Required for re-roofing work in Eaton, governed by Chapter 9 (Sec. R901-R908) of the 2024 IRC as adopted, plus the Town's own dedicated Roofing Regulations handout and a locally amended Class-4 impact-resistant shingle requirement.
Verified 2026-07-06 · Source
When you need this permit
- Building Permit shall be posted on the house prior to starting work
- Roofing Contractor must carry $100,000 combined single limit liability insurance; certificate of insurance (with limits, policy number, insurer name, effective/expiration dates) submitted at time of application, with an endorsement requiring 10-day advance written notice to the Town before cancellation
- Re-roofing performed per Chapter 9 of the 2024 IRC: ice barrier required from the lowest roof edges to at least 24 inches inside the exterior wall line; all existing roofing materials must be torn off down to the deck (one-layer overlay rarely permitted); materials must meet 2024 IRC fire classification and wind-resistance standards; drip edge required at eaves and gables
- Asphalt shingles must be Class 4 impact resistant, tested to UL2218, installed per manufacturer instructions — a local amendment to IRC R905.2.4
- Replace damaged roof vents, b-vents, and roof jacks; add roof vents as needed to comply with 2024 IRC Sec. 806 (Roof Ventilation)
- Secured ladder required on-site for all inspections (Code Reference R109.3)
- Repair or replacement of less than 1 square (100 sq ft) of shingles does NOT require a building permit, per both the Roofing Regulations handout and Ordinance No. 664's IRC Sec. 105.2/R105.2 exemption amendment
Required documents
Check off what you have — your progress is saved on this device.
Not ready yet — 0 of 2 required documents checked.
This checker covers one permit. A full project usually triggers several — our paid checklist will assemble all of them, from $29 →
Fee schedule
Review timeline
Inspection process
- 1
Mid-Roof Inspection
Required for tile roofs and commercial flat roofs only
- 2
Final Inspection
Verifies completed roof is up to code and all debris removed; a secured ladder must be provided for the inspector; Remote Video Inspection (RVI) option available
See the full Eaton inspection guide — scheduling & re-inspection fees →
Tips
- Eaton's Roofing Regulations handout requires Class 4 impact-resistant asphalt shingles (UL2218-tested) as a local amendment to IRC R905.2.4 — this is a stricter-than-baseline-IRC requirement, confirm your shingle product meets this standard before purchasing materials.
- Schedule inspections at least 24 hours in advance by calling 970-305-3161 ext. 1 (SAFEbuilt); clean up all debris and clear gutters before calling for final inspection.
- Re-roofs replacing less than 1 square (100 sq ft) of shingles do not require a permit at all — confirm your project's exact scope before assuming a permit is needed.
Frequently asked questions
Sources & verification
Verified against official sources. Last reviewed 2026-07-06.
Fees, timelines, and adopted codes are researched from each jurisdiction's published records — see how we verify. Requirements change and vary by project, so always confirm the current details with the Eaton building department before you submit. PermitBase is an independent reference and is not affiliated with any government agency.
Other permits in Eaton
Roofing Permit (Re-Roof) in other cities
Compare roofing permit (re-roof) fees across Colorado →
Look up this fee in a different city →
Related guides
Now live
Build your Eaton project checklist
Describe your project once and get every permit, document, and fee it triggers in Eaton — in one checklist. Sign up and pay once to generate it, or go unlimited with Pro.
Get started →