Tremonton building permits
VerifiedDepartment contacts, adopted codes, permit types, fees, and gotchas for Tremonton, Utah.
Last verified 2026-07-08 · Source · Embed this page’s badge · Version history
Building department
- Address
- 102 South Tremont Street, Tremonton, UT 84337
- Phone
- (801) 564-0897
- Office hours
- Monday–Friday 9:00 AM – 5:00 PM (per Tremonton City Contact Us page); general offices closed Saturday–Sunday
- Website
- Official site
- Permit portal
- Apply online at Tremonton's portal
Inspection guide
See how inspections work in Tremonton — sequence, scheduling & re-inspection fees.
Codes adopted
Utah adopts construction codes statewide under Utah Code Title 15A (State Construction and Fire Codes Act), enforced by every jurisdiction. Chapter 4 of Title 15A codifies Legislature-enacted amendments for specific named jurisdictions (e.g., Park City, Salt Lake City, Sandy City) as part of the state construction code. Through June 30, 2026, the editions in force under Utah Code § 15A-2-103 are the 2021 IBC (with Appendices C and J), 2021 IRC, 2021 IPC, 2021 IMC, 2021 IFGC, 2021 IECC, 2021 IEBC, and 2021 ISPSC (residential provisions), together with the 2023 NEC. Effective July 1, 2026, § 15A-2-103 adopts the 2024 editions of the IBC, IPC, IMC, IFGC, IECC, IEBC, and ISPSC; the IRC remains the 2021 edition and the NEC remains the 2023 edition. Note: residential energy requirements are modified by statewide amendments, and several Utah jurisdictions document their residential energy provisions at the 2015 IECC level rather than the adopted IECC year — confirm the applicable residential energy code with your local jurisdiction. Always confirm the edition in force with your local jurisdiction.
- 2024 International Building Code (IBC), including Appendices C and J — CURRENT statewide as of 7/1/2026 per Utah Code § 15A-2-103(1)(a); supersedes the 2021 edition previously listed here. Tremonton's own Building Criteria PDF (live-checked 2026-07-16, still hosted at the same URL, last modified April 2024) still lists '2021 International Building Code' and has not been updated to reflect the 7/1/2026 statewide edition change — the statute controls over the lagging city document.
- 2021 International Residential Code (IRC) — REMAINS CURRENT; Utah Code § 15A-2-103(1)(b) did NOT change this edition in the 7/1/2026 statewide amendment. Consistent with Tremonton's own Building Criteria document.
- Appendix AQ of the 2021 IRC — statewide per Utah Code § 15A-2-103(1)(c); not itemized in Tremonton's own Building Criteria document, added here per statute.
- 2021 International Fire Code (IFC) — per Tremonton's own Building Criteria document; NOTE: the IFC is adopted under Utah Code Title 15A Chapter 5, not § 15A-2-103 (which governs the IBC/IRC/IPC/IMC/IFGC/IECC/IEBC/NEC/residential-ISPSC/MBI editions listed in this array) — § 15A-2-103 does not itself adopt or list an IFC edition, so this entry is unaffected by the 7/1/2026 § 15A-2-103 amendment.
- 2024 International Fuel Gas Code (IFGC) — CURRENT statewide as of 7/1/2026 per Utah Code § 15A-2-103(1)(f); supersedes the 2021 edition. Tremonton's own Building Criteria document (live-checked 2026-07-16) still lists '2021 International Fuel Gas Code' and has not been updated.
- 2024 International Mechanical Code (IMC) — CURRENT statewide as of 7/1/2026 per Utah Code § 15A-2-103(1)(e); supersedes the 2021 edition. Tremonton's own Building Criteria document (live-checked 2026-07-16) still lists '2021 International Mechanical Code' and has not been updated.
- 2024 International Plumbing Code (IPC) — CURRENT statewide as of 7/1/2026 per Utah Code § 15A-2-103(1)(d); supersedes the 2021 edition. Tremonton's own Building Criteria document (live-checked 2026-07-16) still lists '2021 International Plumbing Code' and has not been updated.
