Change of Occupancy / Change of Use Permit — Murray, Utah · Requirements sheet
Verified 2026-07-22 · Source: https://www.murray.utah.gov/DocumentCenter/View/15111/Change-of-Occupancy-013124
PermitBase is an independent reference and is not affiliated with any government agency. Requirements change and vary by project — confirm current details with the building department before you submit.
Change of Occupancy / Change of Use Permit in Murray, Utah
Murray City's official 'Change of Occupancy' policy implements the International Existing Building Code's change-of-use provisions and IBC 2021 Section 111 (no change of occupancy or re-occupancy without a Certificate of Occupancy issued by the building official). Murray does not publish a distinct standalone fee for a change of occupancy itself — the underlying Building Permit Fees valuation-based table already documented in this jurisdiction's Commercial Building Permit and Commercial Tenant Improvement entries governs any upgrade work the change of use triggers, since a change of occupancy cannot be completed without a building permit for the associated work.
Verified 2026-07-22 · Source
When you need this permit
- No change may be made in the use or occupancy of a building that would place it in a different occupancy division or group unless the building is made to comply with the applicable code requirements for that division/group, subject to the building official's approval of exceptions where the new use is less hazardous than the existing use (per the adopted International Existing Building Code)
- Murray City requires an analysis from a Utah-licensed architect assessing the existing structure to identify existing hazards and determine which components pose a higher relative hazard under the new use
- A change of use to a higher relative hazard must be upgraded to comply with all requirements for the new use
- Per IBC 2021 Section 111, a building or structure (or portion thereof) shall not be used, occupied, or have its occupancy changed until the building official has issued a Certificate of Occupancy
- The architect's analysis must specifically address: means of egress/life safety, heights/areas/type of construction, exterior wall fire-resistance, earthquake safety (structural upgrade if the occupancy category increases per Murray's relative-hazard tables, or if occupant load increases 100% or more), and disabled accessibility
- 20% of the cost of any associated remodel must be expended toward increasing disabled access (which may require accessible toilet rooms and/or other accessible features depending on the extent of the remodel)
- Permits are required for all upgrade work identified by the analysis, and all new work must comply with current construction codes
Required documents
Check off what you have — your progress is saved on this device.
Not ready yet — 0 of 3 required documents checked.
This checker covers one permit. A full project usually triggers several — our paid checklist will assemble all of them, from $29 →
Fee schedule
Review timeline
Inspection process
- 1
Building Inspection Division Review
The Building Inspection Division reviews and comments on the architect's hazard analysis and upgrade plan before permits are issued for the identified work; additional issues may need to be addressed after review, per Murray's official 'Change of Occupancy' policy.
- 2
Final / Certificate of Occupancy
A Certificate of Occupancy or Temporary Certificate of Occupancy is issued once all sign-offs (Building/Electrical/Mechanical/Plumbing, Engineering & SWPP, Fire, Planning/Zoning) are complete, per Murray's Requirements For A Certificate Of Occupancy form — required before the new use may occupy the space, per IBC 2021 Section 111.
See the full Murray inspection guide — scheduling & re-inspection fees →
Tips
- Murray's Change of Occupancy policy requires the architect's analysis to use the policy's own relative-hazard tables (5 tiers for egress/life-safety and exterior-wall fire-resistance; 4 tiers for heights/areas/construction type; distinct tiers for earthquake safety) — these tables differ by analysis category, so a use classified as low-hazard on one table may be higher-hazard on another.
- A change of use to a higher relative-hazard category triggers full new-construction-level compliance for that category (e.g., means of egress under IBC Chapter 10, height/area under Chapters 3-6) — existing conditions are not automatically grandfathered.
- No space may be occupied under its new use, and no change of occupancy may be made, until the building official issues a Certificate of Occupancy (IBC 2021 Section 111) — this applies even if no physical construction work is otherwise required.
- 20% of the cost of any remodel triggered by a change of use must go toward increased disabled access, which may require new accessible toilet rooms or other accessible features depending on the remodel's extent.
- There is no separate 'change of occupancy fee' — budget for the valuation-based Building Permit Fee on whatever upgrade work the architect's analysis identifies, plus the standard $80/hour additional plan review rate if extra review cycles are needed.
Frequently asked questions
Sources & verification
Verified against official sources. Last reviewed 2026-07-22.
Fees, timelines, and adopted codes are researched from each jurisdiction's published records — see how we verify. Requirements change and vary by project, so always confirm the current details with the Murray building department before you submit. PermitBase is an independent reference and is not affiliated with any government agency.
Other permits in Murray
Change of Occupancy / Change of Use Permit in other cities
Compare change of occupancy / change of use permit fees across Utah →
Look up this fee in a different city →
Now live
Build your Murray project checklist
Describe your project once and get every permit, document, and fee it triggers in Murray — in one checklist. Sign up and pay once to generate it, or go unlimited with Pro.
Get started →