EV Charger / Energy Storage System (ESS) Permit — Firestone, Colorado · Requirements sheet
Verified 2026-07-20 · Source: https://www.firestoneco.gov/DocumentCenter/View/11616/ToF-EV-and-ESS-Requirements
PermitBase is an independent reference and is not affiliated with any government agency. Requirements change and vary by project — confirm current details with the building department before you submit.
EV Charger / Energy Storage System (ESS) Permit in Firestone, Colorado
Firestone publishes a dedicated 'Firestone Single Family EV Car Charger and/or Energy Storage System' requirements guide (Rev 3.26.2024), distinct from its general Building Guides. New residential EV charging systems and/or energy storage systems use an 'RES inspection type' for all inspections, with specific plan-review submittal items, a 2023-code local amendment requiring a heat detector interconnected to the home's smoke detector system when an attached garage has an EV charger (per NFPA 70 Article 625), and detailed ESS placement/energy-rating rules (IRC Section R327, locally amended). Billed under the same area-based Residential Electrical Permit fee table documented in the electrical-permit entry — no distinct EV/ESS fee line was found on the Fee Schedule.
Verified 2026-07-20 · Source
When you need this permit
- Submit for plan review: (1) an electrical load calculation for the existing electrical panel, (2) specification documentation for the equipment to be installed, (3) a floor plan showing the location of the proposed equipment and the interconnected heat detector, and (4) a wiring diagram indicating point of connection, overcurrent protection, and wiring sizes/methods
- Firestone 2023 Code Amendment to IRC R314.2.3: when an attached garage has an EV Power Transfer System car charger installed per NFPA 70 Article 625, a heat detector shall be wired to the home's smoke detector system
- ESS-specific rules (IRC Section R327, as locally amended): ESS must be listed/labeled per UL 9540 (exempt if listed for residential use and under 1 kWh); individual units maximum 20 kWh; aggregate ratings capped at 40 kWh in utility closets/basements/storage, 80 kWh in garages/exterior walls/outdoors on the ground; minimum 3-foot separation between individual units; specific allowed locations (detached garages/accessory structures, attached garages on exterior walls only, or outdoors 3+ feet from doors/windows) with ESS prohibited in sleeping rooms or closets/spaces opening into sleeping rooms
- Garage walls/ceilings require minimum 5/8-inch Type X gypsum board per Firestone's amended IRC Table R302.6 dwelling-garage separation table
- Firestone-reviewed, stamped plans (printed from the online portal) and the permit card MUST be on-site for every required inspection — no inspection will be made without these
- A document on company letterhead, signed by the master electrician, confirming all lugs and terminals were torqued to manufacturer specifications is required at inspection
Required documents
Check off what you have — your progress is saved on this device.
Not ready yet — 0 of 2 required documents checked.
This checker covers one permit. A full project usually triggers several — our paid checklist will assemble all of them, from $29 →
Fee schedule
Review timeline
Inspection process
- 1
RES Inspection (single combined inspection type for EV/ESS)
Confirms type of EV charger, amperage, wire/conduit size and location per approved documentation; minimum 5/8 Type X drywall throughout garage walls/ceilings; heat detector interconnected with smoke detectors; added load does not overload the existing panel; master-electrician torque-compliance letter on file
See the full Firestone inspection guide — scheduling & re-inspection fees →
Tips
- Firestone treats EV chargers and energy storage systems as the same category — 'Both EV And ESS are Energy storage' per the Town's own guide — and both use the single 'RES inspection type.'
- Don't skip the heat-detector interconnection requirement: it applies specifically when an EV Power Transfer System charger is installed in an attached garage, per Firestone's 2023 IRC R314.2.3 amendment.
- ESS units are capped at 80 kWh aggregate in garages/exterior walls/outdoors and 40 kWh in utility closets/basements — confirm your battery system's rating against these locally amended thresholds before submitting plans.
- No EV/ESS-specific fee line exists — budget using the standard area-based Residential Electrical Permit fee table.
Frequently asked questions
Sources & verification
Verified against official sources. Last reviewed 2026-07-20.
Fees, timelines, and adopted codes are researched from each jurisdiction's published records — see how we verify. Requirements change and vary by project, so always confirm the current details with the Firestone building department before you submit. PermitBase is an independent reference and is not affiliated with any government agency.
Other permits in Firestone
EV Charger / Energy Storage System (ESS) Permit in other cities
Compare ev charger / energy storage system (ess) permit fees across Colorado →
Look up this fee in a different city →
Related guides
Now live
Build your Firestone project checklist
Describe your project once and get every permit, document, and fee it triggers in Firestone — in one checklist. Sign up and pay once to generate it, or go unlimited with Pro.
Get started →