Firestone building inspections
Inspection sequence, scheduling, and re-inspection fees for building permits in Firestone, Colorado.
Reviewed 2026-07-06 · Source
How to schedule
Inspections are requested through the building department below.
- Address
- 9950 Park Avenue, Firestone, CO 80504
- Phone
- 303-833-3291
- Office hours
- Monday through Friday, 8 a.m. to 5 p.m. (Town Hall hours). SAFEbuilt Colorado's local office is at 11409 Business Park Circle, Suite 350, Firestone, CO 80504, phone 303-774-1388, per SAFEbuilt's own site. Firestone-specific SAFEbuilt inspection contact: firestone-building@safebuilt.com / 303-774-0454, and Building Official Tim Moroney, tmoroney@safebuilt.com / 970-545-3555. That staffing detail comes from a SAFEbuilt contact listing rather than a live staff directory, so confirm current staffing with the Town before relying on a named contact.
- Website
- Official site
Inspection sequence
Applies to: Commercial Building Permit (New Construction / Additions)
- 1
Footing/Foundation
Before concrete pour; commercial projects may optionally start under a standalone $2,000 Footing/Foundation Permit ahead of full permit issuance
- 2
Framing/Structural
Structural framing complete before cover, per approved stamped plans
- 3
Rough Electrical/Plumbing/Mechanical
Trade rough-ins before concealment; complex electrical/mechanical systems may additionally require a registered design professional's observation per Ordinance 1029 Sections 1704.7/1704.8
- 4
Fire District Inspections
Frederick-Firestone Fire Protection District performs its own inspections under its separate submittal/approval
- 5
Final Inspection / Certificate of Occupancy
All work complete per approved plans; performed by SAFEbuilt Colorado under contract to the Town. A Temporary CO is available for $750 ($400 refundable if the final CO issues before TCO expiration)
Applies to: Commercial Tenant Finish (Tenant Improvement) Permit
- 1
Rough Electrical/Plumbing/Mechanical
Trade rough-ins before concealment, per approved stamped plans
- 2
Framing (if structural scope)
New walls/structural elements before cover, when the TI includes framing or structural work
- 3
Fire District Inspections
Frederick-Firestone Fire Protection District performs its own inspections under its separate submittal/approval
- 4
Final Inspection / Certificate of Occupancy
All work complete per approved plans; performed by SAFEbuilt Colorado under contract to the Town. A Temporary CO is available for $750 ($400 refundable if the final CO issues before TCO expiration)
Applies to: Residential Addition / Remodel Permit
- 1
Foundation (if new footings)
Before concrete pour; crawlspace/basement foundation detail per the Town's Building Guide (steel anchor bolts, rebar, vapor barrier)
- 2
Framing
Framing and connection to existing structure
- 3
Rough Electrical/Plumbing/Mechanical
Trade rough-ins before concealment
- 4
Final Inspection
All work complete per approved plans
Applies to: Residential Building Permit (New Construction)
- 1
Foundation/Footing
Before concrete pour
- 2
Framing
Structural framing complete before cover
- 3
Rough Electrical/Plumbing/Mechanical
Trade rough-ins before concealment; complex electrical/mechanical systems may additionally require a registered design professional's Electrical/Mechanical Observation per Ordinance 1029 Sections 1704.7/1704.8 (health-care, >1000V, or hazardous-location scope)
- 4
Final Inspection
All work complete per approved plans and applicable codes; performed by SAFEbuilt Colorado under contract to the Town
Applies to: Electrical Permit
- 1
Rough Electrical
Wiring and panel installed before concealment
- 2
Final Inspection
Devices installed, panel labeled, system energized; performed by SAFEbuilt Colorado
Applies to: Fire Sprinkler and Fire Alarm System Permit
- 1
Fire District Plan Review
FFFPD reviews stamped Civil/Architectural/MEP drawings and fire safety system shop drawings under the currently adopted International Fire Code and NFPA Standards; accepted drawings are stamped and returned, and must be printed and kept on-site during construction
- 2
Final Inspection
On-site inspection of the installed fire alarm/sprinkler system by FFFPD; failed inspections are billed at the $100.00/hour rate, two-hour minimum
Applies to: Mechanical / HVAC Permit
- 1
Rough-In / Equipment
Equipment installation and ductwork before concealment
- 2
Final Inspection
Equipment operational; combustion air and venting verified; performed by SAFEbuilt Colorado
Applies to: Plumbing Permit
- 1
Rough Plumbing
Before concealment — pipe slope, materials, cleanouts
- 2
Final Inspection
Fixtures connected, no leaks, proper venting verified; performed by SAFEbuilt Colorado
Applies to: Roofing Permit (Reroof)
- 1
Mid-Roof Inspection
Required when no more than 25% of the roof is complete; verifies ice & water shield installed 24 inches inside the exterior wall line, drip edge fastened at minimum 12-inch on-center with proper overlap, and underlayment sequencing at eaves/rakes
- 2
Final Roof Inspection
Completed roof covering verified against approved plans and applicable code; performed by SAFEbuilt Colorado
Applies to: Solar PV Permit
- 1
Rough Electrical
Conduit runs, wire sizing, and disconnect placement before cover
- 2
Final Inspection
Racking, roof penetrations, and electrical connections verified; performed by SAFEbuilt Colorado
Re-inspection fees
Sources & verification
Key facts verified against official sources. Last reviewed 2026-07-06.
Fee schedules
Applications & forms
Checklists & handouts
Codes & ordinances
Department & other records
Fees, timelines, and adopted codes are researched from each jurisdiction's published records — see how we verify. Requirements change and vary by project, so always confirm the current details with the Firestone building department before you submit. PermitBase is an independent reference and is not affiliated with any government agency.
Firestone building permits
Get alerts for Firestone
We'll email you when Firestone's fees, documents, or codes change — not often.
We only use your email to send permit updates. No spam, unsubscribe anytime. Privacy.