- 2021 International Property Maintenance Code (IPMC) — per the same document; not adopted or superseded by § 15A-2-103, which does not list an IPMC edition, so this entry is unaffected by the 7/1/2026 amendment
- 2024 International Energy Conservation Code (IECC), single unsplit statewide edition — CURRENT statewide as of 7/1/2026 per Utah Code § 15A-2-103(1)(h); supersedes the 2021 edition. Tremonton's own Building Criteria document (live-checked 2026-07-16) still lists '2021 Energy Conservation Code' and has not been updated.
- 2023 National Electrical Code (NEC) — CURRENT statewide per Utah Code § 15A-2-103(1)(g); UNCHANGED by the 7/1/2026 amendment (2023 has been the statewide NEC edition since before this cycle). Tremonton's own Building Criteria document (live-checked 2026-07-16, still hosted at the same URL) lists '2020 National Electrical Code,' which is NOT a valid statewide-adopted edition and has not been corrected by the City — the statute controls. Confirm the currently enforced NEC edition directly with the Building Department before relying on the City's own document for a live project.
- 1997 Edition of the Uniform Code for the Abatement of Dangerous Buildings — per the same document; not governed by § 15A-2-103
- 2017 Edition of the ICC/ANSI A117.1 Standard for Accessibility — per the same document; not governed by § 15A-2-103
- 2024 International Existing Building Code (IEBC) — statewide per Utah Code § 15A-2-103(1)(i); not itemized in Tremonton's own Building Criteria document, added here per statute since the City's own materials omit it.
- Residential provisions of the 2024 International Swimming Pool and Spa Code (ISPSC) — statewide per Utah Code § 15A-2-103(1)(n); not itemized in Tremonton's own Building Criteria document, added here per statute since the City's own materials omit it.
- MBI 1200 and MBI 1205 (manufactured/modular construction standards) — statewide per Utah Code § 15A-2-103(1)(o); not itemized in Tremonton's own Building Criteria document, added here per statute since the City's own materials omit it.
- NOTE (2026-07-16 re-verification): Utah Code § 15A-2-103, version effective 7/1/2026 (superseded 1/1/2027), took effect 15 days before this re-verification. IBC/IPC/IMC/IFGC/IECC/IEBC/residential ISPSC are now 2024 statewide; IRC (2021) and NEC (2023) did NOT change from the prior cycle. Tremonton's own Building Criteria PDF (tremontoncity.gov/wp-content/uploads/2024/04/BUILDING-DESIGN-CRITERIA.pdf) was re-fetched live 2026-07-16 and still lists 2021 IBC/IFGC/IMC/IPC/'2021 Energy Conservation Code' and an outright incorrect '2020 National Electrical Code' — none of these have been updated by the City to reflect the statewide 7/1/2026 transition or the pre-existing 2023 NEC requirement. The statute is cited directly as governing throughout; the City's lagging document is preserved above as recorded history, not deleted.
Permit types & fees
Residential Building Permit
Required for new single-family dwelling construction, residential outbuildings, and any work regulated by the adopted 2024 IBC / 2021 IRC in Tremonton (2024 IBC current per Utah Code § 15A-2-103(1)(a) effective 7/1/2026; IRC remains 2021 per § 15A-2-103(1)(b)). Permit fee is valuation-based (1% of Building Valuation per the ICC Building Valuation Table) rather than a flat fee, per the City's official Consolidated Fees and Fines Schedule (Resolution No. 25-42, effective August 26, 2025).
Commercial / Industrial Building Permit
Required for new commercial and industrial construction in Tremonton. Requires professionally drawn plans wet-stamped by a State of Utah licensed Engineer or Architect. Uses the same valuation-based fee structure as residential but with a substantially higher plan review percentage.
Solar Panel (PV) Permit
Required for residential and commercial rooftop or ground-mounted solar photovoltaic installations in Tremonton. The City publishes a dedicated Solar Permit Requirements checklist distinct from its standard residential/commercial submittal lists.
Re-Roofing Permit
Required for roof replacement/re-roofing in Tremonton. The City publishes a distinct flat fee for re-roofing, separate from its general valuation-based building permit fee.
