Skip to main content
PermitBase

Sign Permit (Zoning Certificate) in Unincorporated Campbell County, Wyoming

Campbell County has no separate 'sign permit' fee or application form — signage is regulated under Chapter 7 Zoning Regulations Section 40.25 (Signs) and is administered through the Zoning Certificate process (Chapter 7 Section 10.25), a Review Process 1 (administrative, no public hearing) approval. Table 10.10-1 explicitly lists 'Sign Permits (Section 40.25)' as a Review Process 1 action decided by the Applicable Director (Director of Public Works, Building Official, or Planner/Zoning Administrator).

Verified 2026-07-22 · Source

When you need this permit

  • Zoning Certification required prior to installing a sign (Chapter 7 § 10.25(2))
  • Every Use District Chart assigns a Sign Category (A, B, C, D, E, or F) to each permitted use; the applicable category governs sign type, area, and height (§ 40.25(1))
  • Sign Category A: wall-mounted and pedestal signs only, no internal illumination, no commercial messages permitted; max 4 sq. ft. for a detached-dwelling ID sign, 30 sq. ft. per sign face for a complex/subdivision ID sign
  • Sign Category B: wall-mounted, marquee, and pedestal signs; max 40 sq. ft. per sign face
  • Sign Categories C, D, and E: wall-mounted, marquee, pedestal, monument, and pole signs; area set by Table 40.25-1 based on the property's total linear road frontage (e.g., Category C at 100 ft frontage = 48 sq. ft.; Category E at 100 ft frontage = 94 sq. ft.)
  • Sign Category F: all sign types listed above; the largest area allowances in Table 40.25-1 (e.g., 108 sq. ft. at 100 ft frontage)
  • Height limits: pedestal signs ≤10 ft, monument signs ≤16 ft, pole signs ≤35 ft above average ground elevation; wall-mounted/marquee signs may not project above the roofline
  • Monument and pole signs must be set back at least 5 ft from all property lines; Off-Premise signs must be set back at least 10 ft from property lines and stay 20 linear ft clear of utility lines/structures
  • Off-Premise (billboard-type) signs are allowed only in Commercial, Industrial, A-L (Agricultural), and R-L (Rural Living) districts; a Conditional Use Permit is required if placed within 500 ft of a residential building, church, cemetery, or school; max 40 ft long x 14 ft high (560 sq. ft.) per face, plus limited embellishment extensions
  • Electronic Graphic Display Signs (EGDS) must hold each message a minimum of 6 seconds with no more than a 1-2 second animated transition, be set back 100 ft minimum from an adjacent residential district (150 ft orientation restriction), and maintain 2,000 ft separation from any other EGDS; audio and flashing/scrolling effects are prohibited
  • Prohibited devices include pennants, banners, and streamers (outside an approved Temporary Use Permit); strings/flashing/colored lights; twirlers, propellers, and inflatable signs; and any sign shaped/colored like a traffic sign or reading 'stop,' 'look,' or 'danger'
  • Damaged/deteriorated signs must be repaired within 60 days of notice (one 90-day extension available); nonconforming signs must be removed within 30 days, and sign copy/graphics removed within 90 days, of the associated business/use ceasing

Required documents

Check off what you have — your progress is saved on this device.

Not ready yet0 of 2 required documents checked.

This checker covers one permit. A full project usually triggers several — our paid checklist will assemble all of them, from $29

Fee schedule

Zoning Certificate (Sign Permit)Chapter 7 Zoning Regulations, Section 10.15(7)(a)(i): 'Zoning Certificate: No Fee.' Table 10.10-1 confirms Sign Permits are processed as a Review Process 1 Zoning Certificate action.
No fee
Conditional Use Permit (only if an off-premise sign is sited within 500 ft of a residential building, church, cemetery, or school)Chapter 7 Section 10.15(7)(a)(vii), triggered by § 40.25(9)(a)(ii)'s 500-ft proximity rule for off-premise signs
$200.00

Review timeline

Plan review
Not published — contact the department

How long did your Sign Permit (Zoning Certificate) permit actually take in Unincorporated Campbell County?

Anonymous — one question, no email. Answers are combined and only shown once at least 5 people have reported.

Inspection process

  1. 1

    Sign Compliance Verification

    The Applicable Director may verify an installed sign matches the approved Zoning Certificate (area, height, category, setback) per Chapter 7 § 10.20(4) Post-Approval Inspections

See the full Unincorporated Campbell County inspection guide — scheduling & re-inspection fees →

Tips

  • Campbell County publishes no distinct 'sign permit' fee — signage goes through the same no-fee Zoning Certificate (Review Process 1) used for other administrative approvals; confirm your use's assigned Sign Category (A-F) in the applicable Use District Chart before designing your sign.
  • Off-premise (billboard) signs are tightly restricted: allowed only in Commercial, Industrial, A-L, and R-L districts, and require a $200 Conditional Use Permit if within 500 ft of a home, church, cemetery, or school.
  • Electronic Graphic Display Signs cannot use flashing, scrolling, or animated effects beyond a 1-2 second message transition, and must sit at least 2,000 ft from any other electronic display sign in the county.

