Golden building inspections
VerifiedInspection sequence, scheduling, and re-inspection fees for building permits in Golden, Colorado.
Verified 2026-07-05 · Source
How to schedule
Inspections are requested through the building department below.
- Address
- 911 10th Street, Golden, CO 80401 (Building Department); Planning Department at 1445 10th Street, Golden, CO 80401
- Phone
- (303) 384-8151
- Office hours
- Monday-Friday, general City Hall hours (main line (303) 384-8000); Building Department direct line (303) 384-8151
- Website
- Official site
Published scheduling rules
- Applications, contractor licensing, and inspection requests are submitted via the City's Accela-based Online Permitting Portal (Residential Building Permit (New Construction))
- Inspection requests require BOTH an online portal request AND a separate email to fireinspections@cityofgolden.net, at least 2 business days ahead — a portal request alone may not be sufficient. (Fire Sprinkler / Fire Alarm System Permit)
- Inspections must be requested via the online permitting portal AND an email to fireinspections@cityofgolden.net at least 2 business days in advance (Fire Sprinkler / Fire Alarm System Permit)
Inspection sequence
Applies to: Commercial Building Permit
- 1
Footing / Caisson
Before concrete pour
- 2
Concrete Reinforcing
Reinforcing steel in place before pour
- 3
Foundation and Damp Proofing
Before backfilling
- 4
Rough Plumbing / Gas Pipe
Drain-waste-vent, water piping, and fuel-gas piping before concealment
- 5
Rough Heating / Rough Electrical
Ductwork, flues, refrigeration lines, panels, and wiring before concealment
- 6
Rough Frame
Structural framing complete before cover
- 7
Insulation
Insulation installed per 2024 IECC before drywall
- 8
Drywall
Drywall attachment before taping/finishing
- 9
Fire system acceptance tests (GFD)
Sprinkler rough/hydro and fire alarm 100% pretest with NFPA 72 Record of Completion, witnessed by the Golden Fire Department under the separate fire permits; request via the portal at least 2 business days in advance; stamped plans must be on-site
- 10
Final Inspections (Building, Plumbing, Heating, Electrical)
All trades complete per approved plans; Knox Box installed prior to final where required
Applies to: Commercial Tenant Improvement (Interior Commercial Alteration) Permit
- 1
Rough Plumbing / Gas Pipe
New or relocated plumbing and fuel-gas piping before concealment
- 2
Rough Heating / Rough Electrical
Ductwork and wiring modifications before concealment
- 3
Rough Frame
New interior partitions and structural modifications before cover
- 4
Insulation
Where wall/ceiling assemblies are modified, per the 2024 IECC
- 5
Drywall
Attachment inspection before taping/finishing
- 6
Fire system acceptance tests (GFD, if applicable)
Sprinkler modifications (rough/hydro) and fire alarm 100% pretest with NFPA 72 Record of Completion; kitchen hood test (manual pull, fusible link, fuel/make-up-air shutdown, Class K extinguisher placement); request via portal 2+ business days ahead with stamped plans on-site
- 7
Final Inspections (Building, Plumbing, Heating, Electrical)
All work complete per approved plans before occupancy of the altered space
Applies to: Residential Building Permit (New Construction)
- 1
Foundation / Footing or Caisson
Before concrete pour
- 2
Foundation and Damp Proofing
Before backfilling — defects grouted and damp-proofing applied below backfill line
- 3
Rough Frame
Interior partitions, framing, sub-flooring, and stairs completed before cover
- 4
Rough Plumbing / Rough Electrical / Rough Heating
Rough-in of plumbing (drain/waste/vent, water piping), electrical (panel and wiring), and heating (ductwork, flues, hot water, refrigeration lines) before concealment; may be combined into a Combination Inspection
- 5
Final Inspection
All work complete per approved plans and applicable codes
Applies to: Accessory Dwelling Unit (ADU) Permit
- 1
Foundation
Before concrete pour, 36-inch minimum frost depth
- 2
Rough Frame
Framing complete, fire sprinkler rough-in verified for new detached ADUs
- 3
Rough Plumbing / Electrical / Heating
Trade rough-ins before concealment
- 4
Final Inspection
All work complete, occupancy limit and utility-connection compliance confirmed
Applies to: Residential Addition / Remodel Permit
- 1
Foundation (if new footings)
Before concrete pour, per 36-inch minimum frost depth
- 2
Rough Frame
Framing, sub-flooring, stairs complete before cover
- 3
Rough Plumbing / Electrical / Heating
Trade rough-ins before concealment
- 4
Final Inspection
All work complete per approved plans
Applies to: Electrical Permit
- 1
Rough Electrical
Requested once wiring is installed and the main panel is completed, before concealment
- 2
Final Inspection
All devices installed, panel labeled, system energized and verified
Applies to: EV Charger / Electric Vehicle Charging Station Permit
- 1
Rough Electrical
Requested once wiring is installed and any new panel/circuit work is completed, before concealment
- 2
Final Inspection
New circuit, breaker sizing, and disconnect (if required) verified before the charger is energized
Applies to: Fire Sprinkler / Fire Alarm System Permit
- 1
Rough-In / Hydrostatic Inspection
All fire suppression projects require rough/hydrostatic inspections with all sprinkler piping visible for inspection
- 2
Final Inspection
Requires completed back-flow certifications, underground/aboveground/standpipe test certificates, and IFC 901.2.1 statements of compliance, uploaded to Accela
Applies to: Mechanical / HVAC Permit
- 1
Rough Heating
Requested once all ductwork, flues, heating, hot water, and refrigeration lines are installed but not yet covered or concealed
- 2
Final Inspection
Equipment operational; combustion air and venting verified
Applies to: Plumbing Permit
- 1
Rough Plumbing
Requested after plumbing pipes are installed; underground plumbing, drains, vents, and water piping may be inspected together or separately
- 2
Final Inspection
Fixtures connected, no leaks, proper venting verified
Applies to: Roofing Permit (Reroof)
- 1
Mid-Roof
Required when 25%-65% of new roof covering has been installed; secured ladder extended 3+ feet above roofline required for inspector access
- 2
Final Inspection
Completed roof — flashing, ice barrier, ventilation, and fire-rating compliance verified
Applies to: Solar PV Permit
- 1
Rough Electrical
Conduit runs, wire sizing, and disconnect placement before cover, per standard electrical permit inspection sequence
- 2
Final Inspection
Racking, roof penetrations, and electrical connections verified
Final inspection only: Change of Use / Change of Occupancy, Demolition Permit, Fence / Retaining Wall Permit
Re-inspection fees
Construction Permit / Operational Permit Fee · Fees apply to plan review (which includes initial inspections/witness testing); Show full citationHide
Construction Permit / Operational Permit Fee · Fees apply to plan review (which includes initial inspections/witness testing); re-reviews, re-inspections, and after-hours inspections may incur additional fees. See the separate fee schedule on the Fire & Life Safety Bureau's webpage.Sources & verification
Verified against official sources. Last reviewed 2026-07-05.
Fee schedules
Checklists & handouts
Online permit portal
Codes & ordinances
Department & other records
Fees, timelines, and adopted codes are researched from each jurisdiction's published records — see how we verify. Requirements change and vary by project, so always confirm the current details with the Golden building department before you submit. PermitBase is an independent reference and is not affiliated with any government agency.