City of Globe, Arizona has adopted: Arizona has NO statewide mandatory building code for general construction — code adoption is a per-jurisdiction (city/town/county) authority under state enabling statutes (A.R.S. § 9-802 for municipal adoption by reference). The City of Globe independently adopts and administers its own construction codes through its Building Safety Department; it does not defer to Gila County for permitting within city limits. Source: City of Globe Ordinance No. 889 (adopted October 22, 2024), Section 1 and Exhibit A, Section 12-1-4(A).; As of a 2025 industry directory listing (Arizona Building Officials/AZBO), Globe was shown still using the 2003 International Codes and 2002 NEC — this research independently confirmed via the City's own Ordinance No. 889 that Globe has SINCE UPDATED: Ordinance No. 889, adopted by the Mayor and Council on October 22, 2024 (effective per A.R.S. § 9-812, 30 days after publication/posting), repealed the former Article 12-1 'Building Safety Code' and Article 5-2 'Fire Prevention Code' in their entirety and adopted by reference the 2021 edition of the International Building, Residential, Mechanical, Plumbing, Fuel Gas, Energy Conservation, Fire, Property Maintenance, and Existing Building Codes (all ICC), plus the 2021 International Swimming Pool and Spa Code, together with the 2020 National Electrical Code (NFPA 70) — each with City of Globe local amendments. The prior 2003 I-Codes/2002 NEC citation in the AZBO directory is confirmed STALE as of this update; 2021 ICC/2020 NEC is the current, verified code cycle. Source: City of Globe Ordinance No. 889, Recitals and Exhibit A, Section 2 (adopted 10/22/2024, on file at globeaz.gov).; 2021 International Building Code (IBC), published by the International Code Council, Inc., adopted by reference with City of Globe amendments (Ordinance 889, Exhibit A §12-1-8), including adopted Appendix C (Group U — Agricultural Buildings), Appendix F (Rodent Proofing), Appendix H (Signs), and Appendix I (Patio Covers). Exception: detached one- and two-family dwellings and townhouses not more than three stories above grade with a separate means of egress, and their accessory structures, comply with the IRC instead. Source: City of Globe Ordinance No. 889, Exhibit A, Section 12-1-8.; 2021 International Residential Code (IRC) for One- and Two-Family Dwellings, published by ICC, adopted by reference with City of Globe amendments (Ordinance 889, Exhibit A §12-1-9), including adopted Appendices AA, AB, AC, AE (Manufactured Housing Used As Dwellings), AG, AH (Patio Covers), AJ (Existing Buildings and Structures), AQ (Tiny Homes), AU (Cob/Monolithic Adobe Construction), and AW (3D-Printed Building Construction). Source: City of Globe Ordinance No. 889, Exhibit A, Section 12-1-9.; 2021 International Mechanical Code (IMC), adopted by reference with City of Globe amendments, including Appendix A (Chimney Connector Pass-Throughs). Source: City of Globe Ordinance No. 889, Exhibit A, Section 12-1-10.; 2021 International Plumbing Code (IPC), adopted by reference with City of Globe amendments, including Appendix C (Structural Safety 150) and Appendix E (Sizing of Water Piping Systems). Source: City of Globe Ordinance No. 889, Exhibit A, Section 12-1-11.; 2021 International Fuel Gas Code (IFGC), adopted by reference with City of Globe amendments, including Appendices A, B, and C (gas piping sizing and venting systems). Source: City of Globe Ordinance No. 889, Exhibit A, Section 5-1-12 (numbered within Exhibit A as shown in the ordinance).; 2020 National Electrical Code (NEC / NFPA 70), published by the National Fire Protection Association, adopted by reference with limited City of Globe amendments (garage receptacle placement under Article 210.52(G); equipment grounding conductor types under Article 250.118). Source: City of Globe Ordinance No. 889, Exhibit A, Section 12-1-13.; 2021 International Energy Conservation Code (IECC), adopted by reference with City of Globe amendments, including Appendix CB (Solar Ready Zone — Commercial); Climate Zone 2 Maximum Energy Rating Index changed from 52 to 64; RESNET third-party testing/inspection protocol adopted for building envelope, air leakage, and duct tightness testing. Source: City of Globe Ordinance No. 889, Exhibit A, Section 12-1-14.; 2021 International Fire Code (IFC), adopted by reference as the City's uniform fire code with City of Globe amendments, including adopted Appendices B, C, D, E, F, G, H, I, and L; administered by the Globe Fire Department Fire Code Official/Fire Marshal, with the Building Official having equal enforcement authority. Source: City of Globe Ordinance No. 889, Exhibit A, Section 12-1-15.; 2021 International Property Maintenance Code (IPMC), adopted by reference with City of Globe amendments, including Appendix A (Boarding Standards). Source: City of Globe Ordinance No. 889, Exhibit A, Section 12-1-16.; 2021 International Existing Building Code (IEBC), adopted by reference with City of Globe amendments, including Appendix A1 (Seismic Strengthening Provisions for Unreinforced Masonry Bearing Wall Buildings) and Appendix A3 (Prescriptive Seismic Strengthening for Cripple Walls/Sill Plate Anchorage of Light Wood-Frame Residential Buildings). Source: City of Globe Ordinance No. 889, Exhibit A, Section 12-1-17.; 2021 International Swimming Pool and Spa Code (ISPSC), adopted by reference with City of Globe amendments; swimming pool, spa, and hot tub enclosures and safety devices must additionally comply with Arizona Revised Statutes § 36-1681 and Arizona Administrative Code Title 18, Chapter 5 for public/semi-public pools, whichever standard is more restrictive. Source: City of Globe Ordinance No. 889, Exhibit A, Sections 12-1-18 and 101.4.11 (IBC amendment).; ICC A117.1 Accessibility standard, applied together with Arizona Attorney General Administrative Rules R10-3-401 through R10-3-404 (2010 ADA Standards for Accessible Design) and A.R.S. §§ 41-1492 through 41-1492.12 — whichever standard provides the greatest degree of accessibility governs. Source: City of Globe Ordinance No. 889, Exhibit A, Section 1101/1102 (IBC Chapter 11 amendment).; Manufactured homes, mobile homes, factory-built buildings, and Park Model living units require a City of Globe permit for site placement, foundation, skirting/perimeter enclosure, and utility connection (IRC Appendix AE as amended); statewide construction/installation standards for factory-built structures are separately regulated by the Arizona Department of Fire, Building and Life Safety, Office of Manufactured Housing (A.R.S. § 41-4001 et seq.). Source: City of Globe Ordinance No. 889, Exhibit A (IRC Appendix AE amendment); Fee Schedule Resolution No. 1904, Exhibit A (Manufactured Homes fee section).. Local amendments apply — see the City of Globe overview page for the full list.