 1355, Category 3.B.8
$52.00

Review timeline

Plan reviewTypical estimate — confirm current times with the Riverton building department
~1–10 business days

How long did your Plumbing Permit permit actually take in Riverton?

Anonymous — one question, no email. Answers are combined and only shown once at least 5 people have reported.

Inspection process

  1. 1

    Underground Plumbing

    After all underground waste/vent/water plumbing installed and pressure tested, before backfill/concrete

  2. 2

    Rough Plumbing

    After all waste, vent, and water piping is installed, before insulation/sheetrock

  3. 3

    Final

    Part of the project's overall Final Inspection

See the full Riverton inspection guide — scheduling & re-inspection fees →

Tips

  • Riverton locally amended the IPC/IRC drain-waste-vent testing sections to a simplified standard: a 10-foot water column held 15 minutes, OR a 5 psi (10 in. Hg) air test held 15 minutes, with Schedule 40 PVC explicitly allowed to be tested with air.
  • Water/sewer tap sizes of 2 inches or greater trigger a mandatory Wyoming DEQ review — factor this into your project timeline.
  • Water & Sewer Plant Investment Fees (tap fees) are billed separately from building-permit plumbing fees — see the City's 'Water & Sewer Plant Investment Fees' schedule (Resolution No. 1521, revised April 1, 2025) for utility connection costs.

Frequently asked questions

Riverton requires a plumbing permit for: Plumbing alteration, sanitary sewer replacement, gas line testing, water heater installation/replacement; DWV systems (underslab only) tested on completion of rough piping by water (10 ft head, 15 min hold) or air (5 psi / 10 in. Hg, 15 min hold) test — Schedule 40 PVC allowed to be tested with air (locally amended IPC §§ 312.1, 312.3 and IRC § P2503.5.1); Backflow prevention: required check valve and expansion tank status noted on the application form; Water tap size 2 inches or greater requires DEQ (Wyoming Dept. of Environmental Quality) review. If your project isn't listed, confirm with City of Riverton Community Development Department — Building Division at (307) 856-2999 before starting work.

In Riverton, the published Plumbing Alteration is: $26.00 minimum. Additional published fees: Water Heater Replacement (residential) — $26.00 minimum; Gas Piping Test — $26.00 per test or trip; Water or Sewer Replacement — $52.00. These are the jurisdiction's own published figures — see the fee schedule table and source citations on this page.

Plan review for a plumbing permit in Riverton typically runs 1–10 business days. This is an estimate, not a published figure — confirm current review times with City of Riverton Community Development Department — Building Division at (307) 856-2999.

You'll need: Application for Building Permit. See the required-documents checklist on this page for details on each.

Riverton requires 3 inspection(s) for a plumbing permit, in order: Underground Plumbing, Rough Plumbing, Final. Schedule each through City of Riverton Community Development Department — Building Division ((307) 856-2999).

Apply through City of Riverton Community Development Department — Building Division at 816 N. Federal Blvd., Riverton, WY 82501. Phone: (307) 856-2999, email: kpetersen@rivertonwy.gov. Office hours: Mon–Fri (contact department for current hours); building permitting/inspection line (307) 857-7708. Official information: https://www.rivertonwy.gov/departments/community_dev/building_permits___inspections/index.php.

Riverton, Wyoming has adopted: 2024 International Building Code (IBC), including appendices A, B, C, F, H, I, J, K — adopted by Enrolled Ordinance No. 25-003 (effective March 22, 2025); 2024 International Residential Code (IRC), including appendices AA, BA, BB, BC, BD, BE, BF, BG, BH, BO, CA, CB, CC, CD, CE, CF (excluding Chapter 11) — Ordinance No. 25-003; 2024 International Mechanical Code (IMC), including appendix A — Ordinance No. 25-003; 2024 International Plumbing Code (IPC), including appendices C, D, E, F — Ordinance No. 25-003; 2024 International Fuel Gas Code (IFGC), including appendices A, B, C, D — Ordinance No. 25-003; 2024 International Fire Code (IFC), including appendices A–G — Ordinance No. 25-003; 2024 International Code Council Performance Code (ICCPC) — Ordinance No. 25-003; 2024 International Property Maintenance Code (IPMC), including appendices A, B — Ordinance No. 25-003; 2024 International Existing Building Code (IEBC) — Ordinance No. 25-003; National Electrical Code (NEC) — NFPA 70; Riverton Municipal Code § 15.08.110(B)(2) ties compliance to 'the latest edition of the National Electrical Code,' which per wsfm.wyo.gov/electrical-safety is now the 2026 edition, effective statewide July 1, 2026 (the 2023 edition was the applicable 'latest edition' from July 1, 2023 until then) — adopted by the City of Riverton itself as Riverton Municipal Code Chapter 15.08 'Electrical Code'; enforced by the city's own electrical inspector, NOT solely the Wyoming State Fire Marshal's default statewide program; National Fire Codes (NFC), current editions, NFPA; National Housing Construction and Safety Standards Act of 1974 (as amended through May 30, 2006, HUD) — governs manufactured/mobile home construction; ICC/ANSI A117.1-2017 — Accessible and Usable Buildings and Facilities. Local amendments apply — see the Riverton overview page for the full list.

Per the city's locally amended IRC/IPC provisions, underslab DWV systems are tested on completion of rough piping by either a water test (filled to 10 feet above the highest fitting, held 15 minutes) or an air test (5 psi / 10 inches of mercury, held 15 minutes without added air). Schedule 40 PVC may be tested with air.

Sources & verification

Verified against official sources. Last reviewed 2026-07-01.

Fees, timelines, and adopted codes are researched from each jurisdiction's published records — see how we verify. Requirements change and vary by project, so always confirm the current details with the Riverton building department before you submit. PermitBase is an independent reference and is not affiliated with any government agency.