Automatic Fire Sprinkler System Permit in Tremonton, Utah

Required for installation of automatic fire sprinkler systems in Tremonton. Tremonton City's own Fire Department page (tremontoncity.gov/services/firedept/) and its official Building & Solar Permit Requirements page do not publish a local fire-sprinkler plan review process or fee — the City's Consolidated Fees and Fines Schedule (Resolution No. 25-42) contains no fire-related fee line item anywhere in its full text. Fire sprinkler plans for Tremonton projects are therefore submitted to the Utah State Fire Marshal's Office (Sandy, UT), which runs the statewide Automatic Fire Sprinkler Plan Submittal process used by jurisdictions without their own local fire-plan-review authority. Tremonton's own commercial-building-permit submittal checklist separately lists an optional 'Fire Sprinkler Plan' document ('required if applicable'), consistent with this being routed as a companion submittal alongside the standard Building Permit rather than a City-run process.

Reviewed 2026-07-22 · Source

When you need this permit

  • Automatic fire sprinkler system design, alteration, or new installation subject to the adopted Fire Code (Tremonton has adopted the 2021 International Fire Code per its Building Criteria document)
  • Water supply analysis (static pressure, residual pressure, flow) provided per Utah Administrative Rule R710-4-5(A)(B)(C), sourced from contract specifications, a water supply analysis, the water purveyor, or a flow test
  • Plans, hydraulic calculations, and material submittals prepared/stamped by a licensed fire sprinkler contractor
  • Plan review fee paid to the Utah State Fire Marshal's Office before plan review is released

Required documents

Check off what you have — your progress is saved on this device.

Not ready yet0 of 4 required documents checked.

This checker covers one permit. A full project usually triggers several — our paid checklist will assemble all of them, from $29

Fee schedule

Fire Sprinkler Plan Review FeeUtah State Fire Marshal's Office Automatic Fire Sprinkler Plan Submittal Form: 'SQUARE FEET x .022 = $______. Note: Minimum fee is $75.' Fees must be paid before plan review will be released. No separate or additional fire-sprinkler fee is published in Tremonton City's own Consolidated Fees and Fines Schedule (Resolution No. 25-42) — a full-text review found no 'fire' line item in that document.
$0.022 per square foot of review scope, $75.00 minimum

Review timeline

Plan review
Not published — contact the department

How long did your Automatic Fire Sprinkler System Permit permit actually take in Tremonton?

Anonymous — one question, no email. Answers are combined and only shown once at least 5 people have reported.

Inspection process

  1. 1

    Fire Sprinkler System Inspection

    Physical installation inspection is expected to be scheduled through Tremonton's Building Department at (435) 257-9500, the same contact used for all other Building Permit inspections in the City — Tremonton's own site does not separately document a fire-sprinkler-specific inspection procedure distinct from its general Building Inspection process.

See the full Tremonton inspection guide — scheduling & re-inspection fees →

Tips

  • Tremonton has no local fire marshal plan-review process or fee published on its own site — fire sprinkler plans are submitted directly to the Utah State Fire Marshal's Office (planreviews@utah.gov, (801) 256-2390), not to Tremonton City Hall.
  • The $0.022/sq ft plan review fee (with a $75 minimum) must be paid before the State Fire Marshal's Office releases the plan review.
  • Tremonton's own commercial-building-permit checklist lists a 'Fire Sprinkler Plan' as an optional document 'required if applicable' — confirm with the Tremonton Building Department ((435) 564-0897) how this companion submittal is coordinated with the City's own commercial plan review before applying.

Frequently asked questions

Tremonton requires an automatic fire sprinkler system permit for: Automatic fire sprinkler system design, alteration, or new installation subject to the adopted Fire Code (Tremonton has adopted the 2021 International Fire Code per its Building Criteria document); Water supply analysis (static pressure, residual pressure, flow) provided per Utah Administrative Rule R710-4-5(A)(B)(C), sourced from contract specifications, a water supply analysis, the water purveyor, or a flow test; Plans, hydraulic calculations, and material submittals prepared/stamped by a licensed fire sprinkler contractor; Plan review fee paid to the Utah State Fire Marshal's Office before plan review is released. If your project isn't listed, confirm with Tremonton City Building Department (Community Development) at (801) 564-0897 before starting work.

In Tremonton, the published Fire Sprinkler Plan Review Fee is: $0.022 per square foot of review scope, $75.00 minimum. These are the jurisdiction's own published figures — see the fee schedule table and source citations on this page.

Tremonton does not publish a plan-review timeline for this permit. Contact Tremonton City Building Department (Community Development) at (801) 564-0897 for current turnaround.

You'll need: Automatic Fire Sprinkler Plan Submittal Form; Automatic Sprinkler Drawings; Hydraulic Calculations; Water Supply Analysis. Depending on your project, Tremonton may also ask for: Material Submittals; Seismic Calculations. See the required-documents checklist on this page for details on each.

Tremonton requires 1 inspection(s) for an automatic fire sprinkler system permit, in order: Fire Sprinkler System Inspection. Schedule each through Tremonton City Building Department (Community Development) ((801) 564-0897).

Tremonton City does not publish its own fire-sprinkler plan review process or fee. Fire sprinkler plans are submitted to the Utah State Fire Marshal's Office (410 West 9800 South, 3rd Floor, Sandy, UT 84070; planreviews@utah.gov; (801) 256-2390) using its statewide Automatic Fire Sprinkler Plan Submittal Form, at a fee of $0.022 per square foot with a $75.00 minimum.

