Residential Building Permit (New Construction) in Akron, Colorado

Required for new construction of one- and two-family dwellings and townhomes (not more than three stories) in the Town of Akron. Reviewed under the 2009 IRC as locally adopted and amended (Town Code 10-3-1, 10-3-2), including Akron's specific Table R301.2(1) design criteria (20 psf ground snow load, 90 mph wind speed, Seismic Design Category C, 30-inch frost depth). Issued by the Town's Building Inspector.

Verified 2026-07-13 · Source

When you need this permit

  • Plans/work must comply with the 2009 IRC as locally adopted and amended, including Akron's Table R301.2(1) design criteria: 20 psf ground snow load, 90 mph wind speed (no topographic effects), Seismic Design Category C, 30-inch minimum frost line depth, Slight-to-Moderate termite exposure, 0 F winter design temperature, no ice shield underlayment required, Air Freezing Index 0-1000, Mean Annual Temp 47 F
  • Automatic residential fire sprinkler systems are NOT required for one- and two-family dwellings under Akron's local amendment to Section R313.2 (deleted); this requirement applies only to townhouses (Section R313.1, effective 2-3-2014)
  • Permit becomes invalid if work is not commenced within 180 days of issuance, or if suspended/abandoned for 180 days; standard permit validity is 12 months from issuance, extendable in limited circumstances (see localAmendments)
  • Fees are paid to the Town Clerk and deposited in the Town's General Fund per Town Code 10-1-1; building fees and use taxes are calculated based on construction cost and are due at the time the application is submitted (per the Town's live Building Department page) — there is no separate fixed dollar fee schedule to look up
  • A Certificate of Occupancy (CO) must be obtained before any building can be occupied (Town's live Building Department page, corroborated by Wayback snapshots of the same page dated 2020-08-13 and 2021-10-06)
  • All building permits require a plot plan showing placement of the structure, grades, elevations, sidewalks, curb and gutters, and other pertinent information (per the current application form and the live Building Department page)
  • If the work involves roofing, shingles must carry a National Wind Warranty of 89 mph sustained or 115 mph 3-second gust per the current application form; separately, the Town's live Building Department page states roofing must meet Ground Snow 20 / Roof Snow 30 loading, a minimum 110 mph wind shingle rating, and that ice-and-water-guard and drip-edge underlayment are NOT required by the Town (check with your insurer, as their requirements may differ) — both figures are cited as stated by their respective sources and have not been reconciled into a single number

Required documents

Check off what you have — your progress is saved on this device.

Not ready yet0 of 1 required documents checked.

This checker covers one permit. A full project usually triggers several — our paid checklist will assemble all of them, from $29

Fee schedule

General new-construction/building permit feeConfirmed on the Town's live Building Department page (townofakron.com/179/Building) and independently corroborated by Wayback snapshots of the same page dated 2020-08-13 and 2021-10-06; no separate published fee schedule exists anywhere on the Town's site or in Town Code Title 10.
Not a fixed figure — calculated based on construction cost (valuation-based), due at time of application submission
Manufactured/Mobile Home placement permit — base feeLive Building Department page (townofakron.com/179/Building), checked 2026-07-13: 'Fill out a building permit for the Town of Akron and pay the base pay of $24.60.' Applicant must also submit a Google Maps satellite image marking the placement location with the application. This is the only fixed dollar figure published anywhere on the Town's current site or Town Code; it applies specifically to manufactured/mobile home placement, not general new construction.
$24.60

Review timeline

Plan review
Not published — contact the department

How long did your Residential Building Permit (New Construction) permit actually take in Akron?

Anonymous — one question, no email. Answers are combined and only shown once at least 5 people have reported.

Inspection process

  1. 1

    Foundation

    Before concrete pour, per Akron's 30-inch minimum frost line depth (Table R301.2(1))

  2. 2

    Framing

    Structural framing complete before cover

  3. 3

    Final Inspection

    All work complete per approved plans and applicable codes; required for permanent power/occupancy

See the full Akron inspection guide — scheduling & re-inspection fees →

Tips

  • Akron's Table R301.2(1) design criteria (20 psf ground snow load, 90 mph wind speed, Seismic Design Category C, 30-inch frost depth) are set locally and differ materially from mountain-jurisdiction values elsewhere in this corpus — confirm your design professional is using Akron's specific figures, not a generic Colorado Front Range or mountain-town assumption.
  • The Town's adopted IRC edition (2009) is notably older than its adopted IBC edition (2018) — if your project spans both codes (e.g., a mixed-use or ambiguous-occupancy structure), confirm with the Building Inspector which edition/chapter governs.
  • The Town's website migrated from townofakron.colorado.gov to www.townofakron.com — old bookmarked colorado.gov links now redirect to the new homepage, but the Building Department page and current application PDF are live at townofakron.com/179/Building and townofakron.com/DocumentCenter/View/201 respectively (confirmed 2026-07-13); call Town Hall (970-345-2624, Monday-Thursday 7:30 AM-5:30 PM) to confirm project-specific fees, which are calculated from construction cost rather than published as a table.

