Somerton building inspections
VerifiedInspection sequence, scheduling, and re-inspection fees for building permits in Somerton, Arizona.
Verified 2026-07-06 · Source
How to schedule
Inspections are requested through the building department below.
- Address
- 143 N. State Ave. (2nd Floor), P.O. Box 638, Somerton, AZ 85350
- Phone
- 928-722-7399
- Office hours
- City Hall hours as of August 12, 2024: closed every other Friday (contact 928-722-7400 for the current schedule); Building Inspector observes modified Summer Hours during peak heat months. To schedule a building inspection, call (928) 722-7399 before 3:00 PM Monday-Friday, or email Maria Ybarra (Permit Technician), at least one business day in advance. Plans/applications may be submitted via the On-line Permit Portal, by email, or in person at 143 N. State Ave.
- Website
- Official site
Inspection sequence
Applies to: New Residential Building Permit
- 1
Foundation/Footing
Before concrete pour
- 2
Framing
Structural framing, connections, plumbing/electrical rough-in per 2018 IRC and City of Somerton amendments
- 3
Final
Completed work verified against approved plans prior to Certificate of Occupancy
Applies to: Plumbing Permit
- 1
Underground/Slab
Before concrete pour — verify pipe slope, materials, cleanouts
- 2
Rough-In
After pipes installed, before walls closed
- 3
Final
Fixtures connected, water heater and gas connections verified, no leaks
Applies to: Demolition Permit
- 1
Pre-Demolition/Utility Disconnect Inspection
Verifies utilities have been properly terminated before demolition begins
- 2
Final Demolition Inspection
Confirms complete removal of structure and site clearance; two inspections are required per Resolution No. 2026-004
Applies to: Electrical Permit
- 1
Rough-In
Wiring, box placement, and panel connections before walls are closed
- 2
Final / Clearance
Devices installed, panel labeled, protections verified per 2014 NEC
Applies to: EV Charger / EVSE Permit
- 1
Rough-In
Wiring, box placement, and panel connections before walls are closed
- 2
Final / Clearance
Charging equipment installed, circuit labeled, protections verified per 2014 NEC
Applies to: Fence / Block Wall Permit
- 1
Footing/Pre-Pour
Required prior to placing footing concrete and grouting activities per City of Yuma Standard No. 3-310
- 2
Final
Completed wall verified for height, reinforcement, and setback/visibility-triangle compliance
Applies to: Mechanical / HVAC Permit
- 1
Rough-In
Ductwork and equipment placement before walls closed
- 2
Final
Equipment operational, clearances and combustion air verified
Applies to: Residential Remodel / Addition Permit
- 1
Foundation/Framing (if applicable)
Required for additions and structural remodels prior to closing walls
- 2
Final
Completed work verified against approved plans
Applies to: Residential Solar Photovoltaic (PV) Permit
- 1
Rough Electrical
Conduit runs, wire sizing, disconnect placement before energizing
- 2
Final
Panel mounting, racking attachment, roof penetration sealing, electrical connections, and interconnection point verified
Sources & verification
Verified against official sources. Last reviewed 2026-07-06.
Fees, timelines, and adopted codes are researched from each jurisdiction's published records — see how we verify. Requirements change and vary by project, so always confirm the current details with the Somerton building department before you submit. PermitBase is an independent reference and is not affiliated with any government agency.
Somerton building permits
Get alerts for Somerton
We'll email you when Somerton's fees, documents, or codes change — not often.
We only use your email to send permit updates. No spam, unsubscribe anytime. Privacy.