Tremonton, Utah has adopted: 2024 International Building Code (IBC), including Appendices C and J — CURRENT statewide as of 7/1/2026 per Utah Code § 15A-2-103(1)(a); supersedes the 2021 edition previously listed here. Tremonton's own Building Criteria PDF (live-checked 2026-07-16, still hosted at the same URL, last modified April 2024) still lists '2021 International Building Code' and has not been updated to reflect the 7/1/2026 statewide edition change — the statute controls over the lagging city document.; 2021 International Residential Code (IRC) — REMAINS CURRENT; Utah Code § 15A-2-103(1)(b) did NOT change this edition in the 7/1/2026 statewide amendment. Consistent with Tremonton's own Building Criteria document.; Appendix AQ of the 2021 IRC — statewide per Utah Code § 15A-2-103(1)(c); not itemized in Tremonton's own Building Criteria document, added here per statute.; 2021 International Fire Code (IFC) — per Tremonton's own Building Criteria document; NOTE: the IFC is adopted under Utah Code Title 15A Chapter 5, not § 15A-2-103 (which governs the IBC/IRC/IPC/IMC/IFGC/IECC/IEBC/NEC/residential-ISPSC/MBI editions listed in this array) — § 15A-2-103 does not itself adopt or list an IFC edition, so this entry is unaffected by the 7/1/2026 § 15A-2-103 amendment.; 2024 International Fuel Gas Code (IFGC) — CURRENT statewide as of 7/1/2026 per Utah Code § 15A-2-103(1)(f); supersedes the 2021 edition. Tremonton's own Building Criteria document (live-checked 2026-07-16) still lists '2021 International Fuel Gas Code' and has not been updated.; 2024 International Mechanical Code (IMC) — CURRENT statewide as of 7/1/2026 per Utah Code § 15A-2-103(1)(e); supersedes the 2021 edition. Tremonton's own Building Criteria document (live-checked 2026-07-16) still lists '2021 International Mechanical Code' and has not been updated.; 2024 International Plumbing Code (IPC) — CURRENT statewide as of 7/1/2026 per Utah Code § 15A-2-103(1)(d); supersedes the 2021 edition. Tremonton's own Building Criteria document (live-checked 2026-07-16) still lists '2021 International Plumbing Code' and has not been updated.; 2021 International Property Maintenance Code (IPMC) — per the same document; not adopted or superseded by § 15A-2-103, which does not list an IPMC edition, so this entry is unaffected by the 7/1/2026 amendment; 2024 International Energy Conservation Code (IECC), single unsplit statewide edition — CURRENT statewide as of 7/1/2026 per Utah Code § 15A-2-103(1)(h); supersedes the 2021 edition. Tremonton's own Building Criteria document (live-checked 2026-07-16) still lists '2021 Energy Conservation Code' and has not been updated.; 2023 National Electrical Code (NEC) — CURRENT statewide per Utah Code § 15A-2-103(1)(g); UNCHANGED by the 7/1/2026 amendment (2023 has been the statewide NEC edition since before this cycle). Tremonton's own Building Criteria document (live-checked 2026-07-16, still hosted at the same URL) lists '2020 National Electrical Code,' which is NOT a valid statewide-adopted edition and has not been corrected by the City — the statute controls. Confirm the currently enforced NEC edition directly with the Building Department before relying on the City's own document for a live project.; 1997 Edition of the Uniform Code for the Abatement of Dangerous Buildings — per the same document; not governed by § 15A-2-103; 2017 Edition of the ICC/ANSI A117.1 Standard for Accessibility — per the same document; not governed by § 15A-2-103; 2024 International Existing Building Code (IEBC) — statewide per Utah Code § 15A-2-103(1)(i); not itemized in Tremonton's own Building Criteria document, added here per statute since the City's own materials omit it.; Residential provisions of the 2024 International Swimming Pool and Spa Code (ISPSC) — statewide per Utah Code § 15A-2-103(1)(n); not itemized in Tremonton's own Building Criteria document, added here per statute since the City's own materials omit it.; MBI 1200 and MBI 1205 (manufactured/modular construction standards) — statewide per Utah Code § 15A-2-103(1)(o); not itemized in Tremonton's own Building Criteria document, added here per statute since the City's own materials omit it.; NOTE (2026-07-16 re-verification): Utah Code § 15A-2-103, version effective 7/1/2026 (superseded 1/1/2027), took effect 15 days before this re-verification. IBC/IPC/IMC/IFGC/IECC/IEBC/residential ISPSC are now 2024 statewide; IRC (2021) and NEC (2023) did NOT change from the prior cycle. Tremonton's own Building Criteria PDF (tremontoncity.gov/wp-content/uploads/2024/04/BUILDING-DESIGN-CRITERIA.pdf) was re-fetched live 2026-07-16 and still lists 2021 IBC/IFGC/IMC/IPC/'2021 Energy Conservation Code' and an outright incorrect '2020 National Electrical Code' — none of these have been updated by the City to reflect the statewide 7/1/2026 transition or the pre-existing 2023 NEC requirement. The statute is cited directly as governing throughout; the City's lagging document is preserved above as recorded history, not deleted.. Local amendments apply — see the Tremonton overview page for the full list.

Sources & verification

Key facts verified against official sources. Last reviewed 2026-07-22.

Fees, timelines, and adopted codes are researched from each jurisdiction's published records — see how we verify. Requirements change and vary by project, so always confirm the current details with the Tremonton building department before you submit. PermitBase is an independent reference and is not affiliated with any government agency.