West Jordan building inspections
VerifiedInspection sequence, scheduling, and re-inspection fees for building permits in West Jordan, Utah.
Verified 2026-06-29 · Source
How to schedule
Inspections are requested through the building department below.
- Address
- 8000 South Redwood Road, West Jordan, UT 84088
- Phone
- (801) 569-5050
- Office hours
- Mon–Fri 8:00 AM – 5:00 PM
- Website
- Official site
Inspection sequence
Applies to: Accessory Dwelling Unit (ADU)
- 1
Foundation
Footings, forms, rebar — before concrete pour
- 2
Framing
Structure, fire separation if applicable, egress windows
- 3
MEP Rough-In
Mechanical, electrical, plumbing rough-ins before walls closed
- 4
Insulation
Insulation and vapor barrier before drywall
- 5
Final
All work complete, smoke/CO detectors, address posted, ready for occupancy
Applies to: Basement Finish Permit
- 1
Framing
Wall framing, fire blocking, egress window wells and openings
- 2
MEP Rough-In
Electrical, plumbing, and HVAC rough-ins before walls closed
- 3
Insulation
Insulation on exterior walls, vapor barrier placement
- 4
Final
Drywall, fixtures, smoke/CO detectors, and all finishes complete
Applies to: Residential Building Permit
- 1
Foundation / Footing
Before concrete pour — verify excavation, forms, rebar, and anchor bolts
- 2
Framing
After framing, sheathing, and roof — before insulation or wall cover
- 3
Insulation
After insulation installed, before drywall
- 4
Final
All work complete, ready for occupancy
Applies to: Commercial Building Permit
- 1
Foundation / Footing
Before concrete pour, per standard IBC inspection sequence.
- 2
Framing
After framing, sheathing, and roof installed.
- 3
Final
All work complete before occupancy.
Applies to: Deck Permit
- 1
Footing
Before concrete pour — verify footing depth (minimum 30 inches per frost depth) and size
- 2
Framing
After framing complete — ledger, joists, beams, and railing posts
- 3
Final
All work complete per approved plans, including railing height and guards
Applies to: Electrical Permit
- 1
Rough-In
After wiring installed, before walls closed — verify box placement, wire sizing, and proper support
- 2
Service / Panel
Panel installation, grounding electrode system, service entrance conductors
- 3
Final
All devices installed, GFCI/AFCI protection verified, panel labeled
Applies to: Plumbing Permit
- 1
Underground / Slab
Before concrete pour — verify pipe slope, materials, and cleanouts
- 2
Rough-In
After pipes installed, before walls closed — pressure test required
- 3
Final
All fixtures connected, water flowing, no leaks, proper venting verified
Applies to: Zoning Verification Letter / Certificate of Occupancy Inspection (Planning & Engineering)
- 1
Final Inspection (Certificate of Occupancy and Zoning Compliance)
A certificate of occupancy and zoning compliance is issued by the city administrator or a designee only after the property development/building is completed and has passed final inspection, per § 13-1-9.
- 2
Certificate of Occupancy Inspection (Planning/Engineering)
Site-level Planning/Engineering inspection verifying compliance with approved development conditions, distinct from the Building Division's own final inspection. First reinspection is included at no charge; each additional reinspection is $75.00.
- 3
Temporary Certificate Bond-Release Inspection
Where a temporary certificate was issued against a cash bond (100%/150% of estimated completion costs, per § 13-1-9), an inspection must be scheduled with city staff to confirm all zoning/site plan/other approval conditions have since been met before the bond is released and permanent occupancy/use is granted.
Applies to: Commercial Tenant Improvement / Tenant Finish Permit
- 1
Framing / Structural
Where applicable to the tenant-improvement scope, before close-in.
- 2
Final
All work complete before occupancy.
Applies to: Demolition Permit
- 1
Pre-Demolition
Verify utility disconnects, Air Quality approval, and Health Department pre-demolition inspection are complete before work begins
- 2
Final / Site Clear
Site cleared, foundation removed or capped, erosion control in place
Applies to: EV Charger / EVSE Permit
- 1
Service / Panel
Panel installation, grounding electrode system, service entrance conductors serving the EV charger circuit
- 2
Final
Charger installed and operational, GFCI/AFCI protection verified where required, panel labeled
Applies to: Mechanical / HVAC Permit
- 1
Rough-In
Ductwork and gas piping installed, before walls closed — verify clearances and support
- 2
Final
Equipment operational, combustion air verified, gas pressure tested, thermostat functional
Applies to: Roofing Permit
- 1
Deck / Substrate
After tear-off — verify sheathing condition and replace damaged decking before proceeding
- 2
Final
Completed roof — verify ice and water shield, flashing, drip edge, ventilation, and nailing pattern
Applies to: Solar Panel Permit
- 1
Rough Electrical
Conduit runs, wire sizing, disconnect placement before energizing
- 2
Final / Structural
Panel mounting, racking attachment, roof penetration sealing, and electrical connections verified
Final inspection only: Fence Permit, Fire Alarm Permit, Fire Sprinkler Permit, Water Heater Permit
Re-inspection fees
Sources & verification
Verified against official sources. Last reviewed 2026-06-29.
Fees, timelines, and adopted codes are researched from each jurisdiction's published records — see how we verify. Requirements change and vary by project, so always confirm the current details with the West Jordan building department before you submit. PermitBase is an independent reference and is not affiliated with any government agency.