Water Heater / Furnace / Electric Meter Permit (Standalone Trade)
Required for standalone water heater, furnace, or electric meter installation/replacement in Tremonton, each billed as a distinct flat Miscellaneous Building Inspection Service fee.
Manufactured Home / Mobile Home Permit
Required for placement of manufactured or mobile homes in Tremonton. Manufactured/Modular Homes must comply with the Residential Architectural Standards in the City's Supplementary Regulations, per Tremonton City Code § 1.28.035(B)(5)-(6).
Commercial Tenant Improvement / Tenant Finish Permit
Tremonton does not publish a separate tenant-improvement fee category. The City's Consolidated Fees and Fines Schedule (Resolution No. 25-42, effective 08/26/2025), Sections 3.3-3.4, bills all 'Industrial, Institutional, Commercial, & Governmental' work -- new construction, additions, and interior tenant-improvement/remodel projects alike -- under the same uniform structure: a 1%-of-Building-Valuation Permit Fee, a 1%-of-Permit-Fee State Fee, and a 65%-of-(Permit Fee + State Fee) Plan Review Fee (versus the 35% residential rate), with no separate tenant-improvement or commercial-remodel line item anywhere in the schedule. This is confirmed by direct read of the full Section 3.3/3.4 fee tables, which list only 'Permit Fee' and 'State Fee' (3.3) and 'Plan Review Fee' (3.4) rows -- no tenant-improvement or remodel sub-category exists on the commercial side, in contrast to Section 3.1's residential-only 'Small Scale Remodel or Construction' reduced-rate carve-outs (e.g., $60.00 electrical-only inspection).
Sign Permit
Required in Tremonton to erect, raise, move, place, reconstruct, extend, enlarge, alter, replace, or change the text of any sign, per Tremonton City Code Chapter 1.27 (Sign Permit). The flat Sign Permit fee is $50.00 per the city's Consolidated Fees & Fines Schedule. A Sign Permit may be submitted concurrently with a Building Permit, and it expires one year after approval unless a Building Permit, Business License, or other required permit is obtained.
EV Charger / EVSE Permit
Tremonton City does not publish a distinct EV charger / EVSE fee line item. The city's Consolidated Fees and Fines Schedule (Resolution No. 25-42) prices a 'Small Scale Remodel or Construction — Electrical Inspection Only' category at a flat $60.00, which is the fee category an EV charger circuit installation would most plausibly fall under, but the city does not explicitly name EV chargers, EVSE, or electric vehicle charging in any published fee document.
Automatic Fire Sprinkler System Permit
Required for installation of automatic fire sprinkler systems in Tremonton. Tremonton City's own Fire Department page (tremontoncity.gov/services/firedept/) and its official Building & Solar Permit Requirements page do not publish a local fire-sprinkler plan review process or fee — the City's Consolidated Fees and Fines Schedule (Resolution No. 25-42) contains no fire-related fee line item anywhere in its full text. Fire sprinkler plans for Tremonton projects are therefore submitted to the Utah State Fire Marshal's Office (Sandy, UT), which runs the statewide Automatic Fire Sprinkler Plan Submittal process used by jurisdictions without their own local fire-plan-review authority. Tremonton's own commercial-building-permit submittal checklist separately lists an optional 'Fire Sprinkler Plan' document ('required if applicable'), consistent with this being routed as a companion submittal alongside the standard Building Permit rather than a City-run process.
Fire Alarm System Permit
Required for installation of fire alarm systems in Tremonton. As with fire sprinkler systems, Tremonton City's own Fire Department and Building & Solar Permit Requirements pages do not publish a local fire-alarm plan review process or fee, and no 'fire' line item appears anywhere in the City's Consolidated Fees and Fines Schedule (Resolution No. 25-42). Fire alarm plans for Tremonton projects are therefore submitted to the Utah State Fire Marshal's Office (Sandy, UT) using its separate, dedicated Fire Alarm Plan Review Submittal Form — a distinct form and checklist from the Automatic Fire Sprinkler Plan Submittal Form, indicating the State Fire Marshal's Office organizes fire alarm and fire sprinkler plan review as two separate submittal processes rather than one combined process.