Frequently asked questions

Akron requires a residential building permit (new construction) for: Plans/work must comply with the 2009 IRC as locally adopted and amended, including Akron's Table R301.2(1) design criteria: 20 psf ground snow load, 90 mph wind speed (no topographic effects), Seismic Design Category C, 30-inch minimum frost line depth, Slight-to-Moderate termite exposure, 0 F winter design temperature, no ice shield underlayment required, Air Freezing Index 0-1000, Mean Annual Temp 47 F; Automatic residential fire sprinkler systems are NOT required for one- and two-family dwellings under Akron's local amendment to Section R313.2 (deleted); this requirement applies only to townhouses (Section R313.1, effective 2-3-2014); Permit becomes invalid if work is not commenced within 180 days of issuance, or if suspended/abandoned for 180 days; standard permit validity is 12 months from issuance, extendable in limited circumstances (see localAmendments); Fees are paid to the Town Clerk and deposited in the Town's General Fund per Town Code 10-1-1; building fees and use taxes are calculated based on construction cost and are due at the time the application is submitted (per the Town's live Building Department page) — there is no separate fixed dollar fee schedule to look up; A Certificate of Occupancy (CO) must be obtained before any building can be occupied (Town's live Building Department page, corroborated by Wayback snapshots of the same page dated 2020-08-13 and 2021-10-06); All building permits require a plot plan showing placement of the structure, grades, elevations, sidewalks, curb and gutters, and other pertinent information (per the current application form and the live Building Department page); If the work involves roofing, shingles must carry a National Wind Warranty of 89 mph sustained or 115 mph 3-second gust per the current application form; separately, the Town's live Building Department page states roofing must meet Ground Snow 20 / Roof Snow 30 loading, a minimum 110 mph wind shingle rating, and that ice-and-water-guard and drip-edge underlayment are NOT required by the Town (check with your insurer, as their requirements may differ) — both figures are cited as stated by their respective sources and have not been reconciled into a single number. If your project isn't listed, confirm with Town of Akron — Office of the Building Inspector (Town Hall) at 970-345-2624 before starting work.

In Akron, the published General new-construction/building permit fee is: Not a fixed figure — calculated based on construction cost (valuation-based), due at time of application submission. Additional published fees: Manufactured/Mobile Home placement permit — base fee — $24.60. These are the jurisdiction's own published figures — see the fee schedule table and source citations on this page.

Akron does not publish a plan-review timeline for this permit. Contact Town of Akron — Office of the Building Inspector (Town Hall) at 970-345-2624 for current turnaround.

You'll need: Building Permit Application. See the required-documents checklist on this page for details on each.

Akron requires 3 inspection(s) for a residential building permit (new construction), in order: Foundation, Framing, Final Inspection. Schedule each through Town of Akron — Office of the Building Inspector (Town Hall) (970-345-2624).

Apply through Town of Akron — Office of the Building Inspector (Town Hall) at 250 Main Ave, Akron, CO 80720. Phone: 970-345-2624, email: deputyclerk@townofakron.com. Office hours: Monday - Thursday, 7:30 AM - 5:30 PM; closed Fridays. Fax: 970-345-2617. Per Town Code 10-1-1, the Building Inspector is appointed by the Board of Trustees at its first regular meeting following each biennial election and serves as chief enforcement officer for all Title 10 building regulations (except fire prevention code); there is no separate physical 'Building Department' office distinct from Town Hall in this small Eastern Plains town (2020 Census population 1,757).. Official information: https://www.townofakron.com/179/Building.

The Town of Akron's Building Inspector, appointed by the Board of Trustees per Town Code 10-1-1, issues and enforces building permits within Akron town limits under Title 10 of the Town Code. There is no separate physical Building Department office distinct from Town Hall.

No. Akron's local amendment to the 2009 IRC deletes Section R313.2 (One- and Two-Family Dwellings Automatic Fire Systems), so single-family and duplex homes are not required to install automatic fire sprinklers. Only townhouses are required to have them, per Section R313.1 as locally modified, effective February 3, 2014.