Frequently asked questions

Unincorporated Campbell County requires a sign permit (zoning certificate) for: Zoning Certification required prior to installing a sign (Chapter 7 § 10.25(2)); Every Use District Chart assigns a Sign Category (A, B, C, D, E, or F) to each permitted use; the applicable category governs sign type, area, and height (§ 40.25(1)); Sign Category A: wall-mounted and pedestal signs only, no internal illumination, no commercial messages permitted; max 4 sq. ft. for a detached-dwelling ID sign, 30 sq. ft. per sign face for a complex/subdivision ID sign; Sign Category B: wall-mounted, marquee, and pedestal signs; max 40 sq. ft. per sign face; Sign Categories C, D, and E: wall-mounted, marquee, pedestal, monument, and pole signs; area set by Table 40.25-1 based on the property's total linear road frontage (e.g., Category C at 100 ft frontage = 48 sq. ft.; Category E at 100 ft frontage = 94 sq. ft.); Sign Category F: all sign types listed above; the largest area allowances in Table 40.25-1 (e.g., 108 sq. ft. at 100 ft frontage); Height limits: pedestal signs ≤10 ft, monument signs ≤16 ft, pole signs ≤35 ft above average ground elevation; wall-mounted/marquee signs may not project above the roofline; Monument and pole signs must be set back at least 5 ft from all property lines; Off-Premise signs must be set back at least 10 ft from property lines and stay 20 linear ft clear of utility lines/structures; Off-Premise (billboard-type) signs are allowed only in Commercial, Industrial, A-L (Agricultural), and R-L (Rural Living) districts; a Conditional Use Permit is required if placed within 500 ft of a residential building, church, cemetery, or school; max 40 ft long x 14 ft high (560 sq. ft.) per face, plus limited embellishment extensions; Electronic Graphic Display Signs (EGDS) must hold each message a minimum of 6 seconds with no more than a 1-2 second animated transition, be set back 100 ft minimum from an adjacent residential district (150 ft orientation restriction), and maintain 2,000 ft separation from any other EGDS; audio and flashing/scrolling effects are prohibited; Prohibited devices include pennants, banners, and streamers (outside an approved Temporary Use Permit); strings/flashing/colored lights; twirlers, propellers, and inflatable signs; and any sign shaped/colored like a traffic sign or reading 'stop,' 'look,' or 'danger'; Damaged/deteriorated signs must be repaired within 60 days of notice (one 90-day extension available); nonconforming signs must be removed within 30 days, and sign copy/graphics removed within 90 days, of the associated business/use ceasing. If your project isn't listed, confirm with Campbell County Department of Public Works — Building, Planning & Zoning Division at (307) 682-1970 before starting work.

No. Signage is approved through the Zoning Certificate process (Chapter 7 Section 10.25), which Section 10.15(7)(a)(i) sets at 'No Fee.' A Conditional Use Permit ($200) is only required for an off-premise sign sited within 500 feet of a residential building, church, cemetery, or school.

Unincorporated Campbell County does not publish a plan-review timeline for this permit. Contact Campbell County Department of Public Works — Building, Planning & Zoning Division at (307) 682-1970 for current turnaround.

You'll need: Zoning Certificate Application; Site Plan or Sign Location Drawing. Depending on your project, Unincorporated Campbell County may also ask for: Master Sign Plan (if applicable). See the required-documents checklist on this page for details on each.

Unincorporated Campbell County requires 1 inspection(s) for a sign permit (zoning certificate), in order: Sign Compliance Verification. Schedule each through Campbell County Department of Public Works — Building, Planning & Zoning Division ((307) 682-1970).

Apply through Campbell County Department of Public Works — Building, Planning & Zoning Division at 500 S. Gillette Ave., Suite 1500, Gillette, WY 82716. Phone: (307) 682-1970, email: septic@campbellcountywy.gov (Small Wastewater System applications); planning@campbellcountywy.gov (Planning & Zoning); general Public Works (307) 685-8061. Office hours: Mon–Fri, 8:00 a.m.–5:00 p.m.. Official information: https://www.ccgov.net/286/Building-Division.

Unincorporated Campbell County, Wyoming has adopted: 2024 International Building Code (IBC) — including Appendices C and J, adopted by Campbell County Chapter 4 Rules Regulating Construction, Section 3 (Amended June 2026); 2024 International Residential Code (IRC) — including Appendices A, B, C and E, adopted Chapter 4 Section 4 (Amended June 2026); 2024 International Mechanical Code (IMC) — including Appendix A, adopted Chapter 4 Section 5; 2024 International Plumbing Code (IPC) — including Appendices A and B, adopted Chapter 4 Section 6 — NOTE: Campbell County uses the IPC, not the Uniform Plumbing Code; 2024 International Fuel Gas Code (IFGC) — all appendices, adopted Chapter 4 Section 7; 2024 International Fire Code (IFC), adopted Chapter 4 Section 8 (enforced by Campbell County Fire Department for Fire Code permits); 2024 International Existing Building Code (IEBC), adopted Chapter 4 Section 9; National Electrical Code (NFPA 70), 2026 Edition — including Informative Annex H, adopted Chapter 4 Section 10; Liquefied Petroleum Gas Code (NFPA 58), 2020 Edition, adopted Chapter 4 Section 11; Wyoming DEQ Water Quality Rules and Regulations Chapter 25 (Septic Tanks, Soil Absorption Systems, and Other Small Wastewater Systems) — adopted as Chapter 4 Appendix 1, administered by Campbell County under delegated authority from Wyoming DEQ (W.S. 35-11-304). Local amendments apply — see the Unincorporated Campbell County overview page for the full list.

Each use is assigned a Sign Category (A through F) in the applicable Chapter 7 Use District Chart. Categories C, D, E, and F use Table 40.25-1, which sets maximum sign area based on the property's total linear road frontage; Categories A and B have flat area caps (4-30 sq. ft. and 40 sq. ft. per sign face, respectively).

Sources & verification

Verified against official sources. Last reviewed 2026-07-22.

Fees, timelines, and adopted codes are researched from each jurisdiction's published records — see how we verify. Requirements change and vary by project, so always confirm the current details with the Unincorporated Campbell County building department before you submit. PermitBase is an independent reference and is not affiliated with any government agency.