Change of Use / Change of Occupancy Permit
Tremonton does not publish a distinct 'change of use' permit type separate from its standard Building Permit. Tremonton City Code § 1.28.010 (Permit Required) states directly: 'UCA 10-9a-802(b) requires a Building Permit be issued to construct, enlarge, alter, repair, move, demolish, or change the occupancy of a building or structure...' A change of use/occupancy is therefore processed as a standard Building Permit application under Chapter 1.28, culminating in a Certificate of Occupancy issued by the Building Official under § 1.28.050 once the structure is confirmed compliant with the adopted Building Code, City Ordinances, and any conditions of a prior Site Plan Permit or Conditional Use Permit. The City's Consolidated Fees and Fines Schedule (Resolution No. 25-42) has no dedicated 'change of use' or 'change of occupancy' fee line item -- a full-text review confirmed this.
New residential construction activity
New privately-owned residential construction onlyHousing units authorized by building permits for new privately-owned residential construction — this is not total permit volume (no commercial permits or remodels).
- Latest month (2026-05)
- 22units
22 buildings · $6M valuation
- Trailing 12 months
- 122units
10 of 12 months reported · #47 in Utah coverage by units
- Year to date (2026 YTD through 2026-05)
- 79units
79 buildings · $24.8M valuation
5 month(s) reported to Census
- Full year 2025
- 107units
70 buildings · $39.8M valuation
Source: U.S. Census Bureau, Building Permits Survey (BPS), 2026-05 vintage. Census survey data — separate from the permit-requirements verification above. All Utah building activity
Tips & gotchas
- Tremonton City's Building Department operates independently of Box Elder County — it has its own ordinance (Chapter 1.28), its own fee resolution (No. 25-42), its own Building Inspector contact line ((801) 564-0897), and its own electronic CivicReview permit portal, distinct from the County's own Building Permits/Inspection division that serves unincorporated Box Elder County.
- Tremonton is one of the few Utah jurisdictions in this corpus with an officially published plan-review turnaround time stated in plain text on its own permits page: 'a minimum of 3-5 working days (residential) and 5-7 working days (commercial) for plan reviews and permit processing,' per the City's Building & Solar Permit Requirements page.
- All building permits (residential, commercial, and solar) must be submitted electronically through the City's CivicReview portal (app.civicreview.com) — no paper-only submission path is documented.
- Tremonton's Permit Fee structure is valuation-based (1% of Building Valuation) for new construction, plus a 1%-of-Permit-Fee State Fee, plus a Plan Review Fee (35% of Permit Fee + State Fee for residential/outbuilding; 65% for commercial/industrial/institutional/governmental) — this differs structurally from flat-fee schedules used by some other Utah cities in this corpus (e.g., Murray's per-trade flat fees).
- Flat Miscellaneous Building Inspection Service fees exist for several common trade/limited-scope permits: Re-Roofing $150.00, Water Heater $75.00, Furnace $75.00, Electric Meter $75.00, Mobile/Manufactured Housing $150.00, Small Scale Remodel electrical-only $60.00.
- Building permits expire one (1) year after approval unless the Building Official grants an extension (Tremonton City Code § 1.28.045(A)(3)).
- Sidewalks are a mandatory condition of Certificate of Occupancy along all street frontages (§ 1.28.015) — waivable only via written request to the Land Use Authority Board on neighborhood-character grounds, appealable to the Planning Commission.
- Tremonton's own Building Criteria document (live-checked 2026-07-16, still the same 04/2024 PDF) lists the 2020 NEC as adopted, which is not a valid statewide-adopted edition — Utah Code § 15A-2-103(1)(g) requires the 2023 NEC, unchanged by the 7/1/2026 statewide code transition — confirm the currently enforced electrical code edition directly with the Building Department before relying on the published document for a live project. The same Building Criteria document also still lists 2021 editions of the IBC/IPC/IMC/IFGC/IECC, all of which became 2024 statewide effective 7/1/2026 per § 15A-2-103; IRC (2021) is the one edition in that document that remains accurate.
- Areas of Tremonton without municipal sewer availability require a septic system permitted through the Bear River Health Department (435-257-3318), not the City